DTP Crosspoint 84 IPCP Series Matrix Switchers • Programming Guide
5
Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it performs the
command and sends a response to the host device. If the switcher is unable to perform
the command because the command is invalid or contains invalid parameters, the switcher
returns an error response to the host. The error response codes are:
E01
— Invalid input channel number (out of range)
E10
— Invalid command
E11
— Invalid preset number (out of range)
E12
— Invalid output number (out of range)
E13
— Invalid value (out of range)
E14
— Invalid command for this configuration
E22
— Busy
E24
— Privileges violation (Users have access to all view and read commands [other than
the administrator password], and can create ties, presets, and audio mutes
E25
— Device not present
E26
— Maximum number of connections exceeded
E27
— Invalid event number
E28
— Bad filename / file not found
Using the Command and Response Tables
The command and response table begins on
page 9
. Symbols used in the table represent
variables in the command and response fields. Command and response examples are
shown throughout the table. The SIS commands are
not
case sensitive. The ASCII to HEX
conversion table below is for use with the command and response table.
ASCII to Hex Conversion Table
•
Space