MAV 44 / 48 / 84 / 88 Matrix Switchers • Operation
Resetting audio gain — single input
Reset a specified input’s audio gain or attenuation to the factory default (-12 dB for
captive screw audio connector [A] models, 0 dB for RCA audio connector [A RCA]
models) as follows:
1
.
Press and hold the Audio Setup (I/O) button for approximately 2 seconds
until the Audio Setup LED lights (figure 3-36).
AUDIO SETUP
AUDIO SETUP
The LED lights to indicate Audio Setup mode.
Release the Audio Setup button.
2 seconds
Press and hold the button.
Figure 3-36 — Select
Audio
Setup
mode
2
.
Press and release the Input 5 button (figure 3-37).
6
5
4
INPUTS
2
1
4
3
OUTPUTS
+dB
- dB
= lit, = unlit
Press and release the Input 5 button.
The Input 5 LED lights to
indicate that input 5 is selected.
The –dB LED
indicates a negative
(attenuation) level.
In this example, the LEDs indicate audio attenuation in the –1 dB to –5 dB range.
The Output 1, Output 2, and Output 3
LEDs display the input's audio level range.
Figure 3-37 — Select an input
3
.
Press and release the
and
buttons simultaneously (figure 3-38).
Simultaneously press and release the
button and button.
AUDIO SETUP
The Audio Setup
LED blinks off
and then relights.
Figure 3-38 — Reset the selected input level
4
.
If desired, reset other inputs’ audio levels by repeating steps 2 and 3.
After approximately 30 seconds of front panel inactivity, the switcher saves the
most recent input gain or attenuation levels and exits Audio Setup mode.
Summary of Contents for MAV 44 Series
Page 1: ...MAV 44 48 84 88 Series Matrix Switchers 68 777 01 Rev D 10 07...
Page 4: ......
Page 11: ...MAV 44 48 84 88 Matrix Switchers 1 Chapter One Introduction About the Switchers Features...
Page 16: ...Introduction cont d MAV 44 48 84 88 Matrix Switchers Introduction 1 6...
Page 56: ...Operation cont d MAV 44 48 84 88 Matrix Switchers Operation 3 32...