The closing leaf-delay time is adjustable from 1.5 to 10 

seconds.  

 

N

OTE

If the opening/closing time is set at less than 

the leaf delay time, the delayed leaf closes at the end 

of the closing time. 

 

S

ETTING

 

THE

 

DIP

 

SWITCHES

 

 

Set the dip switches as follows: 

 

 

 

 

 

 

 

O

BSTACLE

 R

ECOGNITION

 

 

 In the event that two obstacles are sensed in succession, 

the motor(s) will stop. At this point the control panel will 

require an activation signal which will cause the motor(s) 

to run open and then close at slow speed to “reprogram” 

the location of the open and closed limit switches. 

P age  17 

July ,   2 00 6  

3 9 0  24 v  O pe ra t or  A nd   
4 2 5  D  C ontrol   Pa ne l  I nsta ll a ti on Ma nua l   

T

HE

 42
5 D C

ONTR

OL

 P

ANE

L

 I

NST

A

LLATION

 I

NSTR

U

C

TI

O

NS

 

Figure 3.  

Wiring detail (a) inside the junction box and (b) from the 

junction box or  operator to the high-voltage terminal strip 

on the 425 D control panel 

U.L. Listed Control Panel Enclosure 

Cord grip or conduit 

from  

U.L. Listed gate 

operator(s) 

(b)

 

Op.1

 

Op.2

 

          

OP  CL          OP  CL 

       

 

CN2

 

CN2 

terminal strip 

425 D Control Panel 

 

Ground

 

CN3/CN4

 

To the U. L. Listed gate operator

 

To the U.L. Listed 

control panel

 

U.L. Listed 

cord grip 

Junction box 

Legend

 

Blue

 

Brown

 

Black

 

Blue/Brown 
(motors)

 

(a)

 

Conduit to U.L. Listed con-

trol panel enclosure ac-

cording to N.E.C. 

during closing reopens the gate.  A 

maintained open command  will hold the gate 

open. 

 

• 

EP (semi-automatic, step by step):

 

This 

mode requires a command to open and a 

command to close. A second command 

during opening or closing causes the gate to 

stop. A third command then reverses the 

previous motion of the gate. 

 

The two programming push buttons allow the 

programming of the force, logic settings, etc 

 

WARNING

Turn the main power off before you 

make any electrical connections. 

 

P

AUSE

  T

IME

:  

The pause time between opening and 

closing is set during the motor run time programming 

section. 

 

L

EAF

  D

ELAY

You may choose to delay one leaf on 

closing for overlapping gate leaves. Be sure the 

operator on the leaf for delayed closing is connected 

to Motor 1.  

 

The opening leaf-delay time of 1.5 seconds cannot be 

adjusted.  

Summary of Contents for 390 24 V

Page 1: ...6 Install the Operator 7 Mounting Dimensions 7 Mounting the Base Plate 7 390 Limit Switch Instructions 10 Exploded View 390 24V Operator 12 390 24V Operator Parts List 13 The 425 D Control Panel Gene...

Page 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Page 3: ...ower before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation theref...

Page 4: ...ximum leaf length ft m 14 3 Maximum leaf swing deg 120 Figure 1 390 Operator Dimensions 2 3 8 4 13 1 16 9 7 8 1 4 3 8 4 5 1 6 15 3 4 1 1 3 4 5 1 2 2 3 8 16 1 8 5 1 8 5 1 8 Parameter Measure Motor RPM...

Page 5: ...te any damage because the carrier must witness the damage before you can file a claim As you unpack the box insure that all the parts listed below are included See Figure 2 Control panel enclosure wit...

Page 6: ...et during Basic Programming of the 425 D Control Panel see page 19 for Basic Programming Reversing devices such as inductive loops and photocells should be installed to provide non contact reversing o...

Page 7: ...hose indicated in the technical specifications Make sure that the leaves move properly without any binding during their entire travel Check if hinges are in good condition Make sure the positive stops...

Page 8: ...el Installation Manual A B C max a 2 4 4 5 28 90 4 6 4 5 28 90 6 8 4 5 28 90 8 10 4 5 27 90 10 12 4 5 27 90 12 14 4 5 26 90 2 4 7 8 25 120 4 6 9 10 23 120 6 8 11 12 21 120 8 10 12 13 20 120 Figure 5 D...

Page 9: ...ual Figure 6 Typical overhead outward swing mounting dimensions for garage carriage door applications A B C max a 2 4 4 5 28 90 4 6 4 5 28 90 6 8 4 5 28 90 8 10 4 5 27 90 10 12 4 5 27 90 12 14 4 5 26...

Page 10: ...mit Switches Open and Closed Stops Figure 7 Figure 8 Figure 9 Figure 7 shows how to attach the operator to the base plate Figure 8 shows how to assemble the articulated arm and front bracket Figure 9...

Page 11: ...gate 1 Operator Wire Gauges for Given Voltage 2 Control Panel Enclosure 110 VAC primary 24 VAC 100 VA secondary 3 Photocell A 2 18 AWG A 2 18 AWG 4 Power Switch B 4 14 AWG B 4 14 AWG 5 FAAC 5 Wire Cab...

Page 12: ...Page 12 July 2006 390 24v Operator And 425 D Control Panel Installation Manual The 390 24v Operator...

Page 13: ...13 N A Manual Release Outer 1 14 722471 Mounting Frame 1 15 N A Bushing Brass Bottom 1 16 N A Fender Washer 1 17 N A Motor 24VDC 1 20 N A Motor Housing 24VDC 1 21 N A Snap Ring 1 22 N A Seal Lower 1 2...

Page 14: ...operator to the control panel Checking the direction of the motor s rotation Connecting other devices to the control panel Set operating modes CONNECT THE MAIN POWER SUPPLY WARNING Turn the main power...

Page 15: ...be used to power 24 VDC accessories NOTE The 425 D control panel allows a maximum accessory load of 630mA REVERSING DEVICES Reversing devices include photocells inductive loops and so forth All of the...

Page 16: ...OP and FSWCL should be illuminated except when the reversing devices for opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have i...

Page 17: ...ted gate operator s b Op 1 Op 2 OP CL OP CL CN2 CN2 terminal strip 425 D Control Panel Ground CN3 CN4 To the U L Listed gate operator To the U L Listed control panel U L Listed cord grip Junction box...

Page 18: ...Photocells 3 4 Wire Radio Receivers DC Radios Only N C N O COM 24 vdc Relay 1 2 1 2 3 4 5 Additional Reversing Devices TX RX NO C If 4 Wire Receiver Activation Devices Free Exit Loop Phone Keypad C N...

Page 19: ...ore you make any electrical connections or set any switches inside the control panel box To program the automated system the Programming Mode must be accessed The 425D has two push buttons labeled P1...

Page 20: ...he open direction touch the two RESET JMP1 pins see figure 2 with a small screwdriver or piece of wire This will cause the gate to stop 6 Turn the power off to the control panel and reverse the motor...

Page 21: ...oth directions before the automatic operator is installed An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the prope...

Page 22: ...he reversing devices are working properly FSWOP and FSWCL should be illuminated except when a reversing device is triggered If either does not illuminate then one of your reversing devices is preventi...

Page 23: ...Page 23 July 2006 390 24v Operator And 425 D Control Panel Installation Manual NOTES...

Page 24: ...dance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s...

Reviews: