Email address fields
The eight Email Address fields identify the e-mail addresses of the personnel to
whom the CrossPoint or MAV switcher BME 0 e-mails notification of its failure and
repair status. Standard e-mail address conventions (
nnnnn
@
xxx
.com) apply.
The check boxes and drop boxes associated with each address field permit the
operator to specify criteria under which the BME will e-mail recipients. In the
associated Missing Inputs drop boxes, select the inputs to monitor for presence or
absence of a signal. Check the Fans and Power boxes to monitor the cooling and
power supplies. In the associated
E-Mail Options
drop box, select whether the
recipient is to be e-mailed of failures, fixes, or both; not notified; or be removed
from the e-mail list. The
Suspend
option is useful for temporarily removing
personnel from the e-mail list when they are unavailable, such as on travel or
vacation. Deleting an e-mail addressee and clicking the
Submit
button removes the
recipient from e-mail notification completely.
Firmware Upgrade page
The Firmware Upgrade page provides a way to replace the firmware that is coded
on each BME’s control board without taking the switcher out of service. Access the
Firmware Upgrade page (figure 6-8) by clicking the
Firmware Upgrade
link on the
System Settings page.
Passwords
System Settings
Refresh
Email settings
Figure 6-8
—
Firmware Upgrade page
Update the firmware for each BME as follows:
N
The Firmware Upgrade page is
only
for replacing the firmware that controls
all switcher operation. To insert your own custom HTML pages, see “File
Management Page”, on page 6-12.
1
.
Visit the Extron Web site,
www.extron.com
, select the CrossPoint 450 Plus/
MAV Plus product category, select the latest
firmware installation package
(*.exe file) for the switcher, and download the file
. Note the folder to which you
save the firmware file.
2
.
Run the executable (*.exe) file to decompress the firmware file.
3
.
Connect the PC to the matrix switcher BME via the switcher’s LAN port.
4
.
Access the matrix switcher BME using HTML pages.
5
.
Click the
Configuration
tab.
Summary of Contents for CrossPoint 450 Plus 3248 HV
Page 1: ...CrossPoint 450 Plus Series MAV Plus series Large Scale Matrix Switchers 68 521 03 Rev B 11 09 ...
Page 4: ......
Page 10: ...Table of Contents cont d CrossPoint 450 Plus and MAV Plus Switchers Table of Contents vi ...
Page 32: ...Installation cont d CrossPoint 450 Plus and MAV Plus Switchers Installation 2 14 ...
Page 86: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 54 ...
Page 88: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 56 ...
Page 112: ...Programmer s Guide cont d CrossPoint 450 Plus and MAV Plus Switchers Programmer s Guide 4 24 ...
Page 183: ...B 15 CrossPoint 450 Plus and MAV Plus Switchers Reference Information Button label blanks ...