9. Start-up

  LED Indicators: 

The board has a two-digit display. When not in 

“PROGRAMMING” mode, this display is used to indicate 

the status of inputs. The figure below shows how the LED 

segments are mapped to the corresponding the inputs.

The table below shows the status of the LEDs in relation to 

the status of the inputs.
Note the following:

 

LED ON

  = closed contact

 

 

 

LED OFF

 = open contact

Operation of the Status Signaling LEDs

The status of the LEDs while the gate is closed at rest are shown 

in bold. 

    Rotation direction and force check:

1.  Program the functions of the 455 D control board ac-

cording to need, as previously shown.

2.  Turn power off to the control board.
3.  Release the operators and manually move the gate 

to the mid-point of the opening angle.

4.  Re-lock the operators.
5.  Restore power.
6.  Send an opening command on the OPEN A input and 

verify that the gate leaves start moving towards the  

open position

Note: If the first OPEN A pulse starts a closing movement, 

turn power off and reverse the phases of the electric 

motor (red and black wires) on the 455 D control board.

7.  Check force setting of the motors, modify if necessary.

Note: For hydraulic operators, like the 400, force should be 

programmed to maximum level (50)

8.  Stop leaf movement with a pulse on the STOP input or 

turning off power.

9.  Release the operators, close the leaves and re-lock 

the operators.

Opening/closing time is established by a time learning pro-

cedure which can be accomplished in “simple” or “com-

plete” modes. The simple mode doesn’t allow a slow down 

phase in the operator, while the complete mode does.

The slow down can be useful to reduce the mechanical 

stress on the gate, but it can create problems in high wind 
conditions. 

LEDs

ON

OFF

OP_A

Command activated

Command inactive

OP_B

Command activated

Command inactive

STOP

Command inactive

Command activated

FSWCL

Safety devices clear

Safety devices triggered

FSWOP

Safety devices clear

Safety devices triggered

FCA1 (if used)

Limit switch free

Limit switch triggered

FCC1 (if used)

Limit switch free

Limit switch triggered

FCC2 (if used)

Limit switch free

Limit switch triggered

FCA2 (if used)

Limit switch free

Limit switch triggered

This is the normal status of the display with all the safety 

inputs clear and no activation signal present

Summary of Contents for 455D220A.5

Page 1: ...Board FAAC International Inc Headquarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue...

Page 2: ...be excluded Thrust Force Adjustable on 50 levels for each motor Terminal Board Inputs Open Open Free Leaf Stop Limit switch Opening Safety Devices Closing Safety Devices Power Supply Earth Terminal B...

Page 3: ...connected to this input See the next paragraph on how to connect a monitored device If this input is active when the gate is open it will prevent the leaf closing movement OP FSW Opening safety device...

Page 4: ...e connected for the system to work 1 2 5 4 3 1 2 RX CL TX CL 9 10 11 12 13 14 15 16 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW 20 21 W L LOCK 1 2 5 4 3 1 2 RX OP TX OP 1 2 5 4 3 1 2 RX CL TX CL 9 10 1...

Page 5: ...ct Typically these photocells work in combination with other monitored photocell pro tecting closing or opening entrapment zones In that case they can t be monitored so they can only protect against p...

Page 6: ...ill display the param eter s current value Value can be modified with keys and Press and hold F again the unit will display the name of the next function parameter When you reach the last function pre...

Page 7: ...d OFF when gate is closed the output is ON when the gate is open or in pause OFF in all other conditions the output is ON when the gate is closed OFF in all other conditions All other values correspon...

Page 8: ...nd black wires on the 455 D control board 7 Check force setting of the motors modify if necessary Note For hydraulic operators like the 400 force should be programmed to maximum level 50 8 Stop leaf m...

Page 9: ...2 stops at opening and immediately begins its closing movement 5 Slow down at closing of leaf 2 6 Leaf 2 stops at closing and leaf 1 begins its closing movement 7 Slow down at closing of leaf 1 8 Leaf...

Page 10: ...i t n o c e s a e l e r n o d n a s k c o L g n i n e p o D E K C O L 3 f a e l e h t s e s o l C t c e f f e o N d e l b a s i d N E P O t c e f f e o N t c e f f e o N d e l b a s i d N E P O E c i...

Page 11: ...diately stops operation NB Effects on other active pulse inputs in brackets P A c i g o L S E S L U P S U T A T S E T A G A N E P O B N E P O P O T S S E C I V E D Y T E F A S G N I N E P O S E C I V...

Page 12: ...OR 1 MOTOR 2 CL COM OP 1 2 3 4 5 6 7 8 20 21 FCA1 FCA2 FCC2 FCC1 F J2 J6 J4 J5 J3 N L MAIN OP CL 24 V FSW B STOP A TX FSW 9 10 11 12 13 14 15 16 17 18 19 J1 PHOTO OP OPEN DEVICES PHOTO CL 24VDC RX PHO...

Page 13: ...prewired enclosure comes with dedicated terminal blocks for the connection of safety photocells that can be monitored by the control board for presence and correct operation One closing and one openi...

Page 14: ...ections If using non FAAC relay make sure the minimum switch volt age is less than 12Vac SHADOW INPUT Line Voltage MOTOR ON 24 VDC SHADOW LOOP 120V or 230 AC SHADOW KIT OPTION 8 7 10 1 2 5 Shadow Loop...

Page 15: ...sume for them any other liability in connection with the sale or use of the products of beyond that extended herein The warranty hereinabove set forth shall not be deemed to cover maintenance parts in...

Page 16: ...2021 FAAC International Inc All Rights Reserved Published in Jan 2021 455D 532218 Rev B US...

Reviews: