A1400 AIR RDT
73
532119 04 - Rev. C
Tr
ansla
tion of the original instruc
tions
ENGLISH
15. DIAGNOSTICS AND PROCEDURES
14
Statuses of the automation
Status of the automation
00
00
CLOSED
01
01
in OPENING
02
02
OPEN
03
03
in PAUSE
04
04
in NIGHT-TIME PAUSE
05
05
in CLOSING
06
06
OPEN in EMERGENCY
07
07
in MANUAL mode
08
08
in NIGHT-TIME mode
09
09
Opening with Auxiliary_motor
10
10
System TEST in progress
11
11
STAND-BY
12
12
Safety TEST in progress
13
13
OPEN in ERROR (Press simultan and - to display the active
ERROR)
(
*
)
L0-L2
L0-L2
PHASES L0, L1, L2 of SETUP in progress (flashing)
(
*
)
Status
13
13
is caused by an error which stops the door in open status and prevents
closure. To restore operation, remove the cause and perform a RESET.
15.1 ACOUSTIC SIGNAL
When the time set for the maintenance to be performed elapses, the
control board beeps at each closure indicating a maintenance request:
3s
The maintenance request is set by default upon reaching the MAX
number of cycles: 1 000 000.
With SDK EVO it is possible to:
- modify the number of cycles for maintenance request
- enter a maintenance request date (optional).
!
The acoustic signal is DISABLED in NIGHT-TIME mode and in case of
BATTERY operation.
15.2 SYSTEM DIAGNOSTICS: ALERTS, ERRORS
The display reads
-
automation STATUSES
14
.
-
ERRORS identified by the
RED LED DL4
STEADY on interrupt auto-
mation operation. If several errors are present at the same time,
each error is signalled after resolving the previous one. See
15
.
-
ALERTS of conditions/phase in progress, identified by the
RED
LED DL4
blinking are described in
16
.
To check active ERROR/ALERT code, press simultan and
-
0.0
RESET/SETUP
DL2
+
-
F
J
13
13
Al
Al
+ alert code
DL4
o
Er
Er
+ error code
DL4
+
-
Summary of Contents for A1400 AIR RD
Page 1: ...A1400 AIR RDT EN16005 2012...
Page 112: ...A1400 AIR RDT 112 53211904 Rev C...
Page 116: ...A1400 AIR RDT 116 53211904 Rev C...
Page 117: ...Translation of the original instructions ENGLISH...