background image

 

Safety Instructions

Safety Instructions • English

WARNING: 

This symbol, 

, when used on the product, is intended to 

alert the user of the presence of uninsulated dangerous voltage within the 

product’s enclosure that may present a risk of electric shock.

ATTENTION: 

This symbol, 

, when used on the product, is intended 

to alert the user of important operating and maintenance (servicing) 

instructions in the literature provided with the equipment.

For information on safety guidelines, regulatory compliances, EMI/EMF 

compatibility, accessibility, and related topics, see the Extron Safety and 

Regulatory Compliance Guide, part number 68-290-01, on the Extron website, 

www.extron.com

.

Instructions de sécurité • Français

AVERTISSEMENT

Ce pictogramme, 

, lorsqu’il est utilisé sur le 

produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit 

d’une tension électrique dangereuse susceptible de provoquer un choc 

électrique.

ATTENTION

Ce pictogramme, 

, lorsqu’il est utilisé sur le produit, 

signale à l’utilisateur des instructions d’utilisation ou de maintenance 

importantes qui se trouvent dans la documentation fournie avec le 

matériel.

Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation, 

la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les 

informations de sécurité et de conformité Extron, réf. 68-290-01, sur le site 

Extron, 

www.extron.com

.

Sicherheitsanweisungen • Deutsch

WARNUNG:

 

Dieses Symbol 

 auf dem Produkt soll den Benutzer 

darauf aufmerksam machen, dass im Inneren des Gehäuses dieses 

Produktes gefährliche Spannungen herrschen, die nicht isoliert sind 

und die einen elektrischen Schlag verursachen können.

VORSICHT

:

  

Dieses Symbol 

 auf dem Produkt soll dem Benutzer in der 

im Lieferumfang enthaltenen Dokumentation besonders wichtige Hinweise 

zur Bedienung und Wartung (Instandhaltung) geben.

Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,  

EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in 

den Extron-Richtlinien für Sicherheit und Handhabung  (Artikelnummer  

68-290-01) auf der Extron-Website, 

www.extron.com

.

Instrucciones de seguridad • Español

ADVERTENCIA: 

Este símbolo, 

, cuando se utiliza en el producto, 

avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del 

producto, lo que puede representar un riesgo de descarga eléctrica.

ATENCIÓN: 

Este símbolo, 

, cuando se utiliza en el producto, avisa 

al usuario de la presencia de importantes instrucciones de uso y 

mantenimiento recogidas en la documentación proporcionada con el 

equipo.

Para obtener información sobre directrices de seguridad, cumplimiento 

de normativas,  compatibilidad electromagnética, accesibilidad y temas 

relacionados, consulte la  Guía de cumplimiento de normativas y seguridad de 

Extron, referencia 68-290-01, en el sitio Web de Extron, 

www.extron.com

.

Инструкция по технике безопасности 

 Русский

ПРЕДУПРЕЖДЕНИЕ: 

Данный символ, 

, если указан 

на продукте, предупреждает пользователя о наличии 
неизолированного опасного напряжения внутри корпуса 
продукта, которое может привести к поражению электрическим 
током.

ВНИМАНИЕ:  

Данный символ, 

, если указан на продукте, 

предупреждает пользователя о наличии важных инструкций 
по эксплуатации и обслуживанию в руководстве, 
прилагаемом к данному оборудованию.

Для получения информации о правилах техники безопасности, 
соблюдении нормативных требований, электромагнитной 
совместимости (ЭМП/ЭДС), возможности доступа и других 
вопросах см. руководство по безопасности и соблюдению 
нормативных требований Extron на сайте Extron: 

www.extron.com

номер по каталогу - 68-290-01.

Chinese Simplified

(简体中文)

警告

产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,

有触电危险。

注 意

产 品 上 的 这个 标 志 意 在 提 示用 户设 备 随 附 的用 户手 册 中 有 

重要的操作和维护(维修)说明。

关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍 
使用的特性等相关内容,敬请访问 

Extron 

网站 

www.extron.com

,参见 

Extron

 安全规范指南,产品编号 

68-290-01

Chinese Traditional

 )

警告

若產品上使用此符號,是為了提醒使用者,產品機殼內存在著 

可能會導致觸電之風險的未絕緣危險電壓。

注意

 

 若產品上使用此符號,是為了提醒使用者。

有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關主題的詳
細資訊,請瀏覽 Extron 網站:

www.extron.com

,然後參閱《Extron 安全性與

法規遵守手冊》,準則編號 68-290-01。

Japanese

警告:

 

この記号   が製品上に表示されている場合は、筐体内に絶縁されて 

いない高電圧が流れ、感電の危険があることを示しています。

注意: 

この記号 

 が製品上に表示されている場合は、本機の取扱説明書

に 記載されている重要な操作と保守(整備)の指示についてユーザーの 注

意を喚起するものです。

安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目に  

ついては、エクストロンのウェブサイト 

www.extron.com

 より 『

Extron Safety 

and Regulatory Compliance Guide

』 (

P/N 68-290-01

) をご覧ください。

Korean

경고:  

이 기호  , 가 제품에 사용될 경우, 제품의 인클로저 내에 있는 

접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을 

경고합니다.

주의: 

이 기호  , 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와 

있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.

안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에 

대한 자세한 내용은 Extron 웹 사이트(

www.extron.com

)의 Extron 안전 및 

규제 준수 안내서, 68-290-01 조항을 참조하십시오. 

Summary of Contents for DTP CrossPoint 84 IPCP

Page 1: ...Progamming Guide DTP CrossPoint 84 IPCP Matrix Switchers Scaling Presentation Matrix Switchers with DTP Extension 68 2349 61 Rev Ax3 07 14...

Page 2: ...f aufmerksam machen dass im Inneren des Geh uses dieses Produktes gef hrliche Spannungen herrschen die nicht isoliert sind und die einen elektrischen Schlag verursachen k nnen VORSICHT Dieses Symbol a...

Page 3: ...cher possible The rear panel Remote port and front panel Configuration port are independent of one another A front panel Configuration port connection and a rear panel Remote port connection can be ac...

Page 4: ...need the subnet mask and the gateway address If the IP address has been changed to an address comprised of words and characters you can determine the actual numeric IP address using the ping ICMP uti...

Page 5: ...time of no communications By default this timeout value is set to five minutes but the value can be changed See the Configure port timeout SIS commands on page 19 NOTE Extron recommends leaving the d...

Page 6: ...Password The switcher initiates the Password message immediately after the copyright message when the controlling system is connected using TCP IP or Telnet and the switcher is password protected Thi...

Page 7: ...range E13 Invalid value out of range E14 Invalid command for this configuration E22 Busy E24 Privileges violation Users have access to all view and read commands other than the administrator password...

Page 8: ...ected supports HDCP but the video signal is not encrypted 3 Monitor connected supports HDCP and the video signal is encrypted X1 Video format 0 Auto HDMI RGB Full to CEA sink or DVI to non CEA sink 1...

Page 9: ...tion 0 Output sync instantly disabled when no active video input is selected 001 through 500 seconds 501 Output sync never times out default X3 Screen saver status 0 Active input detected timer is not...

Page 10: ...X4 Stop bits 1 2 X4 Port timeout interval in 10 second increments 1 10 seconds 65000 default is 30 300 seconds 5 minutes NOTE X3 through X4 are variables for the RS 232 inserts These variables are re...

Page 11: ...to all outputs video only X InX Vid Audio breakaway Example 10 In10 Vid Tie input 10 video to all outputs Tie input to all outputs audio only X InX Aud Audio breakaway Read ties Read video output tie...

Page 12: ...50 Hz 56 1680x1050 60 Hz 36 1024x768 60 Hz 43 1360x768 50 Hz 50 1440x900 60 Hz 57 1920x1200 50 Hz 37 1280x768 50 Hz 44 1360x768 60 Hz 51 1600x900 50 Hz 58 1920x1200 60 Hz 38 1280x768 60 Hz 45 1366x768...

Page 13: ...deo output Example EO3 0AFMT AfmtO03 0 When audio is broken away from video use the embedded audio from the input port when creating an audio breakaway tie to output 3 View output audio breakaway sele...

Page 14: ...3 Example 0LS Input Response Status No input detected Sync detected 1 2 3 4 5 6 7 8 0 0 0 1 1 1 0 1 XTP HDBaseT XTP switch positions Check input switch position EIX1 HDBT X1 HdbtIX1 X1 Verbose mode 0...

Page 15: ...alid only in the range of 75 through 82 User EDID slots 1 through 8 Example EE75 Slot 1UNAM Unam75 Slot 1 Name EDID location 75 Slot 1 Clear EDID name EEX UNAM UnamE75 USER n n 1 through 8 Read EDID n...

Page 16: ...DTP CrossPoint firmware version Updated firmware version indicates the version running Upload date and time 1 23 1 00 1 06LX DTPCP84 Tue 08 Apr 2014 00 00 00 UTC 1 00 1 06LX DTPCP84 Mon 21 Apr 2014 1...

Page 17: ...rst active pixel in output X1 Increment value EX1 HCTR HctrX1 X2 Increment the value by one pixel shift the image to the right Decrement value EX1 HCTR HctrX1 X2 Decrement the value by one pixel shift...

Page 18: ...rates only NTSC or PAL 480p to 1080p 50 Hz or 60 Hz Set overscan value E6 X3 OSCN Oscn6 X3 Read overscan value E6OSCN X3 Save and recall scaler presets NOTE If you try to recall a scaler preset that i...

Page 19: ...IX1 1 Enable the Ethernet serial port insert on input X1 This disables the captive screw serial port insert Set all RS 232 input insertions EIX3 LRPT LrptIX3 View input insertion EIX1 LRPT X3 View all...

Page 20: ...and output ports X3 Baud rate 300 600 1200 1800 2400 3600 4800 7200 9600 14400 19200 28800 38400 57600 115200 default 9600 X4 Parity odd even none mark space only the first letter required n default...

Page 21: ...es for example the read matrix name command ECN returns Ipn X2 X5 Port timeout interval in 10 second increments 1 10 seconds 65000 default is 30 300 seconds 5 minutes SIS Command and Response Table fo...

Page 22: ...haracters The HTML language reserves certain characters for specific functions The switcher does not accept these characters as part of names passwords or locally created file names The switcher rejec...

Page 23: ...return no line feed Pipe can be used interchangeably with the character space E Escape key W Can be used interchangeably with the E character X6 Object ID gain control or mix point See the tables on p...

Page 24: ...30102 Left 30010 30110 Right 30003 30103 Right 30011 30111 Input 3 Gain Trim Input 7 Gain Trim Left 30004 30104 Left 30012 30112 Right 30005 30105 Right 30013 30113 Input 4 Gain Trim Input 8 Gain Tri...

Page 25: ...07 Virtual Returns and Expansion Inputs Gain Blocks Gain Gain Virtual Return A 50100 Expansion Input 1 50200 Virtual Return B 50101 Expansion Input 2 50201 Virtual Return C 50102 Expansion Input 3 502...

Page 26: ...4 21205 21206 21207 V rtn B 21300 21301 21302 21303 21304 21305 21306 21307 V rtn C 21400 21401 21402 21403 21404 21405 21406 21407 V rtn D 21500 21501 21502 21503 21504 21505 21506 21507 V rtn E 2160...

Page 27: ...21010 21011 21012 21013 21014 21015 Mic in 4 21108 21109 21110 21111 21112 21113 21114 21115 Virtual returns to virtual send bus mixer block G V rtn A 21208 21209 21210 21211 21212 21213 21214 21215 V...

Page 28: ...ight 60101 60301 60001 60201 Output 2 Trim Analog Volume HDMI Volume Left 60102 60002 60202 Right 60103 60003 60203 Output 3 Trim Analog DTP Analog Volume Digital DTP Left 60104 60304 60004 60204 Righ...

Page 29: ...U DsG30012 56 Set the input 7 left gain to a value of 5 6 dB Example 2 EG20800 125AU DsG20800 125 Set the mic input 1 gain to a level of 12 5 dB Read an analog DSP trim or mix point EGY6 AU X6 Object...

Page 30: ...m the level set in the Set a group fader control example above Lower a group fader control EDX6 X6 GRPM GrpmDX6 X6 Decrease the level of the X6 group fader by X6 dB View the group fader control level...

Page 31: ...d ask for an Application Engineer to receive an RA Return Authorization number This will begin the repair process USA 714 491 1500 or 800 633 9876 Europe 31 33 453 4040 Asia 65 6383 4400 Japan 81 3 35...

Reviews: