![Extron electronics IN1604 DTP User Manual Download Page 59](http://html1.mh-extra.com/html/extron-electronics/in1604-dtp/in1604-dtp_user-manual_2457039059.webp)
IN1604 DTP and IN1604 HD Scalers • Configuration Software
53
Reset Device
This option opens a dialog box to confirm the resetting of device settings.
From the
Device
drop-down menu, select
Reset Device...
. The Reset Device dialog box
opens.
Figure 28.
Reset Device Dialog Box
The reset changes all device settings to the factory defaults. It is the same as the
E
ZXXX
}
SIS command (see
Reset SIS commands
on page 45).
To reset the connected device, click the
Reset
button. To exit the Reset Device dialog box
without making any changes, click the
Cancel
button.
Backup and Restore
This option saves current configurations and restores saved configurations.
From the
Device
drop-down menu, click
Backup and Restore...
. The System Backup
and Restore dialog box opens.
Figure 29.
Backup and Restore Dialog Box
To save the current configuration settings to an external file:
1.
In the Backup panel, click the
Browse
button. The Save As window opens.
2.
Navigate to the desired save location on the host device and click the
Save
button. The
window closes.
3.
Click the
Backup
button to save the configuration to an external file on the host device.
4.
Click the
Close
button to close the System Backup and Restore window.
To restore a saved configuration settings file:
1.
In the Restore panel, click the
Browse
button. The Open window opens.
2.
Navigate to the save location of the saved file and click the
Open
button. The Open
window closes.
NOTE:
Valid configuration files have a .extz file extension.
3.
Click the
Restore
button to apply the saved configuration settings.
4.
Click the
Close
button to close the System Backup and Restore window.