background image

TLP Pro 525, 725, and 1025 Series Web Page

To access the touchpanel default web page, enter the IP address of the unit into the web 
browser of a PC connected to the same subnet. A log‑in page opens.

Figure 18. 

TLP Pro 1025T Login Page

Figure 18 shows the login page for the TLP Pro 1025T. The login pages for the other touchpanels 
are very similar.
Enter the 

Username

 and 

Password

. The factory configured passwords for all accounts on 

this device have been set to the device serial number. Passwords can be changed during 
configuration. Passwords are case sensitive.

NOTE:

  If the device is reset to default settings, the passwords are reset to the default 

password, which is 

extron

 (for either 

admin

 or 

user

).

 

TLP Pro 525, 725, and 1025 Series Touchpanels • Configuration Software

24

Summary of Contents for TLP Pro 1025 Series

Page 1: ...TLP Pro 525 725 and 1025 Series User Guide TouchLink TouchLink Pro Touchpanel Control Systems 68 2831 01 Rev G 09 21 ...

Page 2: ... lorsqu il est utilisé sur le produit signale à l utilisateur des instructions d utilisation ou de maintenance importantes qui se trouvent dans la documentation fournie avec l équipement Pour en savoir plus sur les règles de sécurité la conformité à la réglementation la compatibilité EMI EMF l accessibilité et autres sujets connexes lisez les informations de sécurité et de conformité Extron réf 68...

Page 3: ...dvanced Digital Sync Processing AVEdge CableCover CDRS Class D Ripple Suppression Codec Connect DDSP Digital Display Sync Processing DMI Dynamic Motion Interpolation Driver Configurator DSP Configurator DSVP Digital Sync Validation Processing EQIP Everlast FastBite Flex55 FOX FOXBOX IP Intercom HelpDesk MAAP MicroDigital Opti Torque PendantConnect ProDSP QS FPC QuickSwitch Front Panel Controller R...

Page 4: ...les These limits provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications There is no guarantee that interference will not occur If this equipment does cause interference to radi...

Page 5: ...diation exposure NOTE For more information on safety guidelines regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and Regulatory Compliance Guide on the Extron website Complies with 21 CFR 1040 10 and 1040 11 Produit laser de classe 1 Si ce produit a besoin d un quelconque entretient celui ci doit être fait par Extron Electronics et son personnel q...

Page 6: ... Any other installation or use will violate FCC Part 15 regulations Compliance IC Canada Industry Canada IC Notices CAN ICES 3 B NMB 3 B This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired op...

Page 7: ...des applications extérieures fait l objet d une licence Note du ministère ISDE Canada relative aux antennes En vertu de la réglementation d Industrie Canada cet émetteur radio doit être utilisé uniquement avec une antenne d un certain type et d un gain maximal ou inférieur approuvé pour l émetteur par le ministère Afin de réduire les éventuelles interférences électromagnétiques préjudiciables aux ...

Page 8: ... paths that do not have variables are written in the font shown here Reply from 208 132 180 48 bytes 32 times 2ms TTL 32 C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH R Data STX Command ETB ETX Selectable items such as menu names menu options buttons tabs and field names are written in the font shown here From the File menu select New Click t...

Page 9: ...ng the TLP Pro 525M 725M and 1025M 28 Mounting to a Wall Box or Junction Box 28 Mounting to Drywall 30 Mounting the Touchpanels with Optional Kits 30 Mounting the TLP Pro 525T 725T or 1025T 30 Desktop Mounting 30 Reference Material 31 Best Practices for Cleaning Your Extron Products 31 Network Port Requirements and Licensed Third Party Software Used by the Touchpanels 31 Digital I O Port Cases 32 ...

Page 10: ...TLP Pro 525 725 and 1025 Series Touchpanels Contents x ...

Page 11: ... and 1025T NC models Unless otherwise stated The term touchpanel refers to all models Wall mountable models refers to the TLP Pro 525M TLP Pro 525M NC TLP Pro 725M TLP Pro 725M NC TLP Pro 1025M and TLP Pro 1025M NC Tabletop models refers to the TLP Pro 525T TLP Pro 525T NC TLP Pro 725T TLP Pro 725T NC TLP Pro 1025T and TLP Pro 1025T NC The term TLP Pro 725T refers to the TLP Pro 725T and the TLP P...

Page 12: ...th the optional mounting kits see www extron com Mounting options for TLP Pro 525T Series TLP Pro 725T Series and TLP Pro 1025T series Sit on a tabletop fixed 65 viewing angle Threaded holes in baseplate allow for secure mounting to a table Can be used with the optional SMA 2 Swivel Mount Adapter Compatible with the full range of Extron IPL Pro and IPCP Pro control processors Allows easy integrati...

Page 13: ...layer Extron IN1608 MA Switcher with DTP Extension TCP IP Network Document Camera Extron FF 220T Ceiling Speakers Extron DTP HDMI 4K 330 Rx Receiver CATx Cable VGA HDMI HDMI HDMI HDMI Extron IPCP Pro 250 IP Link Pro Control Processor MODEL 80 FLAT PANEL Extron TLP Pro 725T 7 TableTop TouchLink Pro Touchpanel Figure 1 Application Diagram Requirements Software For a complete list of the requirements...

Page 14: ... following network information from your network administrator Dynamic Host Configuration Protocol DHCP status on or off If DHCP is off you also require IP address Subnet mask Gateway User name This can be either admin or user Password The factory configured passwords for all accounts on this device have been set to the device serial number Passwords can be changed during configuration Passwords a...

Page 15: ...that you are using for setup the Extron control processor and the touchpanel to the same Ethernet subnetwork Use the Setup Menu see page 14 or Toolbelt to set the DHCP status and if required the IP address subnet mask gateway and related settings for the touchpanel 5 Configure or program the Touchpanels the GUI Designer Help File the Global Configurator Plus and Professional Help File the Global S...

Page 16: ...25T right Front Panels A LCD touchscreen Made with tough scratch resistant touchscreen TLP Pro 525 Series 5 inch touchscreen with 800x480 WVGA resolution TLP Pro 725 Series 7 inch touchscreen with 1024x600 WSVGA resolution TLP Pro 1025 Series 10 1 inch touchscreen with 1280x800 WXGA resolution B Motion sensor two The sensor detects motion between 3 to 5 feet 0 9 to 1 5 meters from the TLP and at l...

Page 17: ...e settings configured using the Setup Menu E Front status light The TLP Pro 525M 725M and 1025M two LEDs one on each side The TLP Pro 525T 725T and 1025T have a single LED in the center of the bottom edge The lights can blink or remain lit steadily and they can light red or green The lights can be configured using Global Configurator or programmed using Global Scripter to provide feedback informat...

Page 18: ... G H H H I I I J J J K K K D D D D D D D D D D D D TLP Pro 725M C C C A A AB B B H H H H H H E E E F F F G G G D D D D D D K K K D D D D D D I I IJ J J TLP Pro 1025M K K K G G G L L L TLP Pro 725T A MENU button G USB port see page 10 B RESET button H Speaker see page 10 C Reset LED see next page I Slot for mounting plate see page 10 D Mounting slots see next page J Mounting screw see page 10 E Dig...

Page 19: ...d Logic State Notes Logic Low Externally shorted to ground Logic High Open 5V from pull up resistor See Digital I O Port Cases on page 32 for examples of how these ports function F LAN PoE connector TLP Pro 525M 725M and 1025M only These touchpanels must be powered by Power over Ethernet PoE see Connecting Power on page 12 ATTENTION Do not power on the touchpanels or control processors until you h...

Page 20: ...six LEDs three on each side of the rear panel The TLP Pro 1025M has a single LED strip on each side The TLP Pro 525T TLP Pro 725T and TLP Pro 1025T have a single LED top center of the rear panel The lights can blink or remain steadily lit and they can light red or green The lights can be configured using Global Configurator or programmed using Global Scripter to provide feedback information about ...

Page 21: ...e RESET button allows the unit to be reset in any of three different modes and can also be used to toggle between enabling and disabling the DHCP client see Reset Modes on page 33 C Cable guide The Ethernet cable is inserted through this hole at the back of the base see LAN PoE connector on page 9 D RESET LED Provides feedback about the reset status when the user presses the RESET button see Reset...

Page 22: ...ork The yellow LED blinks to indicate that data is being passed to or from the touchpanel F Speaker A single speaker provides audible feedback for the user Connecting Power These touchpanels must be powered by Power over Ethernet PoE Users must provide their own PoE power injector Figure 5 shows the Extron XTP PI 100 Your power injector may look different 1 Connect a straight through Ethernet cabl...

Page 23: ...upply voids all regulatory compliance certification and may cause damage to the supply and the end product Utilisez toujours une source d alimentation fournie ou recommandée par Extron L utilisation d une source d alimentation non autorisée annule toute conformité réglementaire et peut endommager la source d alimentation ainsi que le produit final If not provided with a power supply this product i...

Page 24: ... any changes and closes the menu screens Status Press the Status button in the navigation panel at the top of any screen to open the Status screen Status Display Audio Advanced Exit Network Info Model TLP Pro 525M Part Number 60 1561 02 Firmware Version 1 00 0001 b003 Network IP Address DHCP Host Name Off 192 168 254 251 TLP AB CD EF Display Resolution GUI Project Sleep Timer 800x480 N A 5 Minutes...

Page 25: ...AC Address TLP AB CD EF 192 168 254 251 255 255 255 0 0 0 0 0 00 05 A6 AB CD EF Revert Apply 127 0 0 1 Figure 7 Network Screen 1 If IP addresses are assigned by DHCP press On If IP addresses are assigned manually press Off When DHCP is off the Host Name is grayed out and cannot be edited All addresses can be edited as shown in figure 7 When DHCP is on the Host Name can be edited The addresses are ...

Page 26: ...o enter the 89 but the 2 cannot be entered When a valid 3 digit value is entered the next octet is automatically selected c Press OK to save the changes and return to the Network screen or press Cancel to return to the Network screen without saving the changes 4 If you have changed any of the values in the Network screen the background color of the button changes to blue Press Apply to apply the n...

Page 27: ...n the ambient light LCD Brightness Use the slider control to adjust the screen brightness between 0 and 100 Wake on Motion Toggle between On and Off For this to work the touchpanel must be in sleep mode If Wake on Motion is on and the touchpanel is in sleep mode any motion detected by the motion sensor B wakes the panel from sleep mode The screen lights and all buttons become functional If Wake on...

Page 28: ...he other sound volume settings For example if the system volume is set to 80 80 percent of maximum even when the sound volume is set to 100 it is equivalent to only 80 percent of maximum Click Sets the volume for audible feedback that accompanies events such as a screen button being pressed Sound Sets the volume of audio from any audio file playback Click on the Speaker icon at the bottom of each ...

Page 29: ... 02 12 2016 1024x600 01 00 16 Project Size 12 MB 115 MB Storage Size Project Usage 0 Communication LED Rear Status Lights Enable Disable Enable Disable Figure 13 Advanced Screen TLP Pro 725M Status Display Audio Advanced Exit Network System Touchpanel Name Controller Name Controller IP TLP AB CD EF IPCP 505 North Hall 192 168 254 11 Global Configurator Project Name NorthHall Version 01 00 1383 Cre...

Page 30: ... the PINs The fourth circle appears momentarily and then the screen changes to Confirm New Menu Pin 3 Enter the PIN a second time When the PIN entered on the second occasion matches the PIN entered on the first occasion the PIN is set and the dialog closes Rear Status Lights These lights can be switched on or off by pressing the Enable or Disable button TLP Pro 725M and TLP Pro 1025M series only C...

Page 31: ...d Global Scripter are used to design the touchpanel screen and assign functions to the screen elements Installing Software The TLP Pro 525 725 and 1025 series touchpanels are compatible with GUI Designer Global Configurator Plus and Professional Global Scripter and Toolbelt All four software products can be downloaded from www extron com NOTE Ensure you are downloading the correct software These t...

Page 32: ... menu generates a list of software products with that initial letter Scroll through the search results until you find the desired product Click Download and on the new page provide the information requested An executable file exe is placed in your default Downloads folder NOTES If you select Global Configurator Plus and Professional there is a check box that allows you to download Toolbelt at the ...

Page 33: ...ty for control of an AV system as it grows and evolves GUI Designer Use the GUI Designer software to design the screen layout for the touchpanel See the GUI Designer Help File for step by step instructions and more detailed information Global Configurator Plus and Professional Use the Global Configurator Plus and Professional software to assign functions to the text and graphics of the interface S...

Page 34: ...T The login pages for the other touchpanels are very similar Enter the Username and Password The factory configured passwords for all accounts on this device have been set to the device serial number Passwords can be changed during configuration Passwords are case sensitive NOTE If the device is reset to default settings the passwords are reset to the default password which is extron for either ad...

Page 35: ...here is a single page most of which is read only providing general and network information about the unit Use the Setup Menu see page 14 or Toolbelt to configure the touchpanel network settings Use Toolbelt to upgrade the unit firmware see Updating the Firmware on the following page TLP Pro 525 725 and 1025 Series Touchpanels Configuration Software 25 ...

Page 36: ...e page until you find the firmware for your TLP Pro model Figure 21 TLP Pro Firmware download 5 Click Release Notes see figure 21 1 for more information about the firmware optional 6 Click Download 2 7 Enter the required information and click the download button Go to the Downloads folder and click on the file to install the firmware on the PC By default it is stored at C Program Files x86 Extron ...

Page 37: ...rformed by qualified personnel in accordance with local and national building codes and electrical codes Toute étape structurelle et installation électrique doit être effectuée par un personnel qualifié conformément aux codes du bâtiment aux codes incendie et sécurité et aux codes électriques locaux et nationaux Do not install touchpanels in a fire resistant rated wall or partition assembly Ne pas...

Page 38: ... installed so that the long side is horizontal EU or MK 1 gang junction boxes should be installed in the standard orientation The TLP Pro 725M TLS 725M TLP Pro1025M and TLS 1025M touchpanels mount to a 2 gang junction box All four of these models use the same mounting plate see figure 22 bottom NORTH AMERICAN NORTH AMERICAN MK MK EU MK EU MK WALL WALL WALL WALL NORTH AMERICAN NORTH AMERICAN NORTH ...

Page 39: ...ad screws for mounting to MK junction boxes EU junction boxes are usually provided with their own screws 3 Run and connect cables to the back of the touchpanel see Rear Panel Features on page 8 4 Position the touch panel so that the mounting slots in the rear of the touchpanel align with the hooks on the mounting plate The TLP Pro 725M and 1025M mounting plate has four hooks 3 one in each corner t...

Page 40: ...oxes Mounting the Touchpanels with Optional Kits A number of kits are available for mounting these touchpanels see www extron com The kits must be purchased separately and installed by following the instructions provided with the kit Mounting the TLP Pro 525T 725T or 1025T The TLP Pro 525T 725T or 1025T can be placed on any suitable flat surface Desktop Mounting No mounting kit 1 1 1 Figure 24 TLP...

Page 41: ...mmonium chloride Contain 2 or less sodium hypochlorite for example 2 bleach 98 water Regardless of the device it is important to follow these general guidelines when cleaning 1 If possible unplug the device 2 Spray the cleaner on a lint free cloth until the cloth is damp 3 Do not spray the cleaner directly onto the product 4 Gently clean the product surface using the cloth Your health and safety a...

Page 42: ...ncy sensor typically supplies 24 VDC when occupancy is detected After a defined period when no occupancy is detected the sensor supplies 0 VDC Connecting a Two position Switch to the Digital I O Port 5 0 V 1k ohms SW 2 SW 1 Two position Switch Digital I O GND Voltage Protection CTL Figure 26 Connecting a Two position Switch to the Digital I O Port Port Configured Input with pullup switch 1 open sw...

Page 43: ...re reset mode and replace firmware 1 Remove power from the touchpanel 2 On the touchpanel hold down the recessed RESET button see figure 3 B while re applying power to the unit When power is restored the Reset LED lights Hold the RESET button for a further 2 seconds before releasing it The touchpanel enters factory firmware mode 3 Upload new firmware to the unit as desired see Updating the Firmwar...

Page 44: ...rt over with configuration and uploading NOTES The factory configured passwords for all accounts on this device have been set to the device serial number Passwords can be changed during configuration Passwords are case sensitive If the device is reset to default settings the password is the default password configuration The default password is extron for either admin or user accounts Activation T...

Page 45: ... an administrator Some certificates require a passphrase that is created when the certificate is created If a passphrase is required you must enter that passphrase before uploading and applying the certificate These devices support standard OpenSSL certificate encodings such as pem Privacy enhanced Electronic Mail and der Distinguished Encoding Rules file types PEM file types are ASCII encoded and...

Page 46: ...or the TouchLink Pro control systems DER Distinguished Encoding Rules file types are binary encoded and can typically have several file extension variations such as crt and cer NOTE DER encoded files files with der crt or cer extensions that are encoded in DER binary format must be converted to a PEM encoded file type pem before being used for authentication DER encoded certificates must be conver...

Page 47: ... those factors as well as look up device location and the name of the contact person for the device The SNMP controls within Toolbelt provide a way to enable or disable SNMP It also allows you to specify related information such as the name of a contact person the physical location of the unit and a community name The text that is specified in these fields is seen by the network community when the...

Page 48: ...s not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron Electronics NOTE If a product is defective please call Extron and ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714...

Reviews: