Extron DTP T UWP 4K D Series • Remote Control
19
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Reset
Reset to factory setting
E
ZXXX
}
Zpx
]
Reset to factory defaults
Information requests
Information request
I
In
X!
Vid
•
In
X!
Aud
•
Ausw
X@
•
Vmt
X#
•
Amt
X(]
View/Read EDID in HEX format
E
R
X!
EDID
}
X1$]
Read data as text from the EDID assigned
and used on input
X!
View EDID native resolution
E
N
X!
EDID
}
X1^]
Read out native resolution and refresh
rate from the EDID assigned to the
specified input in plain text.
Example:
1920x1200
@60Hz
Request part number
N
60-
nnnn
-
nn
]
See
www.extron.com
, for part
numbers
Query firmware version
Q
x
.
xx
]
Query firmware version w/build
*Q
x
.
xx.xxxx
]
Verbose mode
NOTE:
If tagged responses are enabled (modes 2 and 3), all “view” commands return the prefix and the value, just as the “set” commands do.
For example, the view auto switch mode (
E
AUSW
}
) command returns “
Ausw
X@]
” in verbose mode 2/3.
Set verbose mode
EX1&
CV
}
Vrb
X1&]
Read verbose mode
E
CV
}
X1&]
0
= clear/none
1 = verbose mode (
default
)
2 = tagged responses for queries
3 = verbose mode and tagged for queries
NOTES:
X!
= Input number
X@
= Auto switch mode
X#
= Video mute
X(
= Status
X1$
= Raw EDID data
X1^
= Current EDID native resolution and refresh rate in plain text
1
through max number of outputs
0
= disabled/off/undetected (
default
)
1
= enabled/on/detected
2
= enabled (lowest active input has priority)
0
= disabled (
default
)
1
= enabled (highest active input has priority)
2
= enabled (lowest active input has priority)
0
= off, disabled, or not detected
1
= on, enabled, or detected
128 or 256 bytes of hexadecimal data
Summary of Contents for DTP T UWP 4K 232 D