7
Specification
Parameters
Descriptions
Model
CS-T4C
Name
Smoke Sensor
Product Implementation
Standard
EN 14604:2005;
EN 14604:2005/AC:2008
Working Principle
Photoelectric Type
Communication Mode
ZigBee
Alarm Volume
≥ 85dB@3m (A-weighted)
Local Alarm Mode
Sound-light Alarm
Working Voltage
DC 3V, Lithium Battery CR14250
Standby Current
≤ 15μA
Average Alarm Current
≤ 35 mA
Working Temperature
- 10
℃
~ 55
℃
Working Humidity
Relative Hunidity:≤95%
Battery Service Life
3 years (The battery service life may be shorten due to actual using
situations.)
Size(Diameter*height)
Φ87mm x H35mm
Sensor Operations
Smoke Alarm
In standby mode, when the smoke particles in the smoke sensor reach a specified concentration, the alarm enters the alarm
mode.
Alarm mode: The buzzer will beep, and the LED indicator flashes red quickly.
Silence
In alarm mode, short press the Button to silent the alarm(the hush period is 10 minutes.)
Note: after the alarm is silenced, if the smoke concentration that caused the alert continues, the alarm will reactive in 10 minutes.
Reset
When in hush mode, short press the Button, and the alarm resumes to the standby mode.
in alarm mode, if the smoke dissipates, the alarm mode will be deactivated and the alarm will automatically resume to the standby
mode.
Test
Check whether the buzzer and LED indicator light are working properly or not.
in standby mode, short press the Button, the alarm enters the test mode.
Test mode: The buzzer beeps for 5 times, and the indicator light alternatively flashes red, green and yellow for two times, which
indicates that the buzzer and the LED indicator are working properly.