![background image](http://html1.mh-extra.com/html/faac/844-er-3ph/844-er-3ph_translation-of-the-original-instructions_3125424023.webp)
30
31
844 ER 3PH
21
532366 - Rev.A
(Led
FCC
)
(Led
FCA
)
(Led
FCC
)
(Led
FCA
)
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
!
Installing the limit switches involves moving the leaf manually several
times. Comply with the safety information
§
Manual operation.
1. Fasten each plate to its support, centring the slot with respect to
the threaded pins.
2. Make sure that the flat limit switch cable is connected according
to the opening direction of the gate.
L
The opening direction is established by looking at the 844 ER 3PH from the
release device side (
).
If necessary, move the connection onto the correct connector.
3. Turn the power on.
4. Release the gearmotor and open the leaf manually, leaving a
distance of at least 2 cm from the mechanical stop.
5. Position a plate at the end of the rack and slide it in the opening
direction until the FCA LED on the board switches off. Slide it
along for another 4 cm.
6. Fasten using the screws provided.
7. Close the leaf manually leaving a distance of at least 2 cm from
the mechanical stop.
8. Position the other plate at the end of the rack and slide it in the
closing direction until the FCC LED on the board switches off. Slide
it along for another 4 cm.
9. Fasten using the screws provided.
10. Lock the gearmotor and carry out a complete cycle to check that
the limit switches operate correctly. For a more precise adjust-
ment, regulate the position of the plates via the slots.
7.4 INSTALLING THE END OF TRAVEL PLATES
Installing the end of travel plates.
Closing limit switch
Opening limit switch
Opening limit switch
Opening to the left
Opening to the right
Closing limit switch
Summary of Contents for 844 ER 3PH