background image

4

200

145

2168 / 2768 / 3368

360

ENGLISH

The level of noise emission of operator D1000, referred 

to the work station, is 52 dB(A).

These instructions apply to model 

FAAC D1000

.

The D1000 automated systems make it possible to automate 

balanced sectional doors of single garages for residential 

use.

They consist of an electro-mechanical operator, electronic 

control unit and courtesy light built into a single unit. This unit is 

fitted to the ceiling and opens the door by means of a transmission 

chain or belt.

The system is non-reversing and, therefore, the door locks 

mechanically when the motor is not operating and, consequently, 

no lock is necessary; two manual releases, one on the inside 

and one on the outside (optional) make it possible to move the 

door in case of a power cut or fault.

The operator is supplied with an electronic device that detects 

the presence of an obstacle that would hinder door movement 

-  the device prevents crushing or lifting. 

This instruction refers to the operator with chain drive, but the 

same procedures, regulations and application limits apply also 

to the belt driven operator.

The D1000 automated systems were designed and built for 

indoor use and to control vehicle access. Do not use them for 

any other purpose.

1.  DIMENSIONS 

2. TECHNICAL SPECIFICATIONS

AUTOMATED SYSTEM D1000

3. ANCILLARY ELECTRICAL EQUIPMENT

Prepare the electric system in keeping with the instructions in 

the chapter entitled “Warnings for the installer”.

When you have finished installing, check if any external pipes 

or cables can come into contact with moving parts. 

Install the fixed control points at a minimum height of 150 cm, 

clear of the door movement area, but in a position enabling 

visual control of that area.

  Cable 2 x 0.5 mm

2

 (TX photocell)

 

Cable 4 x 0.5 mm

2

 (RX photocell)

  Power pipe (230V)

  Low voltage pipe

 

Cable 2 x 1.5 mm

2

 (power)

Fig. 2

Dimensions in mm.

Fig. 1

Model

D1000

Power supply (V ~ / 50 Hz.)

230

Electric motor (Vdc)

24

Maximum absorbed power (W)

350

Thrust force (N)

600/1000

Type of use

continuous

Maximum dimensions from ceiling (mm)

35 (Fig. 4)

Courtesy light (V ~/W)

230 / 40 max.

Courtesy light timer (sec)

120

Standard speed with no-load carriage (m/min)

8,9

Slow speed with no-load carriage (m/min)

4,5

Carriage deceleration speed (m/min)

1,1

Noise at standard speed (dB(A))

52

Travel length at deceleration

Varies according to set-up

Intrinsic safety device 

Category 2

Maximum sectional door width (mm)

5000

Maximum sectional door  height (mm)

See useful travel

Sliding guide useful travel (mm)

2500 - 3100 - 3800

Protection class

For indoor use only (IP20)

Operating ambient temperature (°C)

-20 / +55

Summary of Contents for D1000

Page 1: ...D1000 D1000...

Page 2: ...ur les remarques concernant les caract ristiques ou le fonctionnement du produit Vor der Installation des Produkts sind die Anweisungen vollst ndig zu lesen Mit dem Symbol sind wichtige Anmerkungen f...

Page 3: ...board components p 10 8 3 Terminal boards and connectors p 10 8 4 DS1 Programming dip switches p 10 8 5 Operating logics p 10 9 COURTESY LIGHT p 11 10 CONNECTIONS p 11 11 PROGRAMMING p 12 11 1 Settin...

Page 4: ...install the external control devices at a height of not below 150cm clear of the door movement area but in a position enabling visual control of the area When you have finished installing we advise y...

Page 5: ...ng 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices mentioned at poin...

Page 6: ...ccess Do not use them for any other purpose 1 DIMENSIONS 2 TECHNICAL SPECIFICATIONS AUTOMATED SYSTEM D1000 3 ANCILLARY ELECTRICAL EQUIPMENT Prepare the electric system in keeping with the instructions...

Page 7: ...ducts but do not use grease and in any event follow the manufacturer s instructions Check correct balance and if the opening mechanical stops have been installed Remove the door s existing closing mec...

Page 8: ...g guide until it is near the front terminal the one opposite the drive coupling 3 Assemble the front fitting Fig 7 ref B to the transmission unit Fig 7 ref A 4 Apply slight tension to the chain tighte...

Page 9: ...corresponding to the maximum height reached by the door during movement see Fig 4 3 Position the securing bracket of the front fitting so that the lower edge is at least 5 mm above the intersection po...

Page 10: ...5 Mark drill and secure the fitting to the door using the screws ref Fig 17 NOT supplied Fig 14 Fig 15 Fig 18 Fig 17 Fig 16 8 Lift the sliding guide until the rear fitting is at the same level as the...

Page 11: ...80 cm off the ground and cut off the excess section of rope 2 Make a knot at the end of the rope and assemble the release handle Fig 22 3 Pull the release handle down and check if the door can be move...

Page 12: ...LOCKED Closes No effect 2 No effect 1 Supply voltage V Hz 230 50 Power supply to accessories Vdc 24 Accessories max load mA 200 Operating ambient temperature C 20 55 Quick fit connector for receiver b...

Page 13: ...he input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Inputs status leds The automated system stopped and at rest is indicated in bold for each input STOP 1...

Page 14: ...rent conditions and following commands or action by the safety devices Learning can be automatic or manual In the latter case the opening and closing deceleration points can be determined However in a...

Page 15: ...UP LED starts to flash when you release the push button Start the following procedure within 4 seconds otherwise the operator will perform automatic SET UP 1 Give the 1st OPEN command the operator pe...

Page 16: ...ond and then goes OFF indicating that storage was executed 6 To add other radio controls set the same ON OFF combination used in point 1 12 2 Memory storage of radio controls SLH A Maximum of 250 code...

Page 17: ...EN A or OPEN B 5 The LED on the board relating to the channel being learned flashes for 5 sec within which time the code of another radio control must be transmitted 6 The LED lights up on steady beam...

Page 18: ...4 Fig 36 Fig 37 17 3 Safety edge CN60E The use of the safety edge with conductive element is facilitated because the control unit Fig 36 ref can be housed on board the operator Procedure Grip the rear...

Page 19: ...ently reverses motion during the opening and or closing manoeuvre The automated system detects that the door movement is too difficult If you are using manual adjustment of force thesetthrustcouldbein...