background image

1.

DESCRIPTION

The FAAC BILAMP accessory is a luminous signalling device
comprising a white courtesy lamp with 150-second timer
and an intermittent yellow flashing light.
It may be utilised either externally, positioned on pillars or
posts, or internally installed in garages, passageways, etc.

1.1 TECHNICAL SPECIFICATIONS

Table 1: FAAC BILAMP specifications

Supply voltage

230 V~ ( +6%  -10%)  50 Hz

Input

50 W

Degree of protection

IP55

Lamp

Miniature ball E27 230V/25W

Max load of lamp

25W

Ambient temperature

-20 °C +55 °C

Terminal block inputs

Power supply / Timer start

Connector

Courtesy lamp

1.2 LAY-OUT

a

a

a

a

a

 J1 Terminal block:

 Courtesy-lamp power supply and

Start control - see fig.5.

b

b

b

b

b

 

J2 Terminal block:

 Courtesy-lamp power supply, max.

25W.

c

c

c

c

c

 

Luminous

 intermittent signal lamp (FAACLAMP), max.

25W.

2.

 BILAMP INSTALLATION

Warning: before carrying out any type of operation on the
FAAC BILAMP luminous signalling device

 

(connections,

maintenance), always disconnect the electrical power
supply.

1) Determine the installation point of the FAAC BILAMP

luminous device, by checking that the signal lamp is
fully visible from both inside and outside the property.
There are two possible installation solutions:
- Wall positioning (fig.1);
- Floor positioning (fig.2).
The FAAC BILAMP luminous device allows optional fitting
of the receiver (see paragraph 3).
In such case a multicore cable with three .5 mm

2

conductors will be required for the connection of the
receiver.

NB: Do not use the same multicore cable for connecting
the receiver and the luminous signalling device.

However, in order to avoid any electrical disturbance, it
is preferable to use separate sheathing or shielded
cable for connecting the receiver.

2) Secure the support of the device using screws or screw

anchors.

2

1

3

NB: Before carrying out such operation, channel the
electric cable/s into the special hole machined from
the base of the support (fig. 1/2).

3) Prepare the cables for connection to the electronic

board.
Cable diameter should be not less than 1 mm

2

.

In order to facilitate wiring operations, make the cable
trail from the wall  (or floor) by about 25cm.

4) Using a Philips screwdriver, remove the yellow and white

covers of the FAAC BILAMP (fig.3).

5) Remove the luminous signal lamps.
6) Remove the diaphragm (A) situated on the opposite

side of the arrow engraved on the body of the luminous
device (fig.4).

7) Effect the wiring on the FAAC BILAMP card and the

electronic board as per fig. 5, respecting the polarity
engraved on the card.

8) Refit everything.

3.

RECEIVER INSTALLATION

The body of the luminous device is designed to allow
optional fitting of a receiver.
In such case, proceed as follows:
1) Pierce the diaphragm as per fig.6.
2) Channel the cable and insert the device into the

support by pressing the two coupling tabs, as per fig. 7.

3) Insert the supplied lower door into the luminous signalling

device, as per fig. 8.

4) Insert the electric cables into the receiver support.

Secure the receiver support using the screws supplied
as shown in fig.8

5) Effect the wiring.

4.

MAINTENANCE

The FAAC LAMP is fitted with two lamps that can be
accessed by removing the respective side cover, (fig. 3).
Replace the faulty component with a similar one, as
detailed by the specifications, table1
The fitting of lamps with a greater rating than that requested
can cause irreparable damage to the electronic circuit
situated inside the FAAC BILAMP luminous signalling device.

7

ENGLISH

ENGLISH

Summary of Contents for BILAMP

Page 1: ...Z I E N D A C E R TIF I C A T A UNI EN ISO 9001 085 para la naturaleza 100 papel reciclado ist umweltfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 carta rici...

Page 2: ...2 230V 6 10 50Hz A 1 APP ELETTRONICA N morsetto CONTROL UNIT Terminal number COFFRET ELECTRONIQUE N Borne STEUERUNGE Klemme Nr EQUIPO ELECTRONICO N Borne 410 MPS 450 MPS 460 P 624 MPS 746 MPS 748 MP 8...

Page 3: ...ILAMP complies with the essential safety requirements of the following directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendment 92 31 EEC and 93 68 EEC Additional no...

Page 4: ...for the installation with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 13 Ensure that there is a differential switch up l...

Page 5: ...s preferable to use separate sheathing or shielded cable for connecting the receiver 2 Secure the support of the device using screws or screw anchors 2 1 3 NB Before carrying out such operation channe...

Page 6: ...t conforme aux r gles de s curit vis es par les directives suivantes 73 23 CEE modifi e 93 68 CEE 89 336 CEE modifi e 92 31 CEE et 93 68 CEE Remarque suppl mentaire Ces produits ont t soumis un test d...

Page 7: ...3 mm En alternative il est recommand l emploi d un interrupteur magn to thermique de 6 A de calibre avec coupure omnipolaire 13 V rifier la pr sence en amont de l installation lectrique d un interrup...

Page 8: ...pteur 2 1 3 2 Fixer le support du dispositif avec des vis ou des chevilles expansion Nota bene Avant d effectuer cette op ration faire passer le s c ble s lectrique s dans le trou sur la base du suppo...

Page 9: ...e a poner al d a la presente publicaci n todas las modificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial...

Reviews: