4-7
MAV 44 / 48 / 84 / 88 Matrix Switchers
•
Remote Operation
Command/response table for SIS commands (cont’d)
Command
ASCII Command Response
Additional description
(host to switcher)
(switcher to host)
IR receiver enable
Enable IR receiver
0*65#
IRdisable*0
Enable the IR receiver (allow
control by the IR 501).
Disable IR receiver
1*65#
IRdisable*1
Disable the IR receiver (do not
allow control by the IR 501).
Read IR receiver enable
65#
X10
0= enable, 1 = disable (default).
Global presets
Save
current configuration as preset
X11
,
Spr
X11
Command character is a comma.
Example:
8
,
Spr08
Save current ties as preset 8.
Recall a preset
X11
.
Rpr
X11
Command character is a period.
Example:
5
.
Rpr05
Recall preset 5, which becomes
the current configuration.
View global preset
configuration
Esc X11
VC
X2
1
•
X2
2
•
X2
3
•...•
X2
n
•Vid•
X2
1
•
X2
2
•
X2
3
•...•
X2
n
•Aud
n is the highest output number
for this model switcher. Show
preset
X11
’s video and audio
configuration. Show the video
input tied to n sequential outputs
and then the audio input tied to
n sequential outputs.
Response description:
Video input # (I#) assigned to Output # (O#1)•I# assigned to O#2...I# assigned to O#8•Vid•
Audio I# assigned to O#1•I# assigned to O#2...I# assigned to O#8•Aud
Example (MAV 88 AV):
Esc
4VC
1
Output:
Response = tied input:
Input 5 video tied to output 2
2 3 4 5 6 7 8
1 2 3 4
6•5•6•8•3•3•1•0•Vid•8•1•1•1•8•8•8•8•Aud
5 6 7 8
No tied input Audio input 8 tied to output 5
Each position shown in the response is an output: left = output 1, right = output 8. The number in each position is the
input tied to that output. Global preset 4 makes the following ties:
Video — Input 6 is tied to outputs 1 and 3; input 5 to output 2; input 8 to output 4; input 3 to outputs 5 and 6; and
input 1 to output 7. No input is tied to output 8.
Audio — Input 8 is tied to outputs 1 and outputs 5 through 8; input 1 to outputs 2 through 4.
Example (MAV 44 V):
Esc
4VC
Output:
Response = tied input:
Input 1 tied to output 2
1•1•0•2•Vid
1 1 1 1
Front panel security lockout (
Executive
mode)
Lock front panel
1X
Exe1
Enable executive mode.
Unlock front panel
0X
Exe0
Disable executive mode.
Read
front panel lockout status
X
X8
1= executive mode on,
0 = executive mode off.
Summary of Contents for MAV 44 Series
Page 1: ...MAV 44 48 84 88 Series Matrix Switchers 68 777 01 Rev D 10 07...
Page 4: ......
Page 11: ...MAV 44 48 84 88 Matrix Switchers 1 Chapter One Introduction About the Switchers Features...
Page 16: ...Introduction cont d MAV 44 48 84 88 Matrix Switchers Introduction 1 6...
Page 56: ...Operation cont d MAV 44 48 84 88 Matrix Switchers Operation 3 32...