background image

12

 

 

OPEN A

STOP

FSW

SET UP

OPEN A

OPEN B

RADIO SET UP

ENGLISH

11 PROGRAMMING

11.1 Setting the board

Set the unit with Dip-Switch DS1 to obtain the operation you 

require.

11.2 Learning

During the learning procedure, the obstacle detection device 

does not operate. However, the STOP command and the 

closing safety devices (FSW) are enabled; if they are triggered,

learning is interrupted and a fault is signalled.

The SETUP cycle is carried out with the plastic housing 

installed. Just remove the rear door (Fig. 28).

Grip the rear door with both hands and pull gently 

downward. When you have finished the procedure 

described in this chapter, put the door back in place.

The learning cycle makes it possible to define the following:

- the force required to move the door.

- the slow-down points.

- the opening and closing stop points. 

- the pause time (in automatic logic).

Learning must be started with the operator locked, irrespective 

of the door’s position.

The procedure also determines the operating logic.

The logic tables indicate the behaviour of the automated 

system in different conditions, and following commands or 

action by the safety devices.

Learning can be automatic or manual. In the latter case, the 

opening and closing deceleration points can be determined. 

However, in automatic mode, the unit independently determines 

the movement parameters.

If the procedure is not correctly concluded (e.g. due to excessive 

friction during door movement), the unit signals a fault status 

(the SET UP LED flashes slowly). In this case, the procedure must 

be repeated after the cause is eliminated.

AUTOMATIC LEARNING WITH LOGIC “E” (SEMI-AUTOMATIC)

Press the SET UP push-button for one second. 

The SET UP LED starts to flash when you release the 

push-button.

1)   After 8 seconds the operator automatically closes the door

      until the stop point is detected.

2)   The operator begins the opening movement. Wait until the

     stop point is reached, or give an OPEN command in the

       position where you wish to stop motion.

3)   The operator closes the door.

4)   Wait for the door to reach the stop point and for the 

       operator to stop.

If the learning procedure terminated positively, the SET UP LED 

stops flashing and stays lighted for 5 seconds.

Fig. 29

Fig. 28

 Radio signal programming push-button OPEN B.

 RADIO SET UP LED signalling that the OPEN B radio signal is stored in the memory.

 Radio signal programming push-button OPEN A.

 RADIO SET UP LED signalling that the OPEN A radio signal is stored in the memory.

 LED signalling the SET UP stage.

 LED signalling photocells status.

 LED signalling STOP.

 

 LED signalling OPEN A.

 OPEN push-button to totally open sectional door.

 SET UP push-button for programming operating logics and learning work times.

Summary of Contents for E600

Page 1: ...00 board components p 10 8 3 Terminal boards and connectors p 10 8 4 DS1 Programming dip switches p 10 8 5 Operating logics p 10 9 COURTESY LIGHT p 11 10 CONNECTIONS p 11 11 PROGRAMMING p 12 11 1 Sett...

Page 2: ...cm install the external control devices at a height of not below 150cm clear of the door movement area but in a position enabling visual control of the area When you have finished installing we advise...

Page 3: ...ing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices mentioned at poi...

Page 4: ...access Do not use them for any other purpose 1 DIMENSIONS 2 TECHNICAL SPECIFICATIONS AUTOMATED SYSTEM D600 3 ANCILLARY ELECTRICAL EQUIPMENT Prepare the electric system in keeping with the instructions...

Page 5: ...oducts but do not use grease and in any event follow the manufacturer s instructions Check correct balance and if the opening mechanical stops have been installed Remove the door s existing closing me...

Page 6: ...g guide until it is near the front terminal the one opposite the drive coupling 3 Assemble the front fitting Fig 7 ref B to the transmission unit Fig 7 ref A 4 Apply slight tension to the chain tighte...

Page 7: ...corresponding to the maximum height reached by the door during movement see Fig 4 3 Position the securing bracket of the front fitting so that the lower edge is at least 5 mm above the intersection po...

Page 8: ...5 Mark drill and secure the fitting to the door using the screws ref Fig 17 NOT supplied Fig 14 Fig 15 Fig 18 Fig 17 Fig 16 8 Lift the sliding guide until the rear fitting is at the same level as the...

Page 9: ...off the ground and cut off the excess section of rope 2 Make a knot at the end of the rope and assemble the release handle Fig 22 3 Pull the release handle down and check if the door can be moved man...

