background image

ENGLISH

  1)  ATTENTION! To ensure the safety of people, it is important that you read 

all the following instructions. Incorrect installation or  incorrect use of 
the product could cause serious harm to people.

  2)  Carefully read the instructions before beginning to install the product.
  3)  Do not  leave packing materials (plastic, polystyrene, etc.)   within  reach 

of  children as  such materials  are  potential  sources  of  danger.

  4)  Store these instructions for  future reference.
  5)  This product was designed and built strictly for the use indicated in this 

documentation.  Any  other  use,  not  expressly  indicated  here,  could 
compromise the good condition/operation of the product and/or be 
a source of danger.

  6)  FAAC declines all liability caused by improper use or use other than that 

for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the presence 

of  inflammable gas or fumes is a serious danger to safety.

  8)  The mechanical parts must conform to the provisions of Standards EN 

12604 and EN 12605.

 

  For non-EU countries, to obtain an adequate level of safety, the Standards 

mentioned  above  must  be  observed,  in  addition  to  national  legal 
regulations.

  9)  FAAC  is  not  responsible  for  failure  to  observe  Good  Technique  in 

the construction of the closing elements to be motorised, or for any 
deformation that may occur during use.

 10)  The installation must conform to Standards EN 12453 and EN 12445.
 

  For non-EU countries, to obtain an adequate level of safety, the Standards 

mentioned  above  must  be  observed,  in  addition  to  national  legal 
regulations. 

 11)  Before attempting any job on the system, cut out electrical power.
 12)  The mains power  supply of the automated system must be fitted with an 

all-pole  switch with contact opening distance of 3 mm or greater. Use 
of a 6A thermal breaker with all-pole circuit break is recommended.

 13)  Make  sure  that  a  differential  switch  with  threshold  of  0.03  A  is  fitted 

upstream of the system.

 14)  Make sure that the earthing system is perfectly constructed and connect 

metal parts of the closure to it. 

 15)  The automated system is supplied with an intrinsic anti-crushing safety 

device consisting of a torque control. Nevertheless, its tripping threshold 
must  be  checked  as  specified  in  the  Standards  indicated  at  point 
10.

 16)  The safety devices (EN 12978 standard)  protect any danger areas 

against 

mechanical movement Risks

, such as crushing, dragging, and 

shearing.

 17)  Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended 

for every system, as well as a warning sign adequately secured to the 
frame structure, in addition to the devices mentioned at point “16”.

 18)  FAAC declines all liability as concerns safety and efficient operation of 

the automated system, if system components not produced by FAAC 
are used.

 19)  For maintenance, strictly use original parts by FAAC.
 20)  Do  not  in  any  way  modify  the  components  of  the  automated 

system.

 21)  The installer shall supply all information concerning manual operation 

of the system in case of an emergency and shall hand over to the user 
the warnings handbook supplied with the product.

 22)  Do  not  allow  children  or  adults  to  stay  near  the  product  while  it  is 

operating.

 23)  Keep radio controls or other pulse generators away from children, to 

prevent the automated system from being activated involuntarily.

 24)  Transit is permitted only when the automated system is idle.
 25)  The user must not attempt any kind of repair or direct action whatever 

and contact qualified personnel only.

 26)  Check at least every 6 months the efficiency of the system, particularly 

the efficiency of the safety devices (including, where foreseen, the 
operator thrust force) and of the release devices.

 27)  Anything  not  expressly  specified  in  these  instructions  is  not 

permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

CE DECLARATION OF CONFORMITY FOR MACHINES

(DIRECTIVE 006/4/EC)

Manufacturer: 

FAAC S.p.A.

Address:

 

Via Calari, 10  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that: 

Operator mod. 750

 

is built to be integrated into a machine or to be assembled with other machinery to create a machine under 
the provisions of Directive 2006/42/EC

 

conforms to the essential safety requirements of the following EEC directives:

   
 

2006/95/EC    Low Voltage Directive 

 

2004/108/EC  Electromagnetic Compatibility Directive 

 

and also declares that it is prohibited to put into service the machinery until the machine in which it will be 
integrated or of which it will become a component has been identified and declared as conforming to the 
conditions of Directive 2006/42/EEC and subsequent amendments.

 

Bologna, 01-07-2009

 

   

 

 

 

 

The Managing Director

 

   

 

 

 

                A. Marcellan

Summary of Contents for 750 Standard

Page 1: ...750...

Page 2: ...sur les remarques concernant les caract ristiques ou le fonctionnement du produit Vor der Installation des Produkts sind die Anweisungen vollst ndig zu lesen Mit dem Symbol sind wichtige Anmerkungen f...

Page 3: ...Inserto Immagini Pictures Collection Collection de Figure Cojunto de Imagenes Photo Kollektion Fotoverzameling 2 1 5 4 3 200 152 175 400 124 5 6 5 7 7 6 1 2 3...

Page 4: ...4 270 224 470 5 min 60 5 124 152 175 100 270 250 450 470 90 6 a min 60 5 124 152 175 100 270 250 450 470 90 6 b 32 mm 7 8...

Page 5: ...min 1550 max 2840 9 10 245 6 3 5 3 65 1 4 1 5 8 0 5 11 5 12 255 3 6 2 max 65 13 30 14...

Page 6: ...min 100 15 16 C A B D CLOSE OPEN INT EXT 17 18 19 MAX MIN 20...

Page 7: ...1 2 21 22 min 250 23 24 a 24 b 25...

Page 8: ...26 a 26 b 27 28 29...

Page 9: ...on INDEX CE DECLARATION OF CONFORMITY FOR MACHINES 2 WARNINGS FOR THE INSTALLER 2 1 DESCRIPTION AND TECHNICAL SPECIFICATIONS 3 2 INSTALLING THE AUTOMATED SYSTEM 3 2 1 PRELIMINARY CHECKS 3 2 2 INSTALLI...

Page 10: ...pecified in the Standards indicated at point 10 16 The safety devices EN 12978 standard protect any danger areas against mechanical movement Risks such as crushing dragging and shearing 17 Use of at l...

Page 11: ...e 118 200 Max torque Nm 543 750 CBAC SB 272 750 SBS Angular speed sec 7 8 750 CBAC SB 5 2 750 SBS Amount of oil l 0 3 0 5 Protection class IP 67 Weight Kg 8 9 750 AUTOMATED SYSTEM 2 INSTALLING THE AUT...

Page 12: ...etres the centre of the corresponding fittings fig 15 16 The control unit fitting beside the green by pass screw must be connected to the jack fitting that is within the property boundaries fig 17 ref...

Page 13: ...e opens If the first OPEN pulse commands closing invert the phases of the electrical motor on the unit terminal board brown and black wires 3 2 SETTING OPERATION TIME Opening Closing time is determine...

Page 14: ...nd Abbildungen in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Ne...