Extron electronics MTP 15HD A Series User Manual Download Page 24

20

MTP 15HD A Series • Installation and Operation

 

c

  Peaking control — Peaking affects the sharpness of a picture.  

Increased peaking can compensate for mid- and high-frequency 

detail loss from low bandwidth system components or  

capacitance in long cables.  The minimum setting (at the  

counterclockwise limit) provides no peaking.  The maximum 

setting (at the clockwise limit) provides 100% peaking.  Adjust 

this control to obtain the optimum picture sharpness.

d

  Select button (SEQ model only) — This recessed button selects 

the Red, Green, or Blue video signal to adjust and resets all three 

video signals to a skew delay of zero nanoseconds.

 

Use a small screwdriver to press and release this button to cycle 

among selecting the Red, Green, or Blue video signal to adjust.  

The selected signal is indicated by the Red, Green, and Blue 

LEDs (

e

).

N

 

The SEQ receiver automatically saves the setting for the 
video signal that is being deselected when you push this 
button or when the selection times out after 10 seconds.

 

Press and hold this button for approximately 3 seconds to set 

the skew delay for Red, Green, and Blue to zero.  The Red, 

Green, and Blue LEDs (

e

) all turn off.  Release the button.

e

  Red, Green, and Blue LEDs (SEQ model only) — These LEDs 

indicate the video signal that is selected by the Select button  

(

d

) for skew adjustment using the Delay control (

f

).  The LED 

of the selected color flashes when skew compensation for the 

selected video signal has reached the minimum or maximum 

limit.

f

  Delay (skew adjustment) control (SEQ model only) — 

This control delays the selected Red, Green, or Blue video signal 

by up to 62 nanoseconds.  The delay is applied in incremental, 

2-nanosecond steps.  Rotate the control counterclockwise to 

reduce the delay or clockwise to increase the delay.

N

 

The control turns smoothly; it does not have mechanical 
steps or high-and low-limit stops.

 

Watch the displayed image to observe the steps of delay.

 

The selected Red, Green, or Blue LED (

e

) flashes 

to indicate that the control has reached the minimum 
(counterclockwise rotation) or maximum (clockwise  
rotation) limit.

Summary of Contents for MTP 15HD A Series

Page 1: ...User s Manual High Resolution Video and Audio MTP Transmitters and Receivers MTP 15HD A Series 68 956 02 Rev E 12 09...

Page 2: ...machen da im Inneren des Geh uses dieses Produktesgef hrlicheSpannungen dienichtisoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das...

Page 3: ...ction against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in acco...

Page 4: ...mounting 9 Connections and Settings 11 Transmitter 11 Power connection 11 Video and audio connections 11 Twisted pair connection and settings 12 Receiver 13 Power connection 13 Twisted pair connectio...

Page 5: ...installation and operation of the following products MTP T 15HD A twisted pair TP transmitter MTP RL 15HD A receiver with loop through MTP RL 15HD A SEQ receiver with loop through and skew equalizati...

Page 6: ...ther compatible MTP receiver or to a daisy chain of receivers N The transmitter provides pre peaking which boosts the signal before it is transmitted The buffered output on the receiver does not provi...

Page 7: ...models but less preferable We also recommend the use of preterminated and tested cables Cables terminated on site should be tested before use to ensure that they comply with Category 5 specifications...

Page 8: ...5 m 300 90 m 400 120 m 450 135 m 1366 x 768 250 75 m 300 90 m 400 120 m 450 135 m 1400 x 1050 250 75 m 300 90 m 350 105 m 400 120 m 1440 x 900 250 75 m 300 90 m 350 105 m 400 120 m 1600 x 1200 250 75...

Page 9: ...mpatible with the maximum ambient temperature TMA specified by Extron TMA 122 F 50 C 2 Reduced air flow Installation of the equipment in a rack should be such that the amount of air flow required for...

Page 10: ...RSU 126 1U 6 inch Deep Universal Rack Shelf Kit part number 60 190 10 RSB 126 1U 6 inch Deep Basic Rack Shelf part number 60 604 11 RSU 129 1U 9 5 inch Deep Universal Rack Shelf Kit part number 60 19...

Page 11: ...the rear of the rack 1 Remove the feet from the bottom of the MTP if they are already installed 2 Mount the MTP using two 4 40 x 3 16 inch screws in opposite diagonal corners to secure the MTP to the...

Page 12: ...to the front or rear rack supports and facing either towards the front or the rear of the rack M TP SER IES Figure 3 Attaching the back of the rack kit 1 Remove the feet from the bottom of the MTP if...

Page 13: ...PEAK ON OFF MAV SERIES AV MATR IX SWITCHER I O AUD AUDIO SETU P PRESET VID IR d B d B ENTE R 2 7 6 5 2 4 1 IN PUTS OUTPUTS 8 3 1 8 6 5 4 3 7 M T P S E R I E S Rear Front Figure 4 Typical back of the r...

Page 14: ...e mounting surface until just less than 1 4 inch 6 mm of the screw head protrudes 6 For furniture mounting align the mounting screws with the slots in the brackets and place the MTP against the surfac...

Page 15: ...er supply wiring on page 16 to wire the connector Video and audio connections b Input video connector Connect a computer video source to this 15 pin HD connector for high resolution video input N Inpu...

Page 16: ...io Twisted pair connection and settings e Pre Peak switch The Pre Peak switch alters the TP signal output to correct for long cable runs See the table on page 4 for suggested switch settings based on...

Page 17: ...ed Output connector of an RL receiver to this RJ 45 female connector See TP cable termination on page 17 to wire the RJ 45 connectors g Buffered Output connector RL receivers only Connect one end of a...

Page 18: ...DIP switches item j on the page 15 Video and audio connections and settings h Output video connector Connect a projector or other high resolution video device to this 15 pin HD connector i Mono Audio...

Page 19: ...below Output signal format from the receiver Input signal format to the transmitter Receiver s DIP switch settings C Sync SOG Video RGBHV RGBS RGBHV RGsB RGBS RGsB RGsB Component S video Composite RGB...

Page 20: ...A Captive Screw Connector Tie Wrap 3 16 5 mm Max Figure 10 Power connector wiring C Power supply voltage polarity is critical Incorrect voltage polarity can damage the power supply and the MTP Identi...

Page 21: ...can power multiple Extron 12 VDC devices using only one AC power connector TP cable termination N RJ 45 termination with CAT 5 5e or 6 cable for non C7 units only or DTP26 or CAT 7 cable for C7 units...

Page 22: ...around each wire pair and the shield around the DTP26 or CAT 7 cable are all tied to the RJ 45 connectors on both ends in accordance with the connector manufacturer specifications N The audio data tha...

Page 23: ...RGB DELAY PEAKING LEVEL RED GREEN BLUE SELECT MTP SERIES 2 3 1 1 2 6 5 4 3 1 Figure 12 MTP front panels a Power LED This LED indicates power is applied to the MTP b Level control The Level control alt...

Page 24: ...ush this button or when the selection times out after 10 seconds Press and hold this button for approximately 3 seconds to set the skew delay for Red Green and Blue to zero The Red Green and Blue LEDs...

Page 25: ...ton 2 Use UTP cable test equipment or examine the displayed video image with a critical eye to determine which video signal Red Green or Blue is most shifted to the left N A crosshatch test pattern or...

Page 26: ...methods to minimize or eliminate pair skew Switch to Extron Enhanced Skew Free A V UTP cable Add a skew compensation cable equal to the length of pair skew to the output of the receiver Install a SEQ...

Page 27: ...B Y of component video 0 3 Vp p for C of S video Minimum maximum levels 0 3 V to 1 45 Vp p Impedance 75 ohms Horizontal frequency 15 kHz to 130 kHz Vertical frequency 30 Hz to 150 Hz Return loss 30 dB...

Page 28: ...p Polarity Transmitter Positive or negative follows input polarity Receivers Positive or negative switch selectable Audio Number signal type 1 set of proprietary analog signals Connectors 1 female RJ...

Page 29: ...humidity Storage 40 to 158 F 40 to 70 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing Cooling Convection no vents Mounting Rack mount Yes with optional 1U rack shelf F...

Page 30: ...s Part 12 VDC power supply 28 071 57LF MTP transmitter and receiver guide IEC power cord Rubber feet Accessories Accessories Part number PS 124 Multiple Output 12 V DC Power Supply 60 1022 01 RSU 129...

Page 31: ...hanced Skew Free A V 1000 bulk Non Plenum 22 141 03 Extron Enhanced Skew Free A V 1000 bulk Plenum 22 142 03 N DTP26 or CAT 7 cables are recommended for C7 systems only DTP26 cable DTP26 1000 Non Plen...

Page 32: ...ai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification...

Page 33: ...SA Canada Only 1 919 863 1794 1 919 863 1797 FAX Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 F...

Reviews: