Command and Response Table for SIS Commands (continued)
DTP2 T 202 FB • Remote Control
25
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
5V output hot plug mode
Set 5V output mode to auto
E
M1HPLG
}
HplgM1
]
Set 5V output mode to always on
E
M2HPLG
}
HplgM2
]
View 5V output mode
E
MHPLG
}
X1&]
Verbose 2/3:
HplgM
X1&]
Device name
Set the unit name
EX1*
CN
}
Ipn
•
X1*]
Change the name to one of your choosing.
Set unit name to factory default
E
•
CN
}
Ipn
•
DTP2
-
T
-
202
-
FB
]
Set name to default.
View unit name
E
CN
}
X1*]
Verbose 2/3:
Ipn
•
X1*]
Reset
Reset to factory setting
E
ZXXX
}
Zpx
]
Reset to factory defaults.
Information requests
Information request
I
In
X!
•
Aflw
X!
•
Ausw
X@
•
Vmt
X1@
•
Amt
X1#]
Example:
I
In1
•
Aflw2
•
Ausw1
•
Vmt1
•
Amt0
]
Input 1 is selected, analog audio is assigned to
input 2, the switcher is in auto-input switching
(HDMI) mode, video is muted and analog
audio is unmuted.
Request part number
N
60-
nnnn
-
nn
]
See
www.extron.com
for part numbers.
Request name
1I
DTP2
•
T
•
202
•
FB
]
Verbose 2/3:
Inf01*DTP2
•
T
•
202
•
FB
]
Request description
2I
DTP2
•
HDMI/DP
•
FB
•
Tx
•
SUPPORT
•
4K60
]
Verbose 2/3:
Inf02*DTP2
•
HDMI/DP
•
FB
•
Tx
•
SUPPORT
•
4K60
]
Query controller firmware version
Q
X1(]
Query firmware version with build
*Q
X2)]
Verbose mode
NOTE:
If tagged responses are enabled (modes 2 and 3), all “view” commands return the prefix and the value, just as the “set”
commands do. For example, the View front panel switch mode (
E
AUSW
}
) command returns “
Ausw
X@]
”.
Set verbose mode
EX2!
CV
}
Vrb
X2!]
Read verbose mode
E
CV
}
X2!]
KEY:
X!
= Input number
1
= Input 1 (HDMI)
2
= Input 2 (DisplayPort)
X1@
= Video mute status
0
= Mute off
1
= Video and sync mute on
2
= Sync mute on
X1#
= Audio mute status
0
= Mute off
1
= Mute on
X1&
= 5V hot plug mode
1
= Auto 5V is enabled on the DTP output when a video source is present
2
= Always enabled (
default
)
X1*
= Name
A text string of up to 24 alphanumeric characters and minus sign/hyphen (-).
No blank or space characters are permitted as part of a name.
The first character must be a letter, and the last character must not be a
minus sign/hyphen
X1(
= Firmware version number to second decimal place
(x
.
xx
)
X2)
= Firmware version with build number
X2!
= Verbose mode
0
= Clear/none
1 = Verbose mode (default for RS-232 or USB) (
default
)
2
= Tagged responses for queries
3 = Verbose mode and tagged for queries
Summary of Contents for DTP2 T 202 FB