39
ENGLISH
ENGLISH
1
LANGUAGE
(Diagram 2)
Select the language for showing the messages on the display
2
SETUP
(Diagram 3)
2.1 PARTIAL OPENING
Partial opening percentage
Select the opening percentage (referred to total opening)
performed in the “Partial Opening” operational function.
Standard value: 80%
Adjusting range: from 60% to 100%
2.2 PAUSE TIME
Pause time value
Set pause time in the automatic operational function
Standard value: 2 sec.
Adjusting range: from 0 to 30 sec.
2.3 NIGHT PAUSE TIME
Night pause time value
Set pause time in the “night” operational function
Standard value: 7 sec.
Adjusting range: from 0 to 30 sec.
2.4 OBSTACLE DETECTION
Determines the behaviour of the automated system in the
event of repeated obstacle detection during the same
manoeuvre.
Standard
The automated system tries to complete the manoeuvre.
Non Standard
If an obstacle is detected for 3 consecutive times, the
automated system stops. After removing the obstacle, the door
has to be closed manually to restore normal operation
3
LOCK
(Diagram 4)
3.1 KIT LOCK
On
Lock installed.
Night
The lock locks the door only in the “Night” operational function.
One-way+Night
The lock locks the door in the “Night” and “one-way”
operational functions.
Always
The lock locks the door whenever this closes, irrespective of the
set operational function.
Off
Lock not installed.
4
DIAGNOSTICS
(Diagram 5)
4.1 950
The door's hardware model and the software of the 950 MPS
and 950 I/O control boards to which KP-Controller is
connected are shown.
4.2 CYCLES No.
The count (non resettable) of the cycles effected by the
automated system is shown
4.3 ALARM No.
The number and description of the current alarm are shown.
Refer to table 1 for error codes and descriptions.
RESET
Executes reset procedure and, if the cause of signalled
malfunction was removed, it restores normal operation.
5
ADVANCED MENU
PASSWORD
To access the advanced menu, insert the 4-digit password
(default 0000).
1 OPERATION PARAMETERS
(Diagram 6)
1.1 CLOSING SPEED
Sets door speed for closing.
Standard value: level 8
Adjusting range: from 0 to 10
1.2 OPENING SPEED
Sets door speed for opening.
Standard value: level 8
Adjusting range: from 0 to 10
1.3 KEEP SETTINGS
On
The automated system maintains the operating parameters set
with KP-Controller even if this is disconnected.
Off
If the KP-Controller is disconnected, the settings of opening and
closing speeds and pause time must be made using the
trimmers (see Par. 5.2)
2 IN/OUT SETUP
(Diagram 7)
2.1 EMERG
Sets the effect of the emergency command (Emerg input on
950 I/O control board).
Standard setting: Opens/NC
Open
Activating this command opens the door.
Close
Activating this command closes the door.
NO
Normally open input.
NC
Normally closed input.
2.2 OUT OP/CL
Sets operation of
Open
and
Closed
status outputs of 950 I/O
control board
Standard setting: NO
NC
Normally closed input.
NO
Normally open input.
2.3 OUT ALARM
Sets operation of
Alarm
status outputs of 950 I/O control board
Standard setting: NO
NO
Normally open input.
NC
Normally closed input.
3 VARIOUS
(Diagram 8)
3.1 STANDARD SETUP
Used for checking if any non-standard programming operation
was effected.
Standard
If no function was modified with respect to the standard
programming, an asterisk is shown.
If the asterisk is not present, press the “OK” key and all standard
programming functions are reset.
Non Standard
If at least one function was modified with respect to the
standard programming, an asterisk is shown.
3.2 INTERLOCK
The interlock function makes it possible to control two doors
(master and slave) so that opening of one depends on closing
of the other and vice versa.
Off
Interlock function not active.
On
Activates the interlock function.