Setting the default recording destination
To choose where the recording is saved during its creation and to select the protocol for
uploading presentation recordings to a server, do the following:
1.
In the
System
Settings
page, click the
Expand
button ( ) for the
Default
Recording
Destination
pane. The pane opens.
2.
To save recordings to a single location (to use single recording mode):
a.
Verify that the
Enable
Dual
Recording
check box is disabled (unchecked).
b.
In the
Recording
Destination
drop-down list, select where recordings should
be stored as they are being made (during recording).
•
Auto
— The SMP 351 stores recordings where space is available. The SMP stores
the recording to available locations in the following order of priority: front USB > rear
USB > internal drive.
•
Internal
Drive
Only
— This forces the unit to store recordings only in its
internal storage, even if USB drives are attached to the front and rear panel ports.
•
Front
USB
Only,
Rear
USB
Only
— These options force the unit to record to a
USB drive connected to the corresponding port.
NOTE:
The SMP 351 can automatically upload recording files to a network server
only for files that are recorded to and stored on the internal drive. If you select one
of the USB-only options, files cannot be auto-uploaded to a server.
3.
To save recordings to two locations at once (to use dual recording mode):
a.
Select (check) the
Enable
Dual
Recording
check box.
•
The selection in the
Recording
Destination:
field changes to
Internal
Drive
Only
. This cannot be changed while dual recording mode is enabled.
The recording is always stored to the internal drive.
•
The
Secondary
Recording
Destination:
drop-down list is enabled.
SMP 351 • Web-Based User Interface
117