XTP SR HDMI Scaling Receiver • Installation
10
RS-232 and IR Over XTP Communication
The RS-232 and IR Over XTP connector is for pass-through transmission of serial signals,
such as projector control signals, and infrared data. To pass bidirectional serial command
signals between XTP-compatible devices, connect a control device to the three poles
(Tx, Rx, and G) under “RS-232” of the 5-pole captive screw connector. To transmit and
receive IR signals, connect a control device to the three poles (G, Tx, and Rx) under “IR.”
The ground (G) pole is shared.
NOTE:
RS-232 and IR data can be transmitted or received simultaneously (see figure 6
below for wiring considerations).
Tx/Rx
Pins
Rx
Tx
RS-232
IR
Rx
Tx
Tx
Rx
Rx
Tx
IR Device
RS-232 Device
G
G
G
Figure 6.
Wiring the RS-232 and IR Over XTP Connector
ATTENTION:
The length of the exposed wires in the stripping process is important.
ATTENTION :
La longueur des câbles exposés est importante lorsque l’on entreprend
de les dénuder.
•
The ideal length is 3/16 inch (5 mm).
•
La longueur idéale est de 5 mm (3/16 inches).
•
If the exposed portion is longer, the wires may touch, causing a short circuit
between them.
•
S’ils sont un peu plus longs, les câbles exposés pourraient se toucher et provoquer
un court circuit.
•
If the exposed wires are shorter, they can be easily pulled out, even if tightly
fastened by the captive screws.
•
S’ils sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les
vis captives.