Rev. 01.2006 - Istallation Manual
B
C
D
F
E
B
F
A
2
ELECTRICAL CONNECTIONS
2.1
ELECTRICAL SYSTEM LAY-OUT
A) Control board enclosure
B) Pull boxes (not supplied)
C) 3x1.5 mm²(2+T) 230V
D) Key-operated selector switch
OPTIONAL
E) Flashing lamp 12 volt
OPTIONAL
F) Infrared photocells OPTIONAL
Notes:
1) To lay the electrical cables,
use adequate rigid and/or
flexible sheaths.
2) The figure shows an example
of connection to the
DOMOLINK operator. This
connection layout can be
used also for DOMOSWING.
2.2
DESCRIPTION OF CONTROL UNITS
2.2.1
TECHNICAL SPECIFICATIONS
SINGLE MULTI-FUNCTION CONTROL BOARD
Power supply voltage
of the toroidal transformer:
230V - 50/60Hz
Power supply voltage
of the control unit:
13V - 50/60Hz
Absorbed power:
7 W
Motor max. load:
50 W (per motor)
Accessories max. load
12 Vdc 150mA
Flashing light max. load:
12 Vdc 21W max.
Operating temperature:
-20°C / +55°C
Protective fuse:
2
Function logics:
Automatic/
Step-by-step
automatic /
Step-by-step
semiautomatic.
Programming of functions:
By Dip-Switch.
Work time:
Self-learning during programming.
Pause time:
Self-learning during programming.
Leaf closing delay:
Two preset levels.
Adjustment of motor force:
Two preset levels.
Specifications of toroidal transformer 230V~:
Primary 230V~ / sec.13V~ / 150VA
Slow-downs:
At opening and closing during self-learning.
Clutch device:
Electronic clutch adjustable on two preset levels.