background image

Pag e 6 

Jul y ,   2 00 6  

3 9 0  24 v   O pe ra t or   And  

4 2 5  D  C ontrol   Pa ne l  I nsta ll a ti on  Ma nua l  

T

HE

 390 24

V

 O

PERATOR

 

G

ENERAL

 C

HARACTERISTICS

 

 

The FAAC 390 24v Operator is an automatic gate 

operator for a residential swinging gate leaf  that is 

ideal for large columns.   

 

The self-contained 390 24v Operator consists of a 

irreversible electromechanical motor and articulated 

arm. 

 

The locking the 390 24v Operator provides in the fully 

opened and fully closed positions is a service device 

rather than a security device. Additional, external locks 

are recommended under the following conditions: 

 

∗ 

It is a solid-faced gate. 

∗ 

The length of the gate leaf is 6 ft (2 m) or longer. 

∗ 

The installation requires tight security. 

∗ 

The site is subject to vandalism. 

∗ 

The site is subject to strong or very gusty wind 

 

In two-operator gate installations, both (master/slave) 

operators are wired to one control panel. 

 

The electronic control panel is a microprocessor-based 

controller that accepts a wide range of product 

accessories and reversing devices, thus allowing for 

flexible gate system design. 

 

Also for the protection and proper operation of the 390 

24v Operator, each operator has available optional limit 

switches.   

 

Built-in security and anti-crushing measures of the 390 

24v Operator include built in reverse on contact and a 

torque adjustment that controls the force transmitted to 

the gate leaf through the 390 24v Operator. 

 

The Manual Release mechanism is a key-operated device 

that disengages (or engages) the gears in 390 24v 

Operator. When the drive is disengaged, you can open 

and close the gate leaf by hand. Such manual operation 

of the gate is necessary during installation and useful 

during prolonged power failures. 

 

The torque of the 390 24v Operator is set during Basic 

Programming of the 425 D Control Panel.  (see page 19 

for Basic Programming). 

 

Reversing devices (such as inductive loops and 

photocells) should be installed to provide non-contact 

reversing operation. 

 

WARNING: 

To insure that the installation meets the UL 

325 Standards. A set of photo beam (Part Number 

785163) must be installed anywhere that an entrapment 

with the gate leaf(s) could happen. 

 

The 425 D also has a built in battery back-up system 

that can be used with the addition of 2 12V 7ah 

batteries. The batteries must be wired in series to 

provide 24VDC to the control panel during power 

outages. 

 

During prolonged power outages the manual release 

may be used if needed. 

Make sure that the gate structure is solidly built. Add 

reinforcing crosspieces if necessary to the gate leaves. 

Make sure that the gate moves smoothly on its hinges 

without excessive friction by swinging it opened and 

closed by hand. If necessary, lubricate all the gate's 

moving parts. 

 

Positive stops are needed with the 390 24v Operator 

unless you have purchased the optional Limit Switch Kit 

(FAAC Part Number 390682)

 

 

M

ANUAL

 R

ELEASE

 M

ECHANISM

 

 

To manual release the 390 24v Operator perform the 

following steps as shown in figure 3. 

 

I

NSTALLATION

 I

NSTRUCTIONS

 

Installing the 390 24v Operator involves preparing the 

gate, installing the operator(s), installing the control 

panel, programming control panel, and connecting 

other operational controls. 

 

Note: 

The following installation instructions assume 

you are fully capable of installing an electromechanical 

operator on a gate. This manual does not instruct you 

in designing a gate, installing a gate (whether on 

masonry, wood, or metal posts), or basic electrical 

wiring. The installation tasks discussed in this manual 

are tasks particular to the 390 24v Operator. 

 

P

REPARE

 

THE

 G

ATE

 

 

Before you install the 390 24v Operator, you need to 

prepare the gate itself for the operator. Be sure to do 

the following: 

Summary of Contents for 390 24 V

Page 1: ...6 Install the Operator 7 Mounting Dimensions 7 Mounting the Base Plate 7 390 Limit Switch Instructions 10 Exploded View 390 24V Operator 12 390 24V Operator Parts List 13 The 425 D Control Panel Gene...

Page 2: ...affected by the size of the gate how often it is used and how fast the gate operates 2 The operator you choose to install on your gate must be designed for the type and size of your gate and for the...

Page 3: ...ower before making any attempt to repair it 4 Do not attempt to impede the movement of the gate You may injure yourself as a result 5 This equipment may reach high temperatures during operation theref...

