![Extron electronics MLS 608 D SA User Manual Download Page 73](http://html1.mh-extra.com/html/extron-electronics/mls-608-d-sa/mls-608-d-sa_user-manual_2457066073.webp)
X4#
= Executive mode (front panel lock): 0 = off (all unlocked, default), 1 = lockout all (input buttons
and encoders), 2 = lockout input buttons only
X4$
= Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 28800, 38400 (default),
57600, 115200
X4%
= Parity,
O
dd,
E
ven,
N
one (default),
M
ark,
S
pace, (only use first letter, for example
N
=
N
one)
X4^
= Data bits: 7, 8 (default = 8)
X4&
= Stop bits: 1, 2 (default = 1)
X4*
= Verbose mode: 0 = no verbose mode and non-tagged responses for queries, 1 = verbose
mode and non-tagged responses for queries (default), 2 = no verbose and tagged responses
for queries, 3 = verbose mode and tagged responses for queries
X4(
= Mute status: 0 = mute off, 1 = mute on (default)
X5)
= Mute value: +00000 = off, +00001 = on (default)
X5!
= Mic number: 40100 = Mic 1, 40101 = Mic 2
X5@
= Alpha numeric up to 24 characters. No special characters except hyphen (-). No lower/upper
case distinction, no blanks or spaces. First character must be alpha, last cannot be hyphen
X5#
= Alpha numeric name. Combination of unit name and last three pairs of unique alpha-numeric
characters (for example MLS-608-D-MA-06-DE-2E.
MLS 608 D Series • SIS Programming and Control
67