![Extron electronics CrossPoint 450 Plus 3248 HV User Manual Download Page 101](http://html.mh-extra.com/html/extron-electronics/crosspoint-450-plus-3248-hv/crosspoint-450-plus-3248-hv_user-manual_2456132101.webp)
4-13
CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide
Command/response table for SIS commands (continued)
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Save, recall, and directly write presets (continued)
Write room outputs
EX1)
,
X@
1
,
X@
2
,
...
X@
n
MR
}
See notes below.
Mpr
X1)
,
X@
1
,
X@
2
,
...
X@
n
]
N
• The maximum number of rooms (
X1)
) is 10.
•
A room can contain a maximum of 16 outputs (
X@
s).
•
An output can belong to only one room.
•
If you try to save a room preset for a room that has not been created, the switcher responds with the error code E11.
•
If no room name is assigned, the default name (
X1!
) is “Room #
X1)
•
X@
1
,•
X@
2
,•
X@
3
”.
Example:
E
8
,
3
,
04
,
5
,
6MR
}
Mpr8
,
03
,
04
,
05
,
06
]
Outputs 3, 4, 5, and 6 are
assigned to room 8.
Read room outputs
EX1)
MR
}
X1!
,
X@
1
,
X@
2
,
...
X@
n
]
Example:
E
3MR
}
Class 1,01,02,08,09
]
Outputs 1, 2, 8, and 9 are
assigned to room 3, which
named “Class 1”.
Save current ties as a room
preset
X1)
*
X1@
,
Rmm
X1)
•Spr
X1@]
Command character is a
comma.
Example:
3*9,
Rmm03•Spr09
]
Save current ties as preset 9
for room 3.
Recall room preset
X1)
*
X1@
.
Rmm
X1)
•Rpr
X1@]
Command character is a
period.
Directly write a room preset
E
+
X1)
*
X1@
P
X!
*
X@
!
X!
*
X@
%
X!
*
X@
$ ...
X!
*
X@
!
}
Enter as many ties as are
valid for this configuration.
The
! tie
,
& tie
, and
% tie
commands are all valid and
equivalent.
Rmm
X1)
•Spr
X1@]
Example:
+7*3P12*7&13*35$4*26%6*6!
Esc
Brackets are shown to
separate ties for clarity only.
Create preset 3 for room 7,
which ties audio input 12 to
output 7, video input 13 to
output 35, RGBHV input 4
to output 26, and video and
audio input 6 to output 6.
Rmm07•Spr03
]
N
X!
= Input number
01 – (maximum number of inputs for your model)
X@
= Output number
01 – (maximum number of outputs for your model)
X1)
= Room # (for room presets)
01 – 10 (Each can have up to 10 presets (
X1@
s) assigned.)
X1!
= Name
12 alphanumeric characters maximum
X1@
= Room preset #
01 – 10
Summary of Contents for CrossPoint 450 Plus 3248 HV
Page 1: ...CrossPoint 450 Plus Series MAV Plus series Large Scale Matrix Switchers 68 521 03 Rev B 11 09 ...
Page 4: ......
Page 10: ...Table of Contents cont d CrossPoint 450 Plus and MAV Plus Switchers Table of Contents vi ...
Page 32: ...Installation cont d CrossPoint 450 Plus and MAV Plus Switchers Installation 2 14 ...
Page 86: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 54 ...
Page 88: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 56 ...
Page 112: ...Programmer s Guide cont d CrossPoint 450 Plus and MAV Plus Switchers Programmer s Guide 4 24 ...
Page 183: ...B 15 CrossPoint 450 Plus and MAV Plus Switchers Reference Information Button label blanks ...