background image

 

8

For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the 

Extron Safety and Regulatory Compliance Guide

 on the Extron website.

 © 2018 Extron Electronics — All rights reserved.  

www.extron.com

 

All trademarks mentioned are the property of their respective owners.

TLP Pro 725C Series • Setup Guide (Continued)

Base Panel Features

e

e

LAN / PoE

275 mA

USB

RESET

MENU

D

D E

E

A

AB

BC

C

Figure 11. 

TLP Pro 725C Base Panel

A

 

LAN/PoE port

   — The TLP Pro 725C must be powered through this port (see 

Step 9 — Connecting the TLP Pro 725C

 on the 

previous page for details)

.

B

 

USB port

 — Compatible with USB 2.0.

C

 

Reset LED

 — Provides feedback about the reset status when the user presses the 

Reset

 button (see “Reset Modes: a Brief 

Summary”).

D

 

Reset button

 — Pressing the 

Reset

 button allows the unit to be reset in any of three different modes (for an overview, see 

“Reset Modes: a Brief Summary”).

E

 

Menu button

 — Pressing the 

Menu

 button activates the setup menu (see “Setup Menu”).

Reset Modes: a Brief Summary

These touchpanels provide the following reset modes (see the 

TLP Pro 725C Series User Guide

 for complete information):

• 

Use Factory Firmware

 — With the unit powered off, press and hold the 

Reset

 button (see figure 11, 

D

) while reapplying power 

to the unit. Use this mode with Toolbelt software to replace firmware in the event of conflicts arising from uploading a firmware 
update.

• 

Reset All IP Settings

 — Press and hold the 

Reset

 button for 6 seconds. After the Reset LED (

C

) flashes twice, release and 

momentarily press the 

Reset

 button. Use this mode to reset all network settings without affecting user-loaded files.

• 

Reset to Factory Defaults

 — Press and hold the 

Reset

 button for 9 seconds. After the Reset LED flashes three times, release 

and momentarily press the 

Reset

 button. Use this mode to return the touchpanel to factory default settings.

• 

Enable or Disable the DHCP Client

 — This mode toggles between DHCP enabled and DHCP disabled.

figure 11

Setup Menu

Press the 

Menu

 button (figure 11, 

E

) to open the 

setup menu. Figure 12 shows the 

Status

 screen. 

Select any of the five available screens (

Status

Network

Display

Audio

, and 

Advanced

) by 

pressing the appropriate button in the navigation bar 
at the top of the screen (for more information, see the 

TLP Pro 725C Series User Guide

).

Status

Display

Audio

Advanced

Exit

Network

Info

Model:

TLP Pro 725C

Part Number: 60-1564-02
Firmware

Version:

1.02.0001-b001

Network

IP Address:
DHCP:
Host Name:

Off

192.168.254.251

TLP-AB-CD-EF

Display

Resolution:
GUI Project:
Sleep Timer:

1024x600
N/A
5 Minutes

Audio

Master Volume:
Master Mute:

Off

99

Advanced

Controller IP:

N/A

Project Size:

N/A

Bootloader

Version:

1.03.0000

Figure 12. 

Setup Menu: Status Screen

68-3319-50 Rev. A

09 18

Summary of Contents for TouchLink TLP Pro 725C Series

Page 1: ...el Toolbelt Provides device discovery device information firmware updates and configuration of network settings system utilities and user management for TouchLink Pro devices Global Scripter Provides an integrated development environment for Extron control systems programming NOTE All four software programs are available from www extron com Obtain the following network information from your networ...

Page 2: ...tor to the LAN and power it on see figure 9 Set up the Touchpanels for Network Communication Connect the PC that you are using for setup the control processor and the touchpanel to the same Ethernet subnetwork Use the Setup Menu see page 8 or Toolbelt to set the DHCP status and if necessary the IP address subnet mask gateway and related settings for the touchpanel Configure the Touchpanels The GUI...

Page 3: ...C Series User Guide There are three methods for cutting the hole in the table Using a hand router Recommended method Use the Extron TLP Pro 725C routing template see Installation Routing Templates for Cable Cubby Series 2 Enclosures at www extron com Refer to the Routing Template User Guide available at www extron com to prepare the template and use the template to cut the hole NOTE The metal rout...

Page 4: ...Guide and Retractors User Guide at www extron com Step 5 Assemble Pass through Cable Module Optional 1 Pass the cables through the connectivity module from the bottom see figure 5 1 2 Insert the cable into the grommet plate 2 3 Fill any unused holes with the provided plugs 3 4 Attach the grommet plate to the top of the connectivity module using four of the provided 4 40 thread forming screws 4 To ...

Page 5: ...on secteur autre que le modèle Cable Cubby AC Power Module To install the power cable pass through or AAP modules follow these instructions 1 Insert the module into the cable cubby figure 7 1 Make sure the mounting holes on the module line up with the holes on the Cable Cubby enclosure If you are installing retractors they should be secured using the lowest level of mounting holes inside the touch...

Page 6: ...d and ensure that the lever is down Slide the clamp all the way up against the bottom of the table Ensure the TLP Pro 725C is firmly seated in the table Rotate the lever up to secure the enclosure 2 1 3 Lever Figure 8 Mounting the TLP Pro 725C Enclosure Locking Plate NOTE To lower the side clamp turn the lever down then press and hold the locking plate while sliding down the clamp 2 Rotate the sid...

Page 7: ...l and at least 15 from the center axis When no motion has been detected for a user defined period of time the touchpanel enters sleep mode When motion is detected by the sensor the screen display is restored and active C Communication LED This LED shows the configuration and connection status of the touchpanel Unlit during normal operation the touchpanel is configured and connected to an IP Link P...

Page 8: ... to the unit Use this mode with Toolbelt software to replace firmware in the event of conflicts arising from uploading a firmware update Reset All IP Settings Press and hold the Reset button for 6 seconds After the Reset LED C flashes twice release and momentarily press the Reset button Use this mode to reset all network settings without affecting user loaded files Reset to Factory Defaults Press ...

Reviews: