3
Product Category
Mounting to a Dropped Ceiling
2
3
4
1
Figure 2.
Mounting the WAP 100AC to a dropped ceiling
To mount the unit, follow these instructions:
1.
Decide whether you need the 9/16 inch or 15/16 inch T-rail connectors and whether you need to use the spacers to
accommodate ceiling tiles.
If you do not need the spacer, use the shorter (P2.6 x 10) screws. If you require the spacers, use the longer (P2.6 x 25) screws.
2.
Connect the cables. The WAP 100AC can use a PoE injector (recommended by Extron) or a 12 VDC desktop power supply.
ATTENTION:
•
Do not connect either power supply before reading the Attention notifications in the Power Supply section of the
WAP 100AC User Guide
.
•
Ne branchez pas de sources d’alimentation externes avant d’avoir lu les mises en garde dans la section « sources
d’alimentation » du
WAP 100AC User Guide
.
•
Disconnect power from either power supply before making any connections.
•
Débranchez de sources d’alimentation externes avant d’effectuer n’importe quelles connexions.
3.
Align the T-rail clips (figure 3,
2
) with the T-rail (
1
) and
press the unit until the clips snap into place.
4.
Power on the PoE injector or 12 VDC power supply.
You are now ready to configure the WAP 100AC (see
Configuring the WAP 100AC
on page 5).
Extron provides a mounting
hardware kit that includes:
1
Two
P2.6 x 10 screws
2
Two
P2.6 x 25 screws
— used with spacers.
3
Two
9/16 inch (1.43
cm) T-rail connectors
Two
15/16 inch (2.38
cm) T-rail connectors
(not shown)
4
Two
Spacers
1
1
2
2
3
3
Figure 3.
Attaching the WAP 100AC to a T-rail
Kensington Lock
For added security, once the installation is complete, attach a Kensington Security Lock (not provided) to the metal-reinforced slot
on the top of the unit (see figure 3,
3