SF 3PT User Guide • Installation
13
9.
Lift one lever of one 3-pole splicing connector
1
and insert the stripped end of the red
wire into an empty pole of the connector
2
. Press the lever down to lock the red wire in
place
3
. See the figure below.
3
3
1
1
2
2
Figure 14.
3-pole Splicing Connector
Next, lift one lever of the other 3-pole splicing connector
1
and insert the stripped end
of the black wire into an empty pole of the connector
2
. Press the lever down to lock
the black wire in place
3
.
10.
Route the steel cable from the top of the compression fitting and through one side of
the steel cable guide
1
in the ceiling bracket, as shown below.
Steel
Cable
Steel Cable
Guide
Steel Cable
Anchor Screw
1
1
2
2
4
4
3
3
Side View
Figure 15.
Anchoring the Steel Cable to Ceiling Bracket
NOTE:
It is not required to remove the outer jacket from the steel cable.
Next, loosen the steel cable anchor screw
2
and pull the steel cable tightly under the
captive washer of the anchor screw, then tighten the screw
3
. Pull the free end of the
steel cable through the other cable guide in the bracket
4
.
11.
Place the speaker and cable assembly into the included bag and hang the bag close to
the ceiling box for the final installation steps.
12.
Remove the ceiling bracket from the bag and connect the speaker wires coming from
the ceiling box to the 3-pole splicing connectors on the ceiling bracket. The red speaker
wire coming from the ceiling box connects to the splicing connector wired to the red
wire, and the black speaker wire coming from the ceiling box connects to the splicing
connector wired to the black wire.
NOTE:
Each pole of the splicing connector is capable of accepting up to 12 AWG
wire.