Page 10: ...lse Stop Fsw CLOSED Opens No effect 2 No effect OPENING Locks Locks 2 No effect 1 OPEN Closes No effect 2 No effect 1 CLOSING Reverses motion Locks 2 Reverses motion LOCKED Closes No effect 2 No effec...

Page 11: ...27 If the STOP input is not used jumper connect the input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Input status LEDS The automated system stopped and at...

Page 12: ...However in automatic mode the unit independently determines the movement parameters If the procedure is not correctly concluded e g due to excessive friction during door movement the unit signals a fa...

Page 13: ...establishes the deceleration points Pause time is fixed at 3 minutes MANUAL LEARNING WITH LOGIC A AUTOMATIC Hold down the SETUP push button until the SET UP LED goes on about 5 seconds The SET UP LED...

Page 14: ...ref 5 The relevant LED starts to flash slowly for 5 sec 6 Within these 5 sec while the radio control LED is still flashing press and hold down the required push button on the radio control the radio c...

Page 15: ...ush button flashes for the first 5 sec and then flashes more quickly for the next 5 sec 3 Both LEDs light up on steady beam for 2 sec and then go OFF 4 Release the pressed push button when both LEDs l...

Page 16: ...ntly separating it from the plastic housing Unscrew the 4 screws in the 4 corners of the plastic housing Separate it from the base House the control unit as shown in Fig 36 First hook on the two faste...

Page 17: ...before the manoeuvre is started Learning is not finished correctly and the SET UP LED flashes to signal a fault The automated system frequently reverses motion during the opening and or closing manoeu...

Page 18: ...ns of a transmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the openin...

Page 19: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Page 20: ...D600 D600...

Page 21: ......

Page 22: ...orre dare un nuovo impulso di apertura Se viene rilevato un ostacolo in chiusura nella stessa posizione per tre volte consecutive l automazione assume tale quota come nuova battuta di chiusura e si po...

Page 23: ...oppia fotocellule 2 Dispositivo di comando 1 Dispositivo di comando 2 Radiocomando Lampeggiante Nr Data Descrizione intervento Firme 1 Tecnico Cliente 2 Tecnico Cliente 3 Tecnico Cliente 4 Tecnico Cli...

Page 24: ...ns of a transmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the openin...

Page 25: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Page 26: ...e moteur lectrique qui par l interm diaire de la transmission cha ne ou courroie entra ne la porte en position d ouverture et permet l acc s Si l on a s lectionn le fonctionnement automatique la porte...

Page 27: ...nicien Client Installateur Client Type d installation N de s rie Date d installation Activation COMPOSANT MOD LE N DE SERIE Op rateur Dispositif de s curit 1 Dispositif de s curit 2 Paire de photocell...

Page 28: ...1 wird der Elektromotor in Betrieb gesetzt der das Tor ber einen Ketten oder Riemenantrieb ffnet und Zugang Zufahrt erm glicht Wenn der Automatikbetrieb eingestellt wurde schlie t sich das Tor selbstt...

Page 29: ...hniker Kunde 10 Techniker Kunde Monteur Kunde Art der Anlage Seriennummer Installationsdatum Inbetriebnahme BAUTEIL MODELL SERIENNUMMER Antrieb Sicherheitsvorrichtung 1 Sicherheitsvorrichtung 2 Fotoze...

Page 30: ...impulso para obtener el cierre Un impulso de apertura durante la fase de apertura detiene el movimiento Un impulso de apertura durante la fase de cierre causa siempre la inversi n del movimiento Un i...

Page 31: ...e 10 T cnico Cliente Instalador Cliente Tipo de equipo N de serie Fecha de instalaci n Activaci n COMPONENTE MODELO N DE SERIE Operador Dispositivo de seguridad 1 Dispositivo de seguridad 2 Par de fot...

Page 32: ...ekt en toegang mogelijk maakt Als de automatische werking is ingesteld sluit de deur vervolgens uit zichzelf na de pauzetijd Als tijdens de openingsfase een openingsimpuls wordt gegeven heeft dit geen...

Page 33: ...0 Technicus Klant Installateur Klant Type installatie Serienummer Datum installatie Activering ONDERDEEL MODEL SERIENUMMER Aandrijving Veiligheidsvoorziening 1 Veiligheidsvoorziening 2 Paar fotocellen...

Page 34: ......

Page 35: ...n in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der...

Reviews: