A1400 AIR RDT
54
532119 04 - Rev. C
Tr
ansla
tion of the original instruc
tions
ENGLISH
J13 - MOTOR BLOCK AND MONITORING (OPTIONALS)
J13
Connection of motor block with monitoring (OPTIONALS)
J14 - EMERGENCY BATTERY
!
Installation of the battery is obligatory since it is an essential safety
component.
IMPORTANT: charge the battery before starting up the system.
In this stage, if the battery is flat operation is prevented: only SETUP
may be performed.
When the battery is flat, only setup may be performed; upon comple-
tion the door remains open and error10 is displayed.
The board maintains battery charge, but does not charge batteries
when flat.
To check charge status see LEDs DL5 and DL6 (
52
).
J14
Emergency battery connection
J17 - USB PORT
J17
Connection of the USB memory device
J18 - NOT USED
J21 - CONFIGURABLE INPUTS
V
G
I1
I2
G
I3
I4
V
J21
V
+24V
accessories power supply
I4
Input4
configurable (programming)
I3
Input3
configurable (programming)
G
GND
Accessories power supply negative and Common contacts
I2
Input2
configurable (programming)
I1
Input1
configurable (programming)
G
GND
Accessories power supply negative and Common contacts
V
+24V
accessories power supply
J22 - CONFIGURABLE OUTPUTS
V G 01 02 02
J22
O2
Output2
NC/NO configurable relay output (programming)
O2
Output2
NC/NO configurable relay output (programming)
O1
Output1
configurable (programming)
G
GND
Accessories power supply negative and Common contacts
V
+24V
accessories power supply
J23 J24 J25 - OPTIONAL MODULES
J23
Module connection
G-COM / WI-COM / Net-COM
J24
J25
Summary of Contents for A1400 AIR RD
Page 1: ...A1400 AIR RDT EN16005 2012...
Page 112: ...A1400 AIR RDT 112 53211904 Rev C...
Page 116: ...A1400 AIR RDT 116 53211904 Rev C...
Page 117: ...Translation of the original instructions ENGLISH...