A1400 AIR RDT
90
532119 04 - Rev. C
OK
OK
OK
OK
OK
OK
OK
ENGLISH
ITALIANO
FRANÇAIS
DEUTSCH
ESPANOL
NEDERLANDS
Tr
ansla
tion of the original instruc
tions
ENGLISH
MENU 1 LANGUAGE
Default: ITALIANO
--
16 Night-time
16 Night-time
--
17 Manual
17 Manual
3. If the input has not been disabled, select the logic:
-
Normally open (NO)
-
Normally closed (NC)
4. If an input with CLOSURE SAFETY function has been selected, set
the TEST:
-
Enabled
-
Disabled (Default)
5. Repeat the procedure for the other inputs.
2 Outputs O1 / O2
1. Select an output. The complete list with relevant default is:
-
O1
Gong
-
O2 Door not closed
2. Select function:
-
0 Disabled
-
1 Gong
-
2 Error
-
3 Battery
-
4 Emergency active
-
5 Test (for I1,I2,I3 and I4)
-
6 Door not closed
-
7 Door open
-
8 Door in motion
-
9 Light*
-
10 Intrusion active
(* ) If this function is selected, set the time:
-
from 1s to 255s (Default 60s)
3. If the output has not been disabled, select the logic:
-
Normally open (NO)
-
Normally closed (NC)
4. Repeat the procedure for the other output.
3 Safety devices S1-S4
1. Select a SAFETY input. The complete list with relevant default is:
-
S1 DISABLED
-
S2 DISABLED
-
S3 CLOSING SAFETY / TEST ENABLED / NC
-
S4 CLOSING SAFETY / TEST ENABLED / NC
2. Select function:
-
Disabled
-
Closing safety
-
Opening safety
3. If the input has not been disabled, set the TEST:
-
Enabled
-
Disabled
4. If the input has not been disabled, select the logic:
-
Normally open (NO)
-
Normally closed (NC)
5. Repeat the procedure for the other inputs.
4 Sensors I / E
1. Select a sensor. The complete list with relevant default is:
-
SENSOR I Internal current
-
SENSOR E External contact NO
2. Select the function for Sensor I (Internal Sensor):
-
Internal current
-
Internal frequency
-
Disabled
3. Select the function for Sensor E (External Sensor):
-
Disabled
1
LANGUAGE
MENU 2 PROGRAMMING
The menu is only accessible if the INSTALLER password has been
entered.
If a different password has been inserted, it is indicated: MENU
RESERVED FOR INSTALLERS.
The list is:
-
1 INPUTS / OUTPUTS
-
2 MOTION
-
3 TIMING
-
4 ENERGY SAVING
-
5 BATTERY KIT
-
6 MOTOR BLOCK KIT
-
7 INSTALLATION
-
8 SUNDRIES
-
9 LOG
■
INPUTS / OUTPUTS
OK
OK
INPUTS / OUTPUTS
2
PROGRAMMING
1 Inputs I1- I4
1. Select an input. The complete list with relevant default is:
-
I1 OPEN AUTOMATIC / NO
-
I2 OPEN EXTERNAL / NO
-
I3 KEY / NO
-
I4 OPEN SEMI-AUTOMATIC / NO
2. Select function:
--
0 Disabled
0 Disabled
--
1 Open total
1 Open total
--
2 Open external
2 Open external
--
3 Exit only
3 Exit only
--
4 = Open automatic
4 = Open automatic
--
5 = Open semi-automatic
5 = Open semi-automatic
--
6 Pharmacy
6 Pharmacy
--
7 Key
7 Key
--
8 Closure safety
8 Closure safety
--
9 Open internal
9 Open internal
--
12 Timer
12 Timer
--
13 Partial
13 Partial
--
14 Opening safety
14 Opening safety