Safety Instructions

Safety Instructions • English

WARNING:

 

This symbol, 

, when used on the product, is intended to 

alert the user of the presence of uninsulated dangerous voltage within 
the product’s enclosure that may present a risk of electric shock.

ATTENTION:

  This symbol, 

, when used on the product, is intended 

to alert the user of important operating and maintenance (servicing) 
instructions in the literature provided with the equipment.

For information on safety guidelines, regulatory compliances, EMI/EMF 

compatibility, accessibility, and related topics, see the Extron Safety and 

Regulatory Compliance Guide, part number 68-290-01, on the Extron 

website, 

www.extron.com.

Sicherheitsanweisungen • Deutsch

WARNUNG:

  Dieses Symbol 

 auf dem Produkt soll den Benutzer 

darauf aufmerksam machen, dass im Inneren des Gehäuses dieses 
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und 
die einen elektrischen Schlag verursachen können.

VORSICHT:

  Dieses Symbol 

 auf dem Produkt soll dem Benutzer in 

der im Lieferumfang enthaltenen Dokumentation besonders wichtige 
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.

Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,  

EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in 

den Extron-Richtlinien für Sicherheit und Handhabung  (Artikelnummer  

68-290-01) auf der Extron-Website, 

www.extron.com

.

Instrucciones de seguridad • Español

ADVERTENCIA:

  Este símbolo, 

, cuando se utiliza en el producto, 

avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del 
producto, lo que puede representar un riesgo de descarga eléctrica.

ATENCIÓN:

 

Este símbolo, 

, cuando se utiliza en el producto, avisa 

al usuario de la presencia de importantes instrucciones de uso y 
mantenimiento recogidas en la documentación proporcionada con el 
equipo.

Para obtener información sobre directrices de seguridad, cumplimiento 

de normativas,  compatibilidad electromagnética, accesibilidad y temas 

relacionados, consulte la  Guía de cumplimiento de normativas y seguridad 

de Extron, referencia 68-290-01, en el sitio Web de Extron, 

www.extron.com

.

Instructions de sécurité • Français

AVERTISSEMENT :

 

Ce pictogramme, 

, lorsqu’il est utilisé sur le 

produit, signale à l’utilisateur la présence à l’intérieur du boîtier du 
produit d’une tension électrique dangereuse susceptible de provoquer 
un choc électrique.

ATTENTION :

  Ce pictogramme, 

, lorsqu’il est utilisé sur le produit, 

signale à l’utilisateur des instructions d’utilisation ou de maintenance 
importantes qui se trouvent dans la documentation fournie avec le 
matériel.

Pour en savoir plus sur les règles de sécurité, la conformité à la 

réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets 

connexes, lisez les informations de sécurité et de conformité Extron, réf. 

68-290-01, sur le site Extron, 

www.extron.com

.

Istruzioni di sicurezza • Italiano 

AVVISO:

  Questo simbolo, 

,quando viene utilizzato il prodotto, serve 

ad avvisare l’utente della presenza di tensioni pericolose non isolate 
all’interno del prodotto, che può presentare un rischio di scosse 
elettriche.

ATTENTZIONE:

 

Questo simbolo, 

, quando viene utilizzato il 

prodotto, serve ad avvisare l’utente di importanti istruzioni di uso e 
manutenzione (assistenza) nella letteratura fornita con l’apparecchiatura.

Per informazioni sulle linee guida di sicurezza, adempimenti normativi, 

compatibilità EMI/EMF, accessibilità e argomenti correlati, vedere la sicurezza 

di Extron e Regulatory Compliance Guide, parte numero  

68-290-01, sul sito Web Extron, 

www.extron.com

.

Instrukcje bezpieczeństwa • Polska  

OSTRZEŻENIE

Ten symbol,

 

,

 gdy używany na produkt, ma na celu 

poinformować użytkownika o obecności izolowanego i niebezpiecznego 

napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie 

porażenia prądem elektrycznym.

UWAGI: 

Ten symbol, 

, gdy używany na produkt, jest przeznaczony do 

ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji 

(obsługi) w literaturze, wyposażone w sprzęt.

Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji 

wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne, 

zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część 

numer 68-290-01, na stronie internetowej Extron, 

www.extron.com

.

Инструкция по технике безопасности 

 Русский

ПРЕДУПРЕЖДЕНИЕ: 

Данный символ, 

, если указан на продукте, 

предупреждает пользователя о наличии неизолированного опасного напряжения 
внутри корпуса продукта, которое может привести к поражению электрическим 
током.

