The installer is responsible for grounding the operator 

system, for providing the main power breaker switch, 

and for making sure that the entire gate system meets 

all applicable electrical codes. 

J4

J1

J3

F1

F2

PE N L

MAIN

1

2

4

5

6 7 8

COM OP

M1

COM OP

M2 CL

LAMP

9 10 11 12 13 14 15 16 17 18 19

OPEN

A

B STP CL OP

FSW

-

-

-

+24V

+

+

-TX

FSW

20 21

W.L.

LOCK

J5

J2

F

22

23

24 25

FC

A1

FC

C1

FC

A2

FC

C2

+

STOP

OP_A

OP_B

FSWCL

FSWOP

FCC1

FCC2

FCA1

FCA2

J6

F

F1

F2

J1

J2

J3

J4

J5

J6

DL

+

Input Voltage

115 V~ ± 10% or 

230 V~ +6%  -10%   

50/60 Hz

Input Power

10 W

Motor Max. Load

800 W

Accessories Max. Load

0,5 A

Electric Lock Max. Load

15 VA

Ambient Operating Temperature Range

-4°F to +131°F

Protection Fuses

5A  (230V version)
10A (115V Version)
800 mA (accessory)

DL

  STATUS AND PROGRAMMING DISPLAY

J1

   LOW VOLTAGE TERMINAL BLOCK

J2

   CONNECTOR FOR RADIO RECEIVER

J

3   

AC POWER SUPPLY TERMINAL BLOCK

J4

   MOTORS AND WARNING LAMP TERMINAL BLOCK

J5

   INDICATOR-LIGHT AND ELECTRIC LOCK TERMINAL BLOCK

J6

   LIMIT-SWITCH TERMINAL BLOCK

F1

   MOTORS AND TRANSFORMER PRIMARY WINDING   

 

       FUSE (F 5A - 230V) (F 10A - 115V)

F2

   LOW VOLTAGE AND ACCESSORIES FUSE (T 800mA)

F     

“F”  PROGRAMMING PUSH-BUTTON

 –     

“–”  PROGRAMMING PUSH-BUTTON

+     

“+”  PROGRAMMING PUSH-BUTTON

3. Features

Function Logics

Semi-automatic / Automatic / Safety Devices / “Stepped” Semi-

automatic / “Stepped” Automatic / “Stepped” Safety Devices  / 

Semi-automatic B / Dead-man C

Opening/Closing Time:

Programmable (from 0 to 120 s)

Pause Time:

Programmable (from 0 to 4 min.)

Closing Leaf Delay:

Programmable (from 0 to 4 min.)

Opening Leaf Delay:

2 s (can be excluded)

Thrust Force

:

Adjustable on 50 levels for each motor

Terminal Board Inputs

Open / Open Free Leaf / Stop / Limit-switch / Opening Safety Devices 

/ Closing Safety Devices / Power Earth.

Terminal Board Outputs

:

Flashing Lamp / Motors / 24 VDC Accessories Power Supply / 24 VDC 

Indicator-Light / Fail Safe / 12 VAC Electric Lock Power Supply

Programmable Functions

Logic / Pause Time / Thrust Force / Torque at Initial Thrust / Opening and 

Closing Leaf Delay / Reversing Stroke / Over-Pushing Stroke / Indicator-

Light /  Pre-Flashing / Electric Lock / Fail Safe / Safety Devices Logic 

/ Assistance Request / Detection Time of Obstacle or Contact Point

Learning Function

:

Simple or complete work time learning, with or without Limit-switches

Terminal Block J3 - Power Supply

PE:

 

Earth Connection / Ground

N: 

AC

 

V~ power supply (Neutral)

L: 

AC V~ power supply (Line)

Connector J2 - Rapid Connection to RP Receivers

455 D

RP 418 DS

RP 433 RC

1. General Description

The 455 D control board is used to operate the FAAC High 

Voltage swing gate operators. It has several operating logics 

built in, programmable with the help of a display and push-

buttons. The board allows connection of various accessories 

including monitored photocell for compliance with the 

UL325 standard Ed: 7. 

The 455D control board allows the connection of 1 close 
and up to 2 open entrapment protection devices. 

The board should be installed in an enclosure that is con-

veniently located as close as possible to the gate operator. 

All electrical connections from the control board to the 
operator must be made in a weatherproof junction box.

The 5 pin J2 connector allows to plug in the FAAC RP radio 

receivers

455D CONTROL BOARD

2. Technical Specifications

4. Layout and Components

Summary of Contents for 402

Page 1: ...Operator FAAC International Inc Headquarter East Coast Operations 3160 Murrell Road Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia A...

Page 2: ...Checks 7 2 2 Installation Dimensions 7 2 3 General Rules 7 2 4 Installing the Operator 7 2 5 By Pass Valves adjustment 10 3 MANUAL OPERATION 10 4 MAINTENANCE 10 455D CONTROL BOARD 1 General Descripti...

Page 3: ...an usage Locate the gate such that persons will not come in contact with the vehi cular gate during the entire path of travel of the vehicular gate c The gate must be installed in a location so that e...

Page 4: ...ipment may reach high thermal temperatures during normal operation therefore use caution when touching the external housing of the gate operator Use the manual release mechanism according to the proce...

Page 5: ...factory or loa ding dock area or other locations not accessible by or intended to service the general public CLASS IV RESTRICTED ACCESS VEHICULAR GATE OPERATOR A vehicular gate operator or system int...

Page 6: ...button Radio receiver Warning light Electric lock if necessary Always separate the connection cables of the low voltage accessories from the high voltage power cables Use separate conduits to avoid in...

Page 7: ...steps 1 Attach the rear mounting bracket 2 Attach the operator to the rear mounting bracket 3 Attach the front mounting bracket to the operator 4 Attach the operator to the gate 5 Adjust the hydraulic...

Page 8: ...elease mechanism on the underside of the operator and turn the key counterclockwise one turn For inward swing pull the piston completely out and push it back inward approximately 1 4 6mm For outward s...

Page 9: ...on should not bottom out in either direction Be sure that the gate reaches the positive stop before the piston bottoms out Attach the connector with the cable and secure it with the supplied screws Fi...

Page 10: ...electric motor as shown in Fig 16 Remove the screwdriver and check oil level as shown in Fig 16 USE ONLY FAAC HP FLUID OIL Periodically check the correct adjustment of the anti crushing safety device...

Page 11: ...11 This page is intentionally left blank...

Page 12: ...n be excluded Thrust Force Adjustable on 50 levels for each motor Terminal Board Inputs Open Open Free Leaf Stop Limit switch Opening Safety Devices Closing Safety Devices Power Supply Earth Terminal...

Page 13: ...connected to this input See the next paragraph on how to connect a monitored device If this input is active when the gate is open it will prevent the leaf closing movement OP FSW Opening safety devic...

Page 14: ...e connected for the system to work 1 2 5 4 3 1 2 RX CL TX CL 9 10 11 12 13 14 15 16 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW 20 21 W L LOCK 1 2 5 4 3 1 2 RX OP TX OP 1 2 5 4 3 1 2 RX CL TX CL 9 10 1...

Page 15: ...act Typically these photocells work in combination with other monitored photocell pro tecting closing or opening entrapment zones In that case they can t be monitored so they can only protect against...

Page 16: ...ill display the param eter s current value Value can be modified with keys and Press and hold F again the unit will display the name of the next function parameter When you reach the last function pre...

Page 17: ...nd OFF when gate is closed the output is ON when the gate is open or in pause OFF in all other conditions the output is ON when the gate is closed OFF in all other conditions All other values correspo...

Page 18: ...and black wires on the 455 D control board 7 Check force setting of the motors modify if necessary Note For hydraulic operators like the 400 force should be programmed to maximum level 50 8 Stop leaf...

Page 19: ...2 stops at opening and immediately begins its closing movement 5 Slow down at closing of leaf 2 6 Leaf 2 stops at closing and leaf 1 begins its closing movement 7 Slow down at closing of leaf 1 8 Leaf...

Page 20: ...i t n o c e s a e l e r n o d n a s k c o L g n i n e p o D E K C O L 3 f a e l e h t s e s o l C t c e f f e o N d e l b a s i d N E P O t c e f f e o N t c e f f e o N d e l b a s i d N E P O E c i...

Page 21: ...diately stops operation NB Effects on other active pulse inputs in brackets P A c i g o L S E S L U P S U T A T S E T A G A N E P O B N E P O P O T S S E C I V E D Y T E F A S G N I N E P O S E C I V...

Page 22: ...OR 1 MOTOR 2 CL COM OP 1 2 3 4 5 6 7 8 20 21 FCA1 FCA2 FCC2 FCC1 F J2 J6 J4 J5 J3 N L MAIN OP CL 24 V FSW B STOP A TX FSW 9 10 11 12 13 14 15 16 17 18 19 J1 PHOTO OP OPEN DEVICES PHOTO CL 24VDC RX PHO...

Page 23: ...prewired enclosure comes with dedicated terminal blocks for the connection of safety photocells that can be monitored by the control board for presence and correct operation One closing and one openi...

Page 24: ...ections If using non FAAC relay make sure the minimum switch volt age is less than 12Vac SHADOW INPUT Line Voltage MOTOR ON 24 VDC SHADOW LOOP 120V or 230 AC SHADOW KIT OPTION 8 7 10 1 2 5 Shadow Loop...

Page 25: ...Head Screw 5x20mm Part Part Number Description 25 7110015 Oil Plug 26 2274 Vent Screw 27 7094065 Copper Gasket 28 3204425 Cast Iron Pump 1 Lt 29 706122 Pump Pin 30 7203275 By Pass Protection Cover 31...

Page 26: ...111 7090635 O Ring 5x1 5 Retract Tube 112 7361315 Retract Tube Alum 113 7230225 Tie Rod Cylinder 114 63000655 Seal Front Flange Internal 115 703204 Star Washer Part Part Number Description 116 499416...

Page 27: ...s been subject to misuse negligence or accident or has not been oper ated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe tha...

Page 28: ...2018 FAAC International Inc All Rights Reserved Published in July 2018 402 732143 Rev B US...

Reviews: