Error Responses
When the scaler receives a valid command, it executes the command and sends a
response to the host device. If the unit is unable to execute the command, it returns an error
response tot he host.
E01
— Invalid input number
E13
— Invalid parameter
E06
— Invalid switch attempt in this mode
E14
— Not valid for this configuration
E10
— Invalid command
E17
— Invalid command for signal type
E11
— Invalid preset number
E22
— Busy
E12
— Invalid port number
SIS Overview
Using the Command and Response Tables
The
Command and Response Tables
for SIS commands beginning on page 33 lists
the commands that the scaler recognizes as valid, the responses that are returned to the
host, a description of the command function or the results of executing the command, and
examples of commands in ASCII (Telnet) and URL encoded (Web).
NOTE:
Upper and lower case text can be used interchangeably unless otherwise
stated.
ASCII to Hex Conversion Table
•
Space
Figure 19.
ASCII to Hexadecimal Character Conversion Table
Symbol Definitions
•
= Space
]
= Carriage return with line feed
}
= Carriage return with no line feed
| = Pipe (can be used interchangeably with the
}
character)
E
= Escape
W = Can be used interchangeably with the
E
character
X!
= Input selection
1
= configurable VGA
2
= HDMI/DVI 1
3 = HDMI/DVI 2
4
= HDMI/DVI 3