DTP2 T/R 211 • Installation and Operation
6
12.
In a DTP2 transmitter to DTP2 receiver configuration, set the SEND POWER
toggle switch
to the
UP
position on the powered DTP2 device to enable sending
remote power to the far end DTP2 device. Set the toggle switch to the
DOWN
position on
the DTP2 device receiving power (see
ATTENTION:
•
The DTP2 211 device is configured to output power to DTP2 models only. If
connected to a Legacy DTP device, set the toggle switch to the
DOWN
(
OFF
)
position. Failure to turn the power OFF will damage the connected Legacy DTP
device.
•
Le DTP2 211 est configuré pour fournir une alimentation aux modèles
DTP2 uniquement. S’il est connecté à un autre appareil, veuillez positionner
l’interrupteur à bascule sur «
DOWN
» (
OFF
). Si l’interrupteur n’est pas positionné
sur OFF, vous risquez d’entraîner la défaillance de l’appareil Legacy DTP
connecté.
13.
Connect power to the transmitter or receiver.
14.
Power on the source devices.
After the transmitter, the receiver, and their connected devices are powered up, the system
is fully operational. If any problems are encountered, ensure all cables are routed and
connected properly.
NOTE:
Ensure the video source and display selected for the DDC are properly
connected to the transmitter and receiver pair, and the transmitter, receiver, and display
have power applied
before
power is applied to the video source. If the other devices
are not turned on before the video source, the image may not appear.
Connections
Transmitter Rear Panel Connections
INPUTS
POWER
12V
0.8A MAX
SIG LINK
DTP2 OUT
OVER DTP2
RS-232
IR
Tx Rx
Tx Rx
G
AUDIO
A
A
B
B
C
C
D
D
E
E
A
Power inlet
Audio input
HDMI input
DTP2 Output RJ-45 port
Over DTP2 RS-232 and IR port
Figure 2.
DTP2 T 211 Transmitter Connectors
A
Power inlet
— Plug the included external 12 VDC power supply into either this 2-pole
inlet
or
the power inlet on the receiver (see
on page 12 to wire the connector).
NOTES:
•
One power supply is included with the transmitter and can
normally
power
both units. Remote power is only available if both the transmitter and the
receiver are from the Extron DTP2 series.
•
The power supply can be plugged into either the transmitter or the receiver to
power both units.
•
If the internal jumper setting for ground is removed, a DTP2 211 unit
cannot
remotely power the other unit, because of ground potential differences. Each
unit requires a local power supply (see
2
Summary of Contents for DTP2 R 211
Page 6: ......