monitoring,  and  a  master  display  in  a  1RU  Chassis  then  the  recommended 
requirements would be: 
 
 

4 off PM-2E/PM-4 Modules 
1 off MD-2 Modules 

 

1 off FB-9 Flexi-box 

 

1 off FP-9 Flexipanel 

 

 

 
Software Requirements

  

 
There are no special software requirements. The system is controlled via the 
front panel, however, it may be alternatively controlled by the Eyeheight front 
panel emulator, Softpanel which runs on a PC.  
 
Chassis Types Available :- 
 

  The 1RU chassis is called a 

Flexibox

 (Order code FB-9) This will hold 

a maximum of 6 PM-2E/PM-4 Modules 

 

  The Desktop Chassis is called a 

Minibox

 (Order code MB-9) This will 

hold one  PM-2E/PM-4  Module. The  Minibox  has a  very  limited  control 
surface as standard. Using this control surface you can only recall the 
3 Pre-set memories available on the PM-2E/PM-4.  

 

 

 

Figure 3 Flexibox with Flexipanel fitted 

Summary of Contents for BM-2

Page 1: ...enhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com www eyeheight com GeNETics Product Information User Guide For BM 2 PM 2E PM 4 Audio monitor Revision1 25 February 2002 eyeheight ...

Page 2: ...ct 7 Installing the PM 2E PM 4 into a Flexibox 7 CHP 100 SDI TC GPI Card 8 Jumper Links on the Timecode and GPI I O card 8 Rear 25W D Type connection AUX 8 Manual Control of the PM 2E PM 4 10 Operational Menus for the PM 2E PM 4 10 Technical Specification for the PM 2E PM 4 13 Jumpering the I BUS CAN BUS Termination 13 Figure 1 PM 2E PM 4 Module 4 Figure 2 A typical PM 2E PM 4 displays 4 Figure 3 ...

Page 3: ... error occurs The main features are as follows The PM 2E monitors embedded audio channels 1 and 2 the PM 4 monitors AES 1 channels 1 and 2 The user can define a 6 digit channel Ident definable in foreground colour background colour flashing or normal mode All the error messages can be user defined in foreground colour background colour flashing or normal mode and whether that condition triggers an...

Page 4: ...he PM 2E PM 4 include the following Automatic monitoring of a SDI channel and flagging suitable alarms to alert the operator in user defined situations Figure 2 A typical PM 2E PM 4 displays Hardware Requirements The PM 2E PM 4 is a module and requires both a chassis and a control surface to function For example if the user required four channel SDI Section 2 Applications for the PM 2E PM 4 Sectio...

Page 5: ...e no special software requirements The system is controlled via the front panel however it may be alternatively controlled by the Eyeheight front panel emulator Softpanel which runs on a PC Chassis Types Available The 1RU chassis is called a Flexibox Order code FB 9 This will hold a maximum of 6 PM 2E PM 4 Modules The Desktop Chassis is called a Minibox Order code MB 9 This will hold one PM 2E PM ...

Page 6: ...ght Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Figure 4 Minibox Front and Rear ...

Page 7: ...w these instructions 1 On the rear of the flexibox are 6 slots for Products Remove any pair of spare blanking plates one above another There are 2 M2 5 Screws which require unfastening for each blanking plate 2 Slide the Product PCB into the spare slots and firmly push it home 3 Use the two thumbscrews to fasten the unit in place Take care that the ribbon cable for the upper circuit board stays at...

Page 8: ...elay Output 3 LK4 Set to Top Polarity selection for GPI Relay Output 4 Diagram of a GPI Output GPI1 4 Rear 25W D Type connection AUX Pin Function 1 General Purpose Output 1a GPO1a Isolated Relay closure AUDIO ALARM 2 General Purpose Output 1b GPO1b Isolated Relay closure 3 General Purpose Output 2a GPO2a Isolated Relay closure AUDIO ALARM ACCEPT 4 General Purpose Output 2b GPO2b Isolated Relay clo...

Page 9: ...e Output 8 GPO8 Open Collector Output 100mA 13 General Purpose Input 1 GPI1 Pull to Ground to activate ACCEPT ALARM 14 General Purpose Input 2 GPI2 Pull to Ground to activate 15 General Purpose Input 3 GPI3 Pull to Ground to activate 16 General Purpose Input 4 GPI4 Pull to Ground to activate 17 General Purpose Input 5 GPI5 Pull to Ground to activate 18 General Purpose Input 6 GPI6 Pull to Ground t...

Page 10: ...adjusted using the rotary digipots The Menus define all of the adjustable operational parameters in the PM 2E PM 4 Pressing the rotary digipots brings the parameter to its default value Device selection is done using the device select switches which when pressed will offer the name of the device in the LCD Window Modules can be acquired and then de acquired using the set up switch For a full descr...

Page 11: ...the audio scales 6 Ovrlay level 0 100 Default is 100 The fade level of the audio bars and audio scales 7 SPARE Menu Num Heading Automation Function 8 Audio Bar Vert Horz Default is Vertical Selects whether the audio bard are horizontal or vertical 9 Audio size 1 7 to Full default is Full The length of the audio bars The following options are available 1 7 1 6 1 5 1 3 and Full 10 Audio Width 1 999 ...

Page 12: ...t H posn 0 999 Default is 15 This sets the horizontal position of the Ident bar on the video image 21 Ident V posn 0 999 Default is 65 This sets the vertical position of the of the Ident bar on the video image 22 Text H size 0 2 Default is 1 This sets the horizontal size of the text 23 Text V size 0 1 Default is 0 This sets the vertical size of the text Menus 20 23 Top Level Menus Ident H posn 15 ...

Page 13: ...umper Configurable outputs One BNC not used SDI Output Jitter The system will add less than 0 2UI to the input Jitter This is only guaranteed on issue 2 or later cards Current Consumption 800mA at 5V Size 215mm by 100mm Jumpering the I BUS CAN BUS Termination The I BUS Network is the control system under which all Products and Panels are networked together Under certain circumstances it is necessa...