8.3. Terminal-boards and connectors

8.2. E1000 board components 

8.  E1000 CONTROL BOARD

8.1. Technical specifications

Fig. 25

8.4. DS1 Programming dip-switches

8.5. Operating logics

Logic A (automatic)

Logic E (semi-automatic)

Description

Connected device

OPEN A

Command device with N.O. contact

(see chap. OPERATING LOGICS)

STOP

Device with N.C. contact which stops the 

automated system

Negative for OPEN A and STOP devices

FSW

Closing safety device with N.C. contact (see 

chap. OPERATING LOGICS)

LAMP

OPEN COLLECTOR 24 Vdc 100 mA. output for 

flashing lamp

-TX FSW

Negative for powering safety accessories (FAIL 

SAFE function)

Negative for powering accessories 

+24 Vdc for powering accessories 

No. Function

OFF

ON

1 Fail Safe

Enabled

Not enabled

2 Anti-crushing sensitivity

Low

High

3 Force adjustment 

Automatic

Manual

4 Carriage speed

High

Low

Status

Open (pulse)

Stop

Fsw

CLOSED

Opens and closes 

after pause time

No effect (2)

No effect 

OPENING

No effect 

Locks  (2)

No effect  (1)

OPEN IN 

PAUSE

Resumes counting of 

pause time (1)

Locks  (1)

Resumes counting of 

pause time (1)

CLOSING

Reverses motion

Locks (2)

Reverses motion

LOCKED

Closes

No effect  (2)

No effect  (1)

Status

Open (pulse)

Stop

Fsw

CLOSED

Opens

No effect (2)

No effect 

OPENING

Locks

Locks (2)

No effect  (1)

OPEN

Closes

No effect  (2)

No effect  (1)

CLOSING

Reverses motion

Locks (2)

Reverses motion

LOCKED

Closes

No effect  (2)

No effect  (1)

Supply voltage (V ~ / Hz.)

230 / 50

Power supply to accessories (Vdc)

24

Accessories max. load (mA.)

200

Operating ambient temperature (°C)

-20 / +55

Quick-fit connector

for receiver boards XF433 / 

XF868 and battery module

Operating logics

Automatic / Semiautomatic 

Terminal-board connections

Open/Stop/Safety devices/Fail-

safe/Flashing lamp 24 Vdc

Courtesy light timer (min.)

2

Fail Safe

If activated, it enables the photocell operating test before every 

movement.

Operating logics

For doors with an irregular movement, it reduces the sensitivity of 

the anti-crushing device to prevent unwanted action by it.

Manual adjustment of force

If you wish to adjust force manually, before learning, turn ON 

switch No. 3 of DS1, and manually adjust the thrust force with TR1 

(closure) and TR2 (opening). Maximum available thrust is 1000N.

J1

Low voltage inputs/accessories  terminal board

J2

Quick-fit connector for receivers XF433 or XF868

J3

230V power supply input terminal board 

J4

Connector for transformer primary winding

J5

Courtesy light terminal-board

J7

Connector for transformer secondary winding

J8

Motor output connector

J12

Battery module connector 

OPEN A

Radio signal programming push-button

OPEN B

Radio signal programming push-button

OPEN

OPEN push-button

SETUP

SET-UP push-button

DS1

Programming dip-switch

LD1

Signalling LED: OPEN input

LD2

Signalling LED: STOP input

LD3

Signalling LED: FSW input

LD4

Signalling LED: SET UP cycle

LD5

LED signalling memory-storage: radio channel OPEN A

LD6

LED signalling memory-storage: radio channel OPEN B

TR1

Closing force adjustment

 

TR2

Opening force adjustment 

Summary of Contents for D1000

Page 1: ...D1000 D1000...

Page 2: ...ur les remarques concernant les caract ristiques ou le fonctionnement du produit Vor der Installation des Produkts sind die Anweisungen vollst ndig zu lesen Mit dem Symbol sind wichtige Anmerkungen f...

Page 3: ...board components p 10 8 3 Terminal boards and connectors p 10 8 4 DS1 Programming dip switches p 10 8 5 Operating logics p 10 9 COURTESY LIGHT p 11 10 CONNECTIONS p 11 11 PROGRAMMING p 12 11 1 Settin...

Page 4: ...install the external control devices at a height of not below 150cm clear of the door movement area but in a position enabling visual control of the area When you have finished installing we advise y...

Page 5: ...ng 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices mentioned at poin...

Page 6: ...ccess Do not use them for any other purpose 1 DIMENSIONS 2 TECHNICAL SPECIFICATIONS AUTOMATED SYSTEM D1000 3 ANCILLARY ELECTRICAL EQUIPMENT Prepare the electric system in keeping with the instructions...

Page 7: ...ducts but do not use grease and in any event follow the manufacturer s instructions Check correct balance and if the opening mechanical stops have been installed Remove the door s existing closing mec...

Page 8: ...g guide until it is near the front terminal the one opposite the drive coupling 3 Assemble the front fitting Fig 7 ref B to the transmission unit Fig 7 ref A 4 Apply slight tension to the chain tighte...

Page 9: ...corresponding to the maximum height reached by the door during movement see Fig 4 3 Position the securing bracket of the front fitting so that the lower edge is at least 5 mm above the intersection po...

Page 10: ...5 Mark drill and secure the fitting to the door using the screws ref Fig 17 NOT supplied Fig 14 Fig 15 Fig 18 Fig 17 Fig 16 8 Lift the sliding guide until the rear fitting is at the same level as the...

Page 11: ...80 cm off the ground and cut off the excess section of rope 2 Make a knot at the end of the rope and assemble the release handle Fig 22 3 Pull the release handle down and check if the door can be move...

Page 12: ...LOCKED Closes No effect 2 No effect 1 Supply voltage V Hz 230 50 Power supply to accessories Vdc 24 Accessories max load mA 200 Operating ambient temperature C 20 55 Quick fit connector for receiver b...

Page 13: ...he input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Inputs status leds The automated system stopped and at rest is indicated in bold for each input STOP 1...

Page 14: ...rent conditions and following commands or action by the safety devices Learning can be automatic or manual In the latter case the opening and closing deceleration points can be determined However in a...

Page 15: ...UP LED starts to flash when you release the push button Start the following procedure within 4 seconds otherwise the operator will perform automatic SET UP 1 Give the 1st OPEN command the operator pe...

Page 16: ...ond and then goes OFF indicating that storage was executed 6 To add other radio controls set the same ON OFF combination used in point 1 12 2 Memory storage of radio controls SLH A Maximum of 250 code...

Page 17: ...EN A or OPEN B 5 The LED on the board relating to the channel being learned flashes for 5 sec within which time the code of another radio control must be transmitted 6 The LED lights up on steady beam...

Page 18: ...4 Fig 36 Fig 37 17 3 Safety edge CN60E The use of the safety edge with conductive element is facilitated because the control unit Fig 36 ref can be housed on board the operator Procedure Grip the rear...

Page 19: ...ently reverses motion during the opening and or closing manoeuvre The automated system detects that the door movement is too difficult If you are using manual adjustment of force thesetthrustcouldbein...

Reviews: