E045S
20
532373 - Rev.A
6
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
BUS 2EASY STATUS
To verify the BUS 2easy connection, check the 2EASY
LEDs on the board:
BUS MON
At least one device is in operation
NO devices in operation
BUS
OK
SLEEPING
SHORT CIRCUIT
ERROR
The status of the BUS 2easy is also shown in the
bu
function in Basic Programming:
no
No device registered
-
At least one device registered
cc
BUS 2easy line short-circuited
Er
BUS 2easyline error
BUS 2EASY DEVICE REGISTRATION
Registration is required:
-
when the automation system is first started or after
the board has been replaced
-
following any changes (addition, replacement or
removal) to the BUS 2easy devices
Registration procedure:
The SETUP procedure registers the BUS 2easy devices
that are connected. Alternatively, you can carry out
the following procedure.
1. With the board powered, go to the
bu
function
in basic programming. If there are no devices
registered,
no
will appear on the display, otherwise
segment 13 will be lit (
Press the
++
and
--
simultaneously for at least 5 s.
The display flashes, then
Y
appears (registration
complete).
2. Release the buttons.
3. Exiting from programming mode.
CHECKING THE BUS 2EASY DEVICES
1. Select parameter
bu
in basic programming. If
there are no devices registered,
no
will appear
on the display, otherwise segment 13 will be lit.
This menu can be used to check the operation of
the registered devices: activate each device and
check that the corresponding segment lights up
2. Press and hold the
++
button and keep it pressed;
the segments relative to the registered devices
will come on. Each segment of the display cor-
responds to a type of device:
8.
8.
13
5
12
11
1
2
14
7
6
8
10
3
4
9
1
Open A control device
2
Open B control device
3
Closing photocells
4
Photocells for Open impulse
5
Opening/closing photocells
6
Close control device
7
Opening photocells
8
Stop control device
9
Closing sensitive edge
10
Encoder - leaf 2
11
Not used
12
Opening sensitive edge
13
BUS 2easy status
14
Encoder - leaf 1