ВНИМАНИЕ:   Данный символ, 

, если указан на продукте, 

предупреждает пользователя о наличии важных инструкций 
по эксплуатации и обслуживанию в руководстве, 
прилагаемом к данному оборудованию.

Для получения информации о правилах техники безопасности, 
соблюдении нормативных требований, электромагнитной 
совместимости (ЭМП/ЭДС), возможности доступа и других 
вопросах см. руководство по безопасности и соблюдению 
нормативных требований Extron на сайте Extron: 

,  

www.extron.com

, номер по каталогу - 68-290-01.

安全说明

 

 

简体中文

 

警告

产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,

有触电危险。

注 意

产 品 上 的 这个 标 志 意 在 提 示 用 户 设 备 随 附 的 用 户 手 册 中 有 

重要的操作和维护(维修)说明。

关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍 
使用的特性等相关内容,敬请访问 

Extron 

网站 

www.extron.com

,参见 

Extron

 安全规范指南,产品编号 

68-290-01

Summary of Contents for DTP T UWP 4K 232 D

Page 1: ...User Guide DTP T UWP 4K D Series HDMI Transmitters HDMI Twisted Pair Extender Transmitters 68 3157 01 Rev A 12 17...

Page 2: ...n referencia 68 290 01 en el sitio Web de Extron www extron com Instructions de s curit Fran ais AVERTISSEMENT Ce pictogramme lorsqu il est utilis sur le produit signale l utilisateur la pr sence l in...

Page 3: ...EMI EMF Extron www extron com Extron 68 290 01 EMI EMF www extron com Extron Safety and Regulatory Compliance Guide P N 68 290 01 EMI EMF Extron www extron com Extron 68 290 01...

Page 4: ...ners The following registered trademarks registered service marks SM and trademarks TM are the property of RGB Systems Inc or Extron Electronics see the current list of trademarks on the Terms of Use...

Page 5: ...ide the character 0 is used for the number zero and O is the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here Reply from 208 132 18...

Page 6: ...Wiring 9 RS 232 Connector Wiring 10 Remote RS 232 and Contact Closure Connector 10 Over DTP RS 232 Connector 10 Operation 11 Transmitter LEDs 11 System Operation 12 Audio Configuration 12 Remote Cont...

Page 7: ......

Page 8: ...G Tx Rx Tx Rx G Tx Rx Tx Rx G HDMI A B 3 4 INPUTS OUTPUTS Tx Rx RS 232 G LAN 2x25W 8 2x50W 4 RESET AUDIO INPUTS OUTPUTS REMOTE L L 1 R R L 2 R L 3 R CLASS 2 WIRING L 4 R L 5 R 48V 48V 1 2 L R VARIABLE...

Page 9: ...HDTV video and 4K signals up to 230 feet 70 meters over STP cable DTP T UWP 4K 332 D transmitters can transmit 720p 1080i or 1080p HDTV video and 4K signals up to 330 feet 100 meters over STP cable F...

Page 10: ...with local electrical and safety codes L unit doit tre install e conform ment au National Electric Code et aux normes lectriques et de s curit locales The transmitters can be installed in a two gang...

Page 11: ...niture cut out the center portion of the template 2 Place the wall box or the full size template against the installation surface and mark the opening guidelines 3 Cut out the material from the marked...

Page 12: ...foil shield can be cut back to the point where the cable exits the cable clamp 8 Connect the cables to the rear of the unit see Rear Panel on page 7 for connector details 9 Connect front panel device...

Page 13: ...ront Panel AUTO SW CONFIG DMI IN UDIO IN HDCP 1 2 HDMI IN AUDIO IN E DTP T HWP D Front Panel B A E AUTO SW CONFIG HDMI IN AUDIO IN HDCP 1 AUDIO IN VGA IN E DTP T UWP 4K D Front Panel A A B C D Figure...

Page 14: ...captive screw connector to control switching on the unit see RS 232 Connector Wiring on page 10 to properly wire the Remote connector RS 232 To control the unit through this port connect an RS 232 dev...

Page 15: ...distances and reduce transmission errors Use the following Extron XTP DTP 24 SF UTP cables and connectors for the best performance XTP DTP 24 1000 Non Plenum 1000 305 m spool 22 236 03 XTP DTP 24P 10...

Page 16: ...tion avant de faire l installation lectrique ATTENTION Always use a power supply supplied and or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification a...

Page 17: ...3 16 inches S ils sont un peu plus longs les c bles expos s pourraient se toucher et provoquer un court circuit S ils sont un peu plus courts ils pourraient sortir m me s ils sont attach s par les vi...

Page 18: ...s A Power LEDs Two color front panel LEDs on the transmitters light to indicate signal and power status as follows Amber The unit is receiving power but there is no signal on the associated input Gree...

Page 19: ...e in one of three modes Each input can be configured individually for any of the three modes Transport embedded digital audio default The embedded digital audio content on the digital video input is t...

Page 20: ...vice such as a computer or control system via its rear panel Remote RS 232 port see item C on page 7 or front panel Configuration USB port see item D on page 6 The default serial port protocol of the...

Page 21: ...response to the host The error response codes are E01 Invalid input number E06 Invalid channel change E10 Invalid command E13 Invalid parameter E14 Not valid for this configuration E17 Invalid command...

Page 22: ...HDCP status 0 No source is detected 1 Source is detected with HDCP 2 Source detected without HDCP X1 Output HDCP status 0 No sink is detected 1 Sink is detected with HDCP support 2 Sink is detected w...

Page 23: ...mt1 Mutes video to black screen with sync Disable video mute 0b B Vmt0 Video mute status b B X VmtX Verbose mode 2 3 Output 5V mode Set output 5V mode EMX HPLG HplgMX Output 5V mode status EMHPLG X Hp...

Page 24: ...uthorization status EEHDCP X X Video breakaway Select program video input only X InX Vid View currently selected video input X Analog audio mute Mute or unmute analog audio X Z AmtX Read analog audio...

Page 25: ...n X1 Change the device name to X1 Set device name to factory default E CN Ipn DTP T UWP 4K xxx D COLOR Set device name to default Example DTP T UWP 4K 232 D COLOR View device name ECN X1 NOTES X Input...

Page 26: ...Q x xx xxxx Verbose mode NOTE If tagged responses are enabled modes 2 and 3 all view commands return the prefix and the value just as the set commands do For example the view auto switch mode EAUSW c...

Page 27: ...uter download it as follows 1 Go to www extron com and click the Download tab 2 On the Download Center screen click the Software link on the left sidebar menu 3 On the next Download Center screen loca...

Page 28: ...see figure 4 D on page 6 and to the PC with the PCS software installed Once the PCS software opens the Device Discovery screen appears To start the DTP T UWP 4K D configuration module double click on...

Page 29: ...dule Opens the About This Module dialog box with information about the PCS software module AV Controls Use the AV Controls panel to Select Input Mute Audio Mute Video Mute Audio and Video Mute Sync In...

Page 30: ...affected EDID Minder Extron EDID Minder is an EDID management process that automatically manages the EDID information between a digital display device and one or more input sources The EDID Minder tab...

Page 31: ...Image Settings NOTE The image settings on this panel only apply to the RGB VGA input Input 2 Adjust the following settings by either typing the desired values into their respective fields or using the...

Page 32: ...e General Settings tab contains Auto Switch settings and a button to access the Hardware Settings window Auto Switch Click the check box to enable auto switch and choose the Auto Switch priority by cl...

Page 33: ...t www extron com click the Download link at the top of the page figure 11 1 then click the Firmware link 2 on the left sidebar menu 2 2 1 1 3 3 4 4 5 5 Figure 11 Firmware Link on the Download Tab 2 On...

Page 34: ...rmware are also loaded Loading firmware to the transmitter To load a new version of firmware to the transmitter using PCS follow these instructions 1 If not already installed download and install the...

Page 35: ...the DTP T UWP 4K D product from the device list The DTP T UWP 4K D module opens 6 From the drop down device menu select Update Firmware to this Device The Update Firmware dialog box appears 7 Click C...

Page 36: ...cause the device to stop functioning Les fichiers firmware valides doivent contenir l extension fichier S19 Un fichier avec n importe quelle autre extension n est pas une mise jour de firmware pour c...

Page 37: ...is not full size or to scale DO NOT scale up or print to use as a template Full size templates are available at www extron com 4 26 10 82 cm 4 28 10 87 cm Recommended cut out area for the installation...

Page 38: ...lt has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications were made to the product that were not authorized by Extron NOTE If...

Reviews: