![FAAC 455D220A.5 Manual Download Page 14](http://html1.mh-extra.com/html/faac/455d220a-5/455d220a-5_manual_3102569014.webp)
14
LOCK
24 VDC
- + +
+ -
24 VDC
MAG LOCK
24V AC
MAGLOCK KIT OPTION
Maglock connection
The prewired enclosure comes with dedicated terminal
blocks for the connection of a relay to drive a Maglock.
The Maglock kit can be ordered separately as an accessory.
Refer to this schematic for the connections.
If using non-FAAC relay make sure the minimum switch volt-
age is less than 12Vac
SHADOW
INPUT
Line Voltage
MOTOR
ON
24 VDC
- +
SHADOW
LOOP
120V or 230 AC
SHADOW KIT OPTION
8
7
10
1
2
5
Shadow Loop kit option
The prewired enclosure comes with dedicated terminal
blocks for the connection of a relay and a loop detec-
tor socket to implement the shadow loop functionality. The
Shadow loop kit can be ordered separately as an accessory.
Refer to this schematic for the connections.