Rev. 01.2006 - Istallation Manual
2.5.4
OPERATING LOGICS
(1)
The operation described in the tables is obtained if the STOP input is enabled (dip-switch 6 = OFF).
When the input is disabled, the command has no effect.
(2)
The operation described in the tables is obtained if the input of the photocells is enabled (dip-switch 7
= OFF). When the input is disabled, the command has no effect.
(3)
In single motor installations, partial opening of the gate corresponds to about 60% of the memory
stored opening. In two-motor installations, partial opening corresponds to the total opening of the leaf
on which motor M1 is installed.
AUTOMATIC LOGIC (DIP-SWITCH 2=ON / DIP-SWITCH 3=OFF
GATE STATUS
PULSES
Closed
Open in pause
Closing
Opening
OPEN A
Opens leaves and re-
closes after pause time
Closes at once
Reverses gate movement
No effect
OPEN B
Partially opens the gate
(3)
Closes at once
No effect
No effect
STOP
(1)
Disables OPEN commands
Stops pause time count
Stops operation
Stops operation
PHOTOCELLS
(2)
No effect
Stops operation and on
release, if pause time
exceeded, closes after 5
sec
Reverses motion
No effect
STEP-BY-STEP AUTOMATIC LOGIC (DIP-SWITCH 2=ON / DIP-SWITCH 3=ON
GATE STATUS
PULSES
Closed
Open in pause
Closing
Opening
OPEN A
Opens leaves and re-
closes after pause time
Closes at once
Stops gate motion and,
at next pulse, opens
Stops gate motion and,
at next pulse, closes
OPEN B
Partially opens the gate
(3)
Closes at once
No effect
No effect
STOP
(1)
Disables OPEN commands
Stops pause time count
Stops operation
Stops operation
PHOTOCELLS
(2)
No effect
Stops operation and on
release, if pause time
exceeded, closes after 5
sec.
Reverses motion
No effect
SEMIAUTOMATIC LOGIC (DIP-SWITCH 2=OFF / DIP-SWITCH 3=OFF
GATE STATUS
PULSES
Closed
Open
Closing
Opening
OPEN A
Opens leaves
Closes at once
Reverses gate movement
Reverses gate movement
OPEN B
Partially opens the gate
(3)
Closes at once
No effect
No effect
STOP
(1)
Disables OPEN commands
Stops operation
Stops operation
Stops operation
PHOTOCELLS
(2)
No effect
On release, closes after 5
sec.
Reverses motion
No effect
SEMIAUTOMATIC STEP-BY-STEP LOGIC (DIP-SWITCH 2=OFF / DIP-SWITCH 3=ON
GATE STATUS
PULSES
Closed
Open
Closing
Opening
OPEN A
Opens leaves
Closes at once
Stops gate movement
and, at next pulse, opens
Stops gate movement
and, at next pulse,
closes
OPEN B
Partially opens the gate
(3)
Closes at once
No effect
No effect
STOP
(1)
Disables OPEN commands
Stops operation
Stops operation
Stops operation
PHOTOCELLS
(2)
No effect
On release, closes after 5
sec.
Reverses motion
No effect