Command and Response Table for Matrix Switcher Commands (continued)
DTP Crosspoint 84 IPCP Series Matrix Switchers • Programming Guide
16
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Compound image position and size
Specify all size and position values
EX1(
,
X2(
*
X2(
*
X2(
*
X2(
XIMG
}
Ximg
X1(
,
X2(
*
X2(
*
X2(
*
X2(]
Example:
E
3,+0*+0*2000*1000XIMG
}
Ximg3,+00000*+00000*02000*01000
]
View all size and position values
EX1(
XIMG
}
X2(
*
X2(
*
X2(
*
X2(]
View active pixels and lines
View active pixels
EX1(
APIX
}
Apix
X1(
*
X3)]
NOTE:
The “
Apix
X1(
*
” portion of the response appears only when the switcher is in
Verbose
mode 2 or 3.
View active lines
EX1(
ALIN
}
Alin
X1(
*
X3)]
NOTE:
The “
Alin
X1(
*
” portion of the response appears only when the switcher is in
Verbose
mode 2 or 3.
View defaults
E
V
X1(
SPEC
}
Show active pixels, active lines, total
pixels, and total lines.
SpecV
X1(
*
X3)
*
X3)
*
X2(
*
X2(]
NOTE:
The “
SpecV
X1(
*
” portion of the response appears only when the switcher is in
Verbose
mode 2 or 3.
Aspect ratio
Set to fill
EX1(
*1ASPR
}
Aspr
X1(
*1
]
Always fill the output.
Set to follow
EX1(
*2ASPR
}
Aspr
X1(
*2
]
Follow the input aspect ratio.
View aspect ratio
EX1(
ASPR
}
X3!]
Execute Auto-Image
Execute Auto-Image
X1(
*A
Img
X1(]
Overscan
NOTE:
The Overscan command applies to SMPTE input rates only (NTSC or PAL, 480p to 1080p, 50 Hz or 60 Hz).
Set overscan value
E
6*
X3@
OSCN
}
Oscn6*
X3@]
Read overscan value
E
6OSCN
}
X3@]
Save and recall scaler presets
NOTE:
If you try to recall a scaler preset that is not saved, the matrix switcher responds with the error code E13.
Save a scaler preset
2*
X1(
*
X2@
,
2Spr
X1(
*
X2@]
Command character is a comma.
Recall a scaler preset
2*
X1(
*
X2@
.
2Rpr
X1(
*
X2@]
Command character is a period.
Example:
2*3*5.
2Rpr3*005
]
Recall preset 5, which becomes the
current configuration.
Erase a scaler preset
E
X2*
X2@
PRST
}
PrstX2*
X2@]
Show scaler preset availabilities
51#
PreI
X%
1
X%
2
X%
3
...
X%
128
]
Each
X%
is the availability status of a
scaler preset, starting from preset 1.
NOTE:
The “
PreI
” portion of the response appears only when the switcher is in
Verbose
mode 2 or 3.
Auto memories
Enable auto memories
EX1(
*1AMEM
}
Amem
X1(
*1
]
Set auto memories on. Previous settings
for the incoming signal are recalled.
Disable auto memories
EX1(
*0AMEM
}
Amem
X1(
*0
]
Set auto memories off.
Show auto memory status
EX1(
AMEM
}
X1(]
NOTE:
X%
= Available
0
= Not available
1
= Available
X1(
= TP (scaled) and insertion output number
03
or
04
X2*
= Picture adjustments
000
through
127
(
064
= default
X2(
= Position and size
±
10240
Horizontal is specified from left, vertical from top
X3)
= Active pixels and active lines
Dependent on the input signal and selected scaling.
X3@
= Overscan percentage
0
= 0% (default)
1
= 2.5%
2
= 5.0%
X3!
= Aspect ratio fill or follow
1
= fill;
2
= follow
X2@
= Scaler preset
001
–
128