7

Cabling and Features

Attach cables using the following wiring diagrams as a guide. Full details are available in the 

MLC Plus 84 Series User Guide

.

ATTENTION:

 

• 

Installation and service must be performed by authorized personnel only.

• 

L’installation et l’entretien doivent être effectués par le personnel autorisé uniquement.

Power

The MLC Plus 84 supports Power over Ethernet (PoE) (see 

Control and Power — LAN (Ethernet) and PoE

 on the next page). 

Alternatively, you can power the controller using an optional Extron 12 VDC, 0.5 A desktop power supply, as shown below.

Tx Rx G

POWER

12V        

0.4A MAX

COM 1

Ridged

Smooth

 External Power Supply

(12 VDC, 0.5 A max.)

Ground all devices.

– Return

+12 VDC input

Ridged

Smooth

To 

AC 

power

Rear Panel

Power Input, External Power Supply (optional)

• Front panel buttons blink 

during boot-up.

• Once the MLC Plus 84 is 

powered and operational, the 

buttons are lit according to 

configuration, and “Display” 

and “Volume” are backlit.

• Connect to an Extron 

12 VDC, 0.5 A power 

supply.

• If PoE is available, the 

MLC Plus 84 uses PoE, 

otherwise it uses power 

via this port. 

Tie Wrap

3/16"
(5 mm)
Max.

NOTE:

  Check the polarity of the power supply 

before connecting it to the controller.

 

Control and Power — LAN (Ethernet) and PoE

 

Pins:

12345678

MLC Plus 84 

Side Panel

Insert Twisted

Pair Wires

LAN/PoE (Ethernet and Power Over Ethernet)

Connect to an Ethernet network with a straight through cable. This port must be configured.

NOTE:

 

MAC address information 
(

00-05-A6-##-##-##

is located on the bottom of 
the rear enclosure.

Link LED:

 Lights green 

to indicate a network 
connection.

Activity LED:

 Blinks yellow 

to indicate data is being 
sent or received.

Default protocol:

• MLC Plus 84 IP address: 192.168.254.

250

• Gateway IP address: 0.0.0.0

• Subnet mask: 255.255.255.0

• DNS address: 127.0.0.1

• DHCP: off

• Link speed and duplex level: 

autodetected

• Data rates: 10/100Base-T

Use this port to upload configuration files 

and firmware.

Power over Ethernet (PoE):

• If PoE is available, the MLC Plus 84 uses PoE.
• If PoE is dropped (disconnects), the controller switches seamlessly 

to the external 12 VDC power supply, if it is installed.

Default login credentials:

• Username: 

admin

  

• Password: 

extron

MAC: 00-05-A6-

XX-XX-XX

S/N:  #######    E######

00-05-A6-XX-XX-XX

MAC: 00-05-A6-

XX-XX-XX

S/N:  #######    E######

MAC
Address

Ethernet

PC

TCP/IP

Network

Extron Devices 

(Switchers, Scalers)

ATTENTION:

 

• 

Power over Ethernet (PoE) is intended for indoor use only. It is to be connected only to networks or circuits that are not 
routed to the outside plant or building.

• 

L’alimentation via Ethernet (PoE) est destinée à une utilisation en intérieur uniquement. Elle doit être connectée 
seulement à des réseaux ou des circuits qui ne sont pas routés au réseau ou au bâtiment extérieur.

ATTENTION:

 

• 

Always use a power supply provided 
by or specified by Extron. Use of an 
unauthorized power supply voids all 
regulatory compliance certification and 
may cause damage to the supply and 
the end product.

• 

Utilisez toujours une source 
d’alimentation fournie ou recommandée 
par Extron. L’utilisation d’une source 
d’alimentation non autorisée annule 
toute certification de conformité 
réglementaire et peut endommager la 
source d’alimentation que l’unité.

Rev. C, 09/2018: 

Updated French text.

Rev. C, 

09/2018: 
Changed 
1 A power 
supply to 
0.5 A supply, 
replaced 
isometric 
image with 
orthographic 
image.

Rev. C, 09/2018: 

Removed TIA/EIA 
wiring tables.

Summary of Contents for MLC Plus 84 EU

Page 1: ...Extron Control apps for remote control applications Global Configurator and other useful software applications are available at www extron com Installation Step 1 Get Ready Use the following check list to prepare for the installation Download and install the latest version of the following Toolbelt software for discovering the controller and other control products on the network for managing core ...

Page 2: ...lus 84 Read any installation instructions and regulatory guidelines that come with the mounting devices raceway junction box surface mounting box before installing the raceway or box Select and prepare the site before cabling the controller This may include cutting a hole in the installation surface or installing a cabling raceway running the cables to that site installing the wall box and pulling...

Page 3: ...all the MLC Plus 84 securely so it cannot easily be removed after installation hold and install the bracket so that the side labeled Front faces out toward you and the unlabeled side faces the wall or furniture To install the MLC Plus 84 so it can be removed easily hold and install the bracket so the unlabeled side faces outward toward you and the side labeled Front faces the wall or furniture Wal...

Page 4: ...ob c Insert the tip of a small flat bladed screwdriver such as an Extron Tweeker through one of the slots at the sides of an EU or MK model faceplate as shown at right There are four slots per faceplate two on each side d Press the tab into the body of the MLC Plus 84 to release the faceplate from the circuit board e Repeat steps 1c and 1d with the remaining slots and tabs around the edges of the ...

Page 5: ...he tabs are inserted into the slots and the ridge on each tab snaps into place in the faceplate NOTE It is important to make sure that ALL eight tabs are securely snapped into place 5 If reattaching the volume control faceplate place the knob back on its shaft and use the small Allen wrench to tighten the set screw to secure the knob VOLUME MUTE DISPLAY OFF ON PC DOC CAM LAPTOP 1 LAPTOP 2 HDMI VGA...

Page 6: ...ith Wall Frames Rear Panel Features RESET LAN PoE POWER 12V 0 4A MAX Tx Rx G Tx Rx G 1 2 C G C V G S COM 1 COM 2 VOL IR G IN D IN RELAYS RESET LAN PoE POWER 12V 0 4A MAX Tx Rx G Tx Rx G 1 2 C G C V G S COM 1 COM 2 VOL IR G IN D IN RELAYS Power input connector COM RS 232 ports IR output port Relay ports Reset LED Reset button Digital input port Volume control port LAN PoE Ethernet connector and LED...

Page 7: ...on the bottom of the rear enclosure Link LED Lights green to indicate a network connection Activity LED Blinks yellow to indicate data is being sent or received Default protocol MLC Plus 84 IP address 192 168 254 250 Gateway IP address 0 0 0 0 Subnet mask 255 255 255 0 DNS address 127 0 0 1 DHCP off Link speed and duplex level autodetected Data rates 10 100Base T Use this port to upload configurat...

Page 8: ...rce Device Two Single IR Emitters Ground IR Output Ground IR Output Unidirectional IR or 3 16 5 mm max To Projector Panel Display or the Wired IR Remote of a Source Device IR Output Port Output options IR 30 kHz to 300 kHz with or without carrier signals Ground IR Signal Dual IR Emitter Control Unidirectional Digital Input 1 2 C G C V VOL G IN D IN RELAYS Digital Input Configure the port with or w...

Page 9: ...close as possible to the amplifier to avoid picking up background noise via the cable NOTE When audio mute is active the MLC Plus 84 sets output voltage to 0 VDC even if the voltage range minimum and maximum voltage limits have been set to levels above zero such as 2 V to 8 V Step 5 Set up the MLC Plus 84 for Network Communication 1 Connect the PC that you will use for setup and the MLC Plus 84 to...

Page 10: ...ch touchpanels to interact with Whom to notify how and under what circumstances a Configure ports on the controller Select device drivers and link them to each assigned serial IR or Ethernet port Select settings serial protocol relay behavior digital input volume control settings as needed b Set up monitors schedules macros and local variables c Set up the front panel buttons assign appropriate co...

Page 11: ...all frame to the mounting bracket metal which you attached to the mounting surface during site preparation see Site Preparation on page 2 2 Holding the wall frame in place on the bracket press the cabled MLC Plus 84 into the frame until the two tabs on either side of the unit snap into the opening of the bracket holding the MLC Plus 84 in place MLC Plus 84 EU VOLUME MUTE DISPLAY OFF ON PC DOC CAM ...

Page 12: ...he Reset LED blinks 6 times if the DHCP client is enabled The Reset LED blinks 3 times if the DHCP client is disabled NOTES DHCP toggle mode is supported on firmware version 3 00 0000 or higher By default DHCP is off and the unit uses a static IP address When you disable DHCP the unit uses the factory default IP address 192 168 254 250 Reset All IP Settings Press and hold the rear panel Reset butt...

Page 13: ...ed for the previous generation IP Link non Pro controllers are not compatible Removing the MLC Plus EU or MK from the Mounting Surface Before you can replace buttons or faceplates on an MLC Plus 84 EU or MK if the unit is installed in a wall or furniture you must remove the unit from the metal mounting bracket and installation surface To help with this task Extron provides a removal tool shown at ...

Page 14: ...p 4 Cable the MLC Plus 84 then apply power Cable all devices see step 4 Step 2 Prepare the installation site Step 1 Get ready Step 3 Change buttons or faceplates if desired Step 8 Mount the MLC Plus 84 Create monitors schedules timers macros and local variables Build and upload the configuration to the controller Step 6 If desired or required install a new security certificate via Toolbelt Within ...

Reviews: