DTP Crosspoint 84 IPCP Series Matrix Switchers • Programming Guide
19
Remote Port Specific and Communications Protocol SIS Commands
Symbol definitions for Remote port specific SIS commands
X5)
= Password
Up to 12 alphanumeric characters
NOTE:
T
he HTML language reserves certain characters for specific functions (see
Special Characters
on page 20)
.
X5!
= Port number
01
= Remote (RS-232) port
02
—
05
= UARTs 1 — 5 (DTP input and output ports)
X5@
= Baud rate
9600
(
default
),
19200
,
38400
,
115200
X5#
= Parity
o
dd,
e
ven,
n
one,
m
ark,
s
pace (only the first letter required) (
n
= default
)
X5$
= Data bits
7
,
8
(
default
)
X5%
= Stop bits
1
(
default
),
2
NOTE:
X5!
through
X5%
and
X5*
are variables for the rear panel Remote RS-232 port. These variables are repeated on page 8 as
X3*
through
X4#
for the RS-232 inserts.
X5^
= Port type
0
= RS-232 (
default
)
1
= RS-422 (not available on DTP CrsossPoint)
X5&
= Verbose mode
0
= Clear or none (default for Telnet connection)
1
= Verbose mode (default for RS-232 or USB connection)
2
= Tagged responses for queries
3
= Verbose mode and tagged for queries
NOTE:
If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command
does (for example, the read matrix name command
E
CN
}
, returns Ipn•
X2)]
).
X5*
= Port timeout interval (in 10-second increments)
1
(= 10 seconds) -
65000
(default is
30
= 300 seconds = 5 minutes)
SIS Command and Response Table for Remote and Communications Protocol Commands
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Set administrator password
EX5)
CA
}
Ipa
•
X5)]
Read administrator password
E
CA
}
X5)]
Reset (clear) administrator password
E
•
CA
}
Ipa
•
]
Set user password
EX5)
CU
}
Ipu
•
X5)]
Read user password
E
CU
}
X5)]
Reset (clear) user password
E
•
CU
}
Ipu
•
]
Set serial port parameters
EX5!
*
X5@
,
X5#
,
X5$
,
X5%
CP
}
Cpn
X5!
•
Ccp
X5@
,
X5#
,
X5$
,
X5%]
Read serial port parameters
EX5!
CP
}
X5@
,
X5#
,
X5$
,
X5%]
Configure flow control
EX5!
*
Y8^
,
Y8&
CF
}
Cpn
X5!
•
Cfl
Y8^
,
Y8&]
Read flow control
EX5!
CF
}
Y8^
,
Y8&]
Configure receive timeout
EX5!
*
Y8*
,
Y8(
CE
}
Cpn
X5!
•
Cce
Y8*
,
Y8(
,
Y9)
,
Y9!]
NOTE:
The configure command is sufficient as shown for most users, with the priority (
Y9)
) and length or delimiter (
Y9!
) omitted).
The response in this case is “
Cpn
X5!
•
Cce
Y8*
,
Y8(
,0,00000L
]
,” with the default
Y9)
and
Y9!
values returned.
Read receive timeout
EX5!
CE
}
Y8*
,
Y8(
,
Y9)
,
Y9!]
Set mode
EX5!
*
X5^
CY
}
Cpn
X5!
•
Cty
X5^]
Read mode
EX5!
CY
}
X5^]
Set verbose mode
EX5&
CV
}
Vrb
X5&]
Read verbose mode
E
CV
}
X5&]
Configure current port timeout
E
0*
X5*
TC
}
Pti0*
X5*]
Read current port timeout
E
0TC
}
X5*]
Configure global IP port timeout
E
1*
X5*
TC
}
Pti1*
X5*]
Read global IP port timeout
E
1TC
}
X5*]