1)  ATTENTION! To ensure the safety of people, it is important that you read 

all the following instructions. Incorrect installation or  incorrect use of the 

product  could  cause  serious harm   to people.

  2)  Carefully read the instructions before beginning to install the product.
  3)  Do not  leave packing materials (plastic, polystyrene, etc.)   within  reach 

of  children as  such materials  are  potential  sources  of  danger.

  4)  Store these instructions for  future reference.
  5)  This product was designed and built strictly for the use indicated in this 

documentation. Any other use, not expressly indicated here, could 

compromise the good condition/operation of the product and/or be 

a source of danger.

  6)  FAAC declines all liability caused by improper use or use other than 

that for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the presence 

of  inflammable gas or fumes is a serious danger to safety.

  8)  The mechanical parts must conform to the provisions of Standards EN 

12604 and EN 12605.

    For non-EU countries, to obtain an adequate level of safety, the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

  9)  FAAC is not responsible for failure to observe Good Technique in 

the construction of the closing elements to be motorised, or for any 

deformation that may occur during use.

 10)  The installation must conform to Standards EN 12453 and EN 12445.

     For non-EU countries, to obtain an adequate level of safety, the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

 11)  Before attempting any job on the system, cut out electrical power .
 12)  The mains power  supply of the automated system must be fitted with 

an all-pole  switch with contact opening distance of 3mm or greater. Use 

of a 6A thermal breaker with all-pole circuit break is recommended.

 13)  Make sure that a differential switch with threshold of 0.03 A is fitted 

upstream of the system.

 14)  Make sure that the earthing system is perfectly constructed, and connect 

metal parts of  the means of  the closure to it. 

 15)  The safety devices (EN 12978 standard)  protect any danger areas 

against 

mechanical movement Risks

, such as crushing, dragging, and 

shearing.

 16)  Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended 

for every system, as well as a warning sign adequately secured to the 

frame structure, in addition to the devices mentioned at point “15”.

 17)  FAAC declines all liability as concerns safety and efficient operation of 

the automated system, if system components not produced by FAAC 

are used.

18)   For maintenance, strictly use original parts by FAAC.
 19)  Do  not in any way modify the components of the automated 

system.

 20)  The installer shall supply all information concerning manual operation 

of the system in case of an emergency, and shall hand over to the user 

the warnings handbook supplied with the product.

 21)  Do not allow children or adults to stay near the product while it is 

operating.

 22)  Keep remote controls or other pulse generators away from children, to 

prevent the automated system from being activated involuntarily.

 23)  Transit under the door must occur only when the automated system 

has stopped.

 24)  The user must not attempt any kind of repair or direct action whatever 

and contact qualified personnel only.

 25)  Maintenance: check at least every 6 months the efficiency of the 

system, particularly the efficiency of the safety devices (including, where 

foreseen, the operator thrust force) and of the release devices.

 26)  Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

CE DECLARATION OF CONFORMITY FOR MACHINES

(DIRECTIVE 98/37/EC)

Manufacturer: 

FAAC S.p.A.

Address:

 

Via Benini, 1  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that: 

Operator model. D600 with E600 unit,

 

• is built to be integrated into a machine or to be assembled with other machinery to create a machine under 

the provisions of Directive 98/37/EC;

 

•  conforms to the essential safety requirements of the other following EEC directives:

 

  73/23/EEC and subsequent amendment  93/68/EEC.

 

  89/336/EEC and subsequent amendment  92/31/EEC and 93/68/EEC

 

  Furthermore, the manufacturer declares that the machinery must not be put into service until the machine into 

which it will be integrated or of which it will become a component has been identified and its conformity to the 

conditions of Directive 89/392/EEC and subsequent modifications assimilated in Italian National legislation under 

Presidential Decree No. 459 of 24 July 1996 has been declared.

 

Bologna, 01 January 2006

 

 

 

    The 

Managing 

Director

A. Bassi

Summary of Contents for E600

Page 1: ...00 board components p 10 8 3 Terminal boards and connectors p 10 8 4 DS1 Programming dip switches p 10 8 5 Operating logics p 10 9 COURTESY LIGHT p 11 10 CONNECTIONS p 11 11 PROGRAMMING p 12 11 1 Sett...

Page 2: ...cm install the external control devices at a height of not below 150cm clear of the door movement area but in a position enabling visual control of the area When you have finished installing we advise...

Page 3: ...ing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices mentioned at poi...

Page 4: ...access Do not use them for any other purpose 1 DIMENSIONS 2 TECHNICAL SPECIFICATIONS AUTOMATED SYSTEM D600 3 ANCILLARY ELECTRICAL EQUIPMENT Prepare the electric system in keeping with the instructions...

Page 5: ...oducts but do not use grease and in any event follow the manufacturer s instructions Check correct balance and if the opening mechanical stops have been installed Remove the door s existing closing me...

Page 6: ...g guide until it is near the front terminal the one opposite the drive coupling 3 Assemble the front fitting Fig 7 ref B to the transmission unit Fig 7 ref A 4 Apply slight tension to the chain tighte...

Page 7: ...corresponding to the maximum height reached by the door during movement see Fig 4 3 Position the securing bracket of the front fitting so that the lower edge is at least 5 mm above the intersection po...

Page 8: ...5 Mark drill and secure the fitting to the door using the screws ref Fig 17 NOT supplied Fig 14 Fig 15 Fig 18 Fig 17 Fig 16 8 Lift the sliding guide until the rear fitting is at the same level as the...

Page 9: ...off the ground and cut off the excess section of rope 2 Make a knot at the end of the rope and assemble the release handle Fig 22 3 Pull the release handle down and check if the door can be moved man...

Page 10: ...lse Stop Fsw CLOSED Opens No effect 2 No effect OPENING Locks Locks 2 No effect 1 OPEN Closes No effect 2 No effect 1 CLOSING Reverses motion Locks 2 Reverses motion LOCKED Closes No effect 2 No effec...

Page 11: ...27 If the STOP input is not used jumper connect the input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Input status LEDS The automated system stopped and at...

Page 12: ...However in automatic mode the unit independently determines the movement parameters If the procedure is not correctly concluded e g due to excessive friction during door movement the unit signals a fa...

Page 13: ...establishes the deceleration points Pause time is fixed at 3 minutes MANUAL LEARNING WITH LOGIC A AUTOMATIC Hold down the SETUP push button until the SET UP LED goes on about 5 seconds The SET UP LED...

Page 14: ...ref 5 The relevant LED starts to flash slowly for 5 sec 6 Within these 5 sec while the radio control LED is still flashing press and hold down the required push button on the radio control the radio c...

Page 15: ...ush button flashes for the first 5 sec and then flashes more quickly for the next 5 sec 3 Both LEDs light up on steady beam for 2 sec and then go OFF 4 Release the pressed push button when both LEDs l...

Page 16: ...ntly separating it from the plastic housing Unscrew the 4 screws in the 4 corners of the plastic housing Separate it from the base House the control unit as shown in Fig 36 First hook on the two faste...

Page 17: ...before the manoeuvre is started Learning is not finished correctly and the SET UP LED flashes to signal a fault The automated system frequently reverses motion during the opening and or closing manoeu...

Page 18: ...ns of a transmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the openin...

Page 19: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Page 20: ...D600 D600...

Page 21: ......

Page 22: ...orre dare un nuovo impulso di apertura Se viene rilevato un ostacolo in chiusura nella stessa posizione per tre volte consecutive l automazione assume tale quota come nuova battuta di chiusura e si po...

Page 23: ...oppia fotocellule 2 Dispositivo di comando 1 Dispositivo di comando 2 Radiocomando Lampeggiante Nr Data Descrizione intervento Firme 1 Tecnico Cliente 2 Tecnico Cliente 3 Tecnico Cliente 4 Tecnico Cli...

Page 24: ...ns of a transmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the openin...

Page 25: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Page 26: ...e moteur lectrique qui par l interm diaire de la transmission cha ne ou courroie entra ne la porte en position d ouverture et permet l acc s Si l on a s lectionn le fonctionnement automatique la porte...

Page 27: ...nicien Client Installateur Client Type d installation N de s rie Date d installation Activation COMPOSANT MOD LE N DE SERIE Op rateur Dispositif de s curit 1 Dispositif de s curit 2 Paire de photocell...

Page 28: ...1 wird der Elektromotor in Betrieb gesetzt der das Tor ber einen Ketten oder Riemenantrieb ffnet und Zugang Zufahrt erm glicht Wenn der Automatikbetrieb eingestellt wurde schlie t sich das Tor selbstt...

Page 29: ...hniker Kunde 10 Techniker Kunde Monteur Kunde Art der Anlage Seriennummer Installationsdatum Inbetriebnahme BAUTEIL MODELL SERIENNUMMER Antrieb Sicherheitsvorrichtung 1 Sicherheitsvorrichtung 2 Fotoze...

Page 30: ...impulso para obtener el cierre Un impulso de apertura durante la fase de apertura detiene el movimiento Un impulso de apertura durante la fase de cierre causa siempre la inversi n del movimiento Un i...

Page 31: ...e 10 T cnico Cliente Instalador Cliente Tipo de equipo N de serie Fecha de instalaci n Activaci n COMPONENTE MODELO N DE SERIE Operador Dispositivo de seguridad 1 Dispositivo de seguridad 2 Par de fot...

Page 32: ...ekt en toegang mogelijk maakt Als de automatische werking is ingesteld sluit de deur vervolgens uit zichzelf na de pauzetijd Als tijdens de openingsfase een openingsimpuls wordt gegeven heeft dit geen...

Page 33: ...0 Technicus Klant Installateur Klant Type installatie Serienummer Datum installatie Activering ONDERDEEL MODEL SERIENUMMER Aandrijving Veiligheidsvoorziening 1 Veiligheidsvoorziening 2 Paar fotocellen...

Page 34: ......

Page 35: ...n in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der...

Reviews: