background image

ENGLISH

Logic  "A"

PULSES

G

A

TE ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING SAFETY DEVICES

CL

OSING SAFETY DEVICES

OP/CL SAFETY DEVICE

EDGE SAFETY DEVICE

CL

OSED

Opens

 the

 leaf

 and

 

closes

 it

  after

 pause

 

time

 (1)

Opens

 leaf

 for

 the

 partial

 

opening

 time

 and

 closes

 

after

 pause

 time

 (1)

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

 

(OPEN

 disabled)

OPEN ON P

A

USE

Reloads

 pause

 time

 (1)

 (3)

Stops

operation

No

 effect

 

(if

 on

 part.opng.

 OPEN

 A

 disabled)

Reloads

 pause

 time

 

(1)

 (3)

  

Reloads

 pause

 time

 (1)

 (OPEN

 disabled)

Reloads

 pause

 time

 (1)

(OPEN

 disabled)

CL

OSING

Re-opens

 the

 leaf

 immediately

 (1)

No

 effect

 

(saves

 OPEN)

See

 paragraph

 5.2.

Locks

 and,

 on

 release,

 

reverses

 to

 open

Reverses

 to

 open

 for

 2"

 (2)

OPENING

No

 effect

 (1)

 (3)

See

 paragraph

 5.2

No

 effect

Locks

 and,

 on

 release,

  

continues

 opening

Reverses

 to

 close

 for

 2"

 (2)

LOCKED

Closes

 the

 leaf

 (3)

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

 

(OPEN

 disabled)

Tab. 3/a

Logic  "AP"

PULSES

G

A

TE ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING SAFETY DEVICES

CL

OSING SAFETY DEVICES

OP/CL SAFETY DEVICE

EDGE SAFETY DEVICE

CL

OSED

Opens

 the

 leaf

 and

 

closes

 it

  after

 pause

 

time

Opens

 leaf

 for

 the

 partial

 

opening

 time

 and

 closes

 

after

 pause

 time

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

 

(OPEN

 disabled)

OPEN ON P

A

USE

Stops

 operation

 (3)

Stops

operation

No

 effect

 

(if

 on

 part.opng.

 OPEN

 A

 disabled)

Reloads

 pause

 time

  (3)

(OPEN

 disabled)

Reloads

 pause

 time

(OPEN

 disabled)

Reloads

 pause

 time

(OPEN

 disabled)

CL

OSING

Re-opens

 the

 leaf

 immediately

No

 effect

 

(saves

 OPEN)

See

 paragraph

 5.2

Locks

 and,

 on

 release,

 

reverses

 to

 open

Reverses

 to

 open

 for

 2"

 (2)

OPENING

Stops

 operation

 (3)

See

 paragraph

 5.2

No

 effect

Locks

 and,

 on

 release,

 con

-

tinues

 opening

Reverses

 to

 close

 for

 2"

 (2)

LOCKED

Closes

 the

 leaf

 (with

  Closing

 Safety

 devices

  

engaged,

 opens

 at

 the

 2nd

 pulse)

 (3)

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

 

(OPEN

 disabled)

Tab. 3/b

Logic  "S"

PULSES

G

A

TE ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING SAFETY DEVICES

CL

OSING SAFETY DEVICES

OP/CL SAFETY DEVICE

EDGE SAFETY DEVICE

CL

OSED

Opens

 the

 leaf

 and

 

closes

 it

  after

 pause

 

time

Opens

 leaf

 for

 the

 partial

 

opening

 time

 and

 closes

 

after

 pause

 time

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

 

(OPEN

 disabled)

OPEN ON P

A

USE

Re-closes

 the

 leaf

 immediately

 (3)

Stops

operation

No

 effect

 

(if

 on

 part.opng.

 OPEN

 A

 disabled)

On

 release,

 closes

 after

 

5"

 (OPEN

 disabled)

 (3)

 

On

 release,

 closes

 after

 5"

(OPEN

 disabled)

Reloads

 pause

 time

(OPEN

 disabled)

 (1)

CL

OSING

Re-opens

 the

 leaf

 immediately

No

 effect

 

(saves

 OPEN)

See

 paragraph

 5.2

 

Locks

 and,

 on

 release,

 

reverses

 to

 open

Reverses

 to

 open

 for

 2"

 (2)

OPENING

Re-closes

 the

 leaf

 immediately

 (3)

See

 paragraph

 5.2

No

 effect

 

(saves

 OPEN)

Locks

 and,

 on

 release,

 con

-

tinues

 opening

Reverses

 to

 close

 for

 2"

 (2)

LOCKED

Closes

 the

 leaf

 (3)

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

 

(OPEN

 disabled)

Tab. 3/c

Logic  "E"

PULSES

G

A

TE ST

A

TUS

OPEN-

A

OPEN-B

STOP

OPENING SAFETY DEVICES

CL

OSING SAFETY DEVICES

OP/CL SAFETY DEVICE

EDGE SAFETY DEVICE

CL

OSED

Opens

 the

 leaf

Opens

 leaf

 for

 the

 partial

 

opening

 time

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

 

(OPEN

 disabled)

OPEN

Re-closes

 the

 leaf

 immediately

 (3)

Stops

operation

No

 effect

 

(if

 on

 part.opng.

 OPEN

 A

 disabled)

No

 effect

(OPEN

 disabled)

 (3)

No

 effect

 

(OPEN

 disabled)

CL

OSING

Re-opens

 the

 leaf

 immediately

No

 effect

 

(saves

 OPEN)

See

 paragraph

 5.2

 

Locks

 and,

 on

 release,

 

reverses

 to

 open

Reverses

 to

 open

 for

 2"

 (2)

OPENING

Stops

 operation

 (3)

See

 paragraph

 5.2

No

 effect

Locks

 and,

 on

 release,

  

continues

 opening

Reverses

 to

 close

 for

 2"

 (2)

LOCKED

Closes

  the

 leaf

 (with

  Closing

 Safety

 devices

  

engaged,

 opens

 at

 the

 2nd

 pulse)

 (3)

No

 effect

 

(OPEN

 disabled)

No

 effect

No

 effect

 

(OPEN

 disabled)

Tab. 3/d

Summary of Contents for 578D

Page 1: ...4 4 J1 TERMINAL BOARD ACCESSORIES FIG 2 6 4 5 CONNECTOR J2 RAPID CONNECTION TO MINIDEC DECODER AND RP 7 4 6 CONNECTION OF OPERATOR 844 7 4 7 CONNECTION OF OPERATOR 541 7 4 8 CONNECTION OF OPERATORS W...

Page 2: ...an adequate level of safety the Standards mentioned above must be observed in addition to national legal regulations 11 Before attempting any job on the system cut out electrical power 12 The mains po...

Page 3: ...ON Power supply V 6 10 230 Absorbed power W 10 Motor max load W 1000 Accessories max load A 0 5 Operating ambient temperature 20 C 55 C Protection fuses 2 see fig 1 Function logics Automatic Stepped a...

Page 4: ...sing movements They cause immediate reversal of motion and stopping after two seconds Encoder itistrippedifthereisanobstacleduringgateopening and closing movements It causes immediate reversal of moti...

Page 5: ...photocells and a pair of opening closing photocells Connection of a pair of closing photocells a pair of opening photocells and a pair of opening closing photocells Connection of a pair of opening pho...

Page 6: ...contact stops gate movement To install several STOP devices connect the N C contacts in series fig 4 NB IfSTOPdevicesarenotconnected jumperconnect the STOP and terminals SAFE EDGEsafetydevicecontact...

Page 7: ...h respectto theconnectionbetweentheSTOPinputof578D and the SAFETY of the 541 INTERFACE Refer to paragraph 6 3 for instructions on putting into operation To make connections between the 578D equipment...

Page 8: ...FC1 FC2 2 1 FC1 FC2 ENGLISH Fig 21 Fig 19 Fig 20...

Page 9: ...Disabled FINAL BRAKING When the gate engages the opening or closing limit switch a braking stroke can be selected to ensure the leaf is stopped immediately If decelerations are selected braking starts...

Page 10: ...or they reverse it immediately Y Reverse immediately to closing no Restart movement on release ENCODER Iftheencoderisused youmayselectitspresence If the encoder is present and enabled decelerations a...

Page 11: ...nd activated Command inactive OP B Command activated Command inactive FC1 Limit switch free Limit switch engaged FC2 Limit switch free Limit switch engaged FW OP Safety devices disengaged Safety devic...

Page 12: ...crushing system ANTI CRUSHING SAFETY DEVICE DURING CLOSING although it has an Encoder sensor the 541 operator cannot intrinsically guarantee this safety device because it is not fitted directly on th...

Page 13: ...f with Closing Safety devices engaged opens at the 2nd pulse 3 No effect OPEN disabled No effect No effect OPEN disabled Tab 3 b Logic S PULSES GATE STATUS OPEN A OPEN B STOP OPENING SAFETY DEVICES CL...

Page 14: ...ETY DEVICES OP CL SAFETY DEVICE EDGE SAFETY DEVICE CLOSED Opens the leaf No effect No effect OPEN A disabled No effect No effect OPEN A disabled OPEN No effect Closes the leaf No effect OPEN B disable...

Reviews: