![Extron electronics MLS 608 D SA User Manual Download Page 78](http://html1.mh-extra.com/html/extron-electronics/mls-608-d-sa/mls-608-d-sa_user-manual_2457066078.webp)
Command
ASCII Command
(host to switcher)
Response
(switcher to host)
Additional
Description
RGB Delay Time
NOTE:
RGB delay affects only inputs 1-3 and if they are configured to RGB format.
Set RGB delay
EX$
D
}
Dly
X$]
Set RGB delay to (
X$
x
0
.5) seconds.
View setting
E
D
}
X$]
View RGB delay setting.
MTP Output Pre-peaking
Set output
pre-peak on
E
1Opek
}
Opek1
]
Turn output pre-peak on.
Set output
pre-peak off
E
0Opek
}
Opek0
]
Turn output pre-peak off
(default).
View status
E
Opek
}
1
]
or 0
]
View pre-peaking status.
MTP Input Signal Level Adjustment
Specify a value
EX1(
ILVL
}
Ilvl
X1(]
Specify an input signal
level value
X1(
.
Increment value
E
+ILVL
}
Ilvl
X1(]
Increase the signal level
value by 1.
Decrement value
E
-ILVL
}
Ilvl
X1(]
Decrease the signal level
value by 1.
View current value
E
ILVL
}
X1(]
View current level
X1(
.
MTP Input Signal Peaking Adjustment
Specify a value
EX1^
IPEK
}
Ipek
X1^]
Specify an input peaking
value
X1^
.
Increment value
E
+IPEK
}
Ipek
X1^]
Increase value by 1.
Decrement value
E
-IPEK
}
Ipek
X1^]
Decrease value by 1.
View current value
E
IPEK
}
X1^]
View current
X1^
.
NOTE:
X$
= RGB delay for inputs 1-3: maximum delay is 5 seconds, in 0.5 second intervals, default = 0 seconds
X1^
= Input signal peaking adjustment range: 0 to 255 (default = 0)
X1(
= Input signal level adjustment range: 0 to 255 (default = 60)