SF 3PT User Guide • Installation
12
b.
Measure and mark 6 inches (15.2 cm) from the end of the cable,
1
. This is the
point where the cable jacket will be stripped.
Ceiling Bracket
Compression
Nut
6” (15.2 cm)
2
2
1
1
PendantConnect
Speaker Cable
Figure 5.
Ceiling Bracket Cable
c.
Remove the outer protective cable jacket and filler material at the mark you made.
Cable Jacket
(Removed)
Ceiling Bracket
Compression
Fitting
Figure 6.
Cable Bracket Cable Stripping
5.
Next, route the free end of the cable through the ceiling bracket cover plate so that the
magnetic cover plate is correctly facing the ceiling bracket to be installed.
6.
Route the free end of the cable through the bottom of the compression nut of the ceiling
bracket.
NOTE:
Be sure that the compression nut (the large bottom nut) of the ceiling
bracket has been loosened, but not removed.
7.
Pull the cable until the jacket just protrudes from the top of the compression fitting and
tighten the compression nut (see
2
in step 4b above) to secure the cable.
NOTE:
The compression nut is tight when the bottom of the compression nut (flat
part) touches the compression fitting.
Tighten to at least 30 in-lb (3.4 N
∙
m).
8.
Using the guide on the side of the splicing connector, strip .43 inch (11 mm) from the
ends of the protruding black and red wires. These wires will be inserted into the two
3-pole splicing connectors (included).
.43" (11 mm)
DO NOT TIN
the wires.