4.3 iANT100 Cable Loss
Cable length 900MHz 1800MHz 2GHz
2.5GHz 5GHz
5.8GHz
1m
0.36dB
0.53dB
0.55dB 0.62dB 0.91dB 0.98dB
3m
1.07dB
1.58dB
1.66dB 1.87dB 2.72dB 2.94dB
5m
1.78dB
2.63dB
2.77dB 3.12dB 4.53dB 4.91dB
8m
2.84dB
4.20dB
4.43dB 4.99dB 7.24dB 7.85dB
10m
3.55dB
5.25dB
5.54dB 6.24dB 9.10dB 9.81dB
4.4 iANT101 Specifications
iANT101 2.4GHz
iANT101 5GHz
iANT101 437/458.5/466MHz
Power
Max power 1 Watt continuous
ATEX: Maximum threshold
power must not exceed 2W EIRP
when taking antenna gain into
account. Software RF Power
control settable by the user is
not permitted
Max power 1 Watt continuous
ATEX: Maximum threshold power
must not exceed 2W EIRP when
taking antenna gain into account.
Software RF Power control settable
by the user is not permitted
Max power 1 Watt continuous
ATEX: Maximum threshold power must
not exceed 2W EIRP when taking
antenna gain into account. Software RF
Power control settable by the user is
not permitted
Dimensions
250mm Length, 38mm Diameter 250mm Length, 38mm Diameter
330mm Length, 38mm Diameter
Weight
480g Not including Cable
480g Not including Cable
510g Not including Cable
Connections
Please Specify with Order
Please Specify with Order
Please Specify with Order
Frequency
2300 - 2500MHz
5150 - 5875MHz
437/458.5 MHz/466MHz
Bandwidth
+/- 100MHz
Suitable for Bands A, B and C
+/- 3MHz
Impedance
50 Ohms
50 Ohms
50 Ohms
Return Loss
Better than
–
12 dB over
bandwidth
Better than
–
12 dB over bandwidth
Better than
–
14 dB over bandwidth
Gain
5 dBi @ 2.4 GHz
8 dBi @ 5.8 GHz
0dBi @ 437/458.5/466MHz
Horizontal
Radiation Pattern
Omni-directional
Omni-directional
Omni-directional
Vertical 3dB
Beam-width
Approx 34
o
Approx 16
o
Approx 80
o
Radiator Element
Brass tubing, copper plated steel
rod
PCB and Brass Rod
Brass Tubing & Helical Element
Ambient
Temperature
-40
C to 60
C
-40
C to 60
C
-40
C to 60
C
IP Rating
IP66
IP66
IP66
Certification
Number
Sira 11ATEX3100X
IECEx SIR 11.0045X
Sira 11ATEX3100X
IECEx SIR 11.0045X
Sira 11ATEX3100X
IECEx SIR 11.0045X
ATEX Certification
II 2GD Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
II 2GD Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
II 2GD Ex e IIC T6 Gb
(Ta = -40°C to +60°C)
Ex t IIIC T85°C Db IP66
Summary of Contents for iANT100
Page 1: ...Operating Manual iANT100 iANT101...
Page 20: ...Operating Manual 20 Figure 5 Figure 6 Figure 7...
Page 21: ...Operating Manual 21 Figure 8 Figure 9...
Page 25: ...Operating Manual 25 8 EC Declaration of Conformity...
Page 26: ...Operating Manual 26...
Page 27: ...Operating Manual 27 9 ATEX IECEx CERTIFICATION...
Page 28: ...Operating Manual 28...
Page 29: ...Operating Manual 29...
Page 30: ...Operating Manual 30...
Page 31: ...Operating Manual 31...
Page 32: ...Operating Manual 32...
Page 33: ...Operating Manual 33...