![Extron electronics HDP 101 4K User Manual Download Page 5](http://html1.mh-extra.com/html/extron-electronics/hdp-101-4k/hdp-101-4k_user-manual_2456375005.webp)
5
HDP 101 4K • User Guide (Continued)
Command and Response Table for SIS Commands
]
=
Carriage return and line feed (LF)
}
=
Carriage return with no line feed
|
= Pipe (can be used interchangeably with the
}
character).
•
=
Space
E
= Escape key
W
= Can be used interchangeably with the
E
character.
X!
= Status
0
= Off/low/undetected
1
= On/high/detected
X$
=
EDID:
1
to
3
(see table)
X$
Slot
Default EDID
Details
1
Input 1 (Store) Slot
HDMI 1080p 60 Hz 2-Ch
Default
2
Output
3
User Loaded Slot
Manually populated via PCS
X%
= Verbose mode:
0
= Clear/none
1
= Verbose mode (default)
2
= Tagged responses for queries
3
= Verbose mode and tagged responses for queries
X^
=
HDP 101 4K part number
60-1739-01
X&
= Text string of up to 24 alphanumeric characters and hyphen (-). No spaces allowed, and no distinction between upper and
lower case. First character must be a letter and the last must not be a hyphen. Default is “
HDP-101-4K
”.
NOTE:
Upper- and lowercase characters can be used interchangeably in the command field unless otherwise specified.
X(
= Input HDCP status
0
= No source is detected
1
= Source detected with HDCP*
2
= Source detected without HDCP*
*Active source detection based on PLL clock or TMDS lock (not solely based on +5VDC presence).
X1)
= Output HDCP status:
0
= No sink connected**
1
= HDCP sink detected
2
= Sink detected without HDCP
** For active sink, it needs to have hotplug detect and DP termination (monitor sense).
X#
=
Video color bit depth mode:
1
= Automatically based on sink EDID (default)
2
= Force 8-bit
X@
= DP output format:
1
= Auto (default)
2 = DP RGB "Full"
3 = DP RGB "Limited"
4
= DP YUV 444 "Limited"
5
= DP YUV 422 "Limited"