Page 4: ...ximum leaf length ft m 14 3 Maximum leaf swing deg 120 Figure 1 390 Operator Dimensions 2 3 8 4 13 1 16 9 7 8 1 4 3 8 4 5 1 6 15 3 4 1 1 3 4 5 1 2 2 3 8 16 1 8 5 1 8 5 1 8 Parameter Measure Motor RPM...

Page 5: ...te any damage because the carrier must witness the damage before you can file a claim As you unpack the box insure that all the parts listed below are included See Figure 2 Control panel enclosure wit...

Page 6: ...et during Basic Programming of the 425 D Control Panel see page 19 for Basic Programming Reversing devices such as inductive loops and photocells should be installed to provide non contact reversing o...

Page 7: ...hose indicated in the technical specifications Make sure that the leaves move properly without any binding during their entire travel Check if hinges are in good condition Make sure the positive stops...

Page 8: ...el Installation Manual A B C max a 2 4 4 5 28 90 4 6 4 5 28 90 6 8 4 5 28 90 8 10 4 5 27 90 10 12 4 5 27 90 12 14 4 5 26 90 2 4 7 8 25 120 4 6 9 10 23 120 6 8 11 12 21 120 8 10 12 13 20 120 Figure 5 D...

Page 9: ...ual Figure 6 Typical overhead outward swing mounting dimensions for garage carriage door applications A B C max a 2 4 4 5 28 90 4 6 4 5 28 90 6 8 4 5 28 90 8 10 4 5 27 90 10 12 4 5 27 90 12 14 4 5 26...

Page 10: ...mit Switches Open and Closed Stops Figure 7 Figure 8 Figure 9 Figure 7 shows how to attach the operator to the base plate Figure 8 shows how to assemble the articulated arm and front bracket Figure 9...

Page 11: ...gate 1 Operator Wire Gauges for Given Voltage 2 Control Panel Enclosure 110 VAC primary 24 VAC 100 VA secondary 3 Photocell A 2 18 AWG A 2 18 AWG 4 Power Switch B 4 14 AWG B 4 14 AWG 5 FAAC 5 Wire Cab...

Page 12: ...Page 12 July 2006 390 24v Operator And 425 D Control Panel Installation Manual The 390 24v Operator...

Page 13: ...13 N A Manual Release Outer 1 14 722471 Mounting Frame 1 15 N A Bushing Brass Bottom 1 16 N A Fender Washer 1 17 N A Motor 24VDC 1 20 N A Motor Housing 24VDC 1 21 N A Snap Ring 1 22 N A Seal Lower 1 2...

Page 14: ...operator to the control panel Checking the direction of the motor s rotation Connecting other devices to the control panel Set operating modes CONNECT THE MAIN POWER SUPPLY WARNING Turn the main power...

Page 15: ...be used to power 24 VDC accessories NOTE The 425 D control panel allows a maximum accessory load of 630mA REVERSING DEVICES Reversing devices include photocells inductive loops and so forth All of the...

Page 16: ...OP and FSWCL should be illuminated except when the reversing devices for opening and closing respectively are triggered Use the LEDs and the next table to determine if the accessory devices you have i...

Page 17: ...ted gate operator s b Op 1 Op 2 OP CL OP CL CN2 CN2 terminal strip 425 D Control Panel Ground CN3 CN4 To the U L Listed gate operator To the U L Listed control panel U L Listed cord grip Junction box...

Page 18: ...Photocells 3 4 Wire Radio Receivers DC Radios Only N C N O COM 24 vdc Relay 1 2 1 2 3 4 5 Additional Reversing Devices TX RX NO C If 4 Wire Receiver Activation Devices Free Exit Loop Phone Keypad C N...

Page 19: ...ore you make any electrical connections or set any switches inside the control panel box To program the automated system the Programming Mode must be accessed The 425D has two push buttons labeled P1...

Page 20: ...he open direction touch the two RESET JMP1 pins see figure 2 with a small screwdriver or piece of wire This will cause the gate to stop 6 Turn the power off to the control panel and reverse the motor...

Page 21: ...oth directions before the automatic operator is installed An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the prope...

Page 22: ...he reversing devices are working properly FSWOP and FSWCL should be illuminated except when a reversing device is triggered If either does not illuminate then one of your reversing devices is preventi...

Page 23: ...Page 23 July 2006 390 24v Operator And 425 D Control Panel Installation Manual NOTES...

Page 24: ...dance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding those set forth in the specifications for such product s...

Reviews: