![Extron electronics CrossPoint 450 Plus 3248 HV User Manual Download Page 60](http://html.mh-extra.com/html/extron-electronics/crosspoint-450-plus-3248-hv/crosspoint-450-plus-3248-hv_user-manual_2456132060.webp)
Operation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Operation
3-28
2
.
Enter RGB Delay mode
: Press and
hold
the RGBHV button for
approximately 2 seconds until it blinks.
RGBHV
RGBHV
Press and hold the RGBHV
button until it blinks.
2 seconds
3
.
Select an output
: Press and release the Output 17 button.
17 18 19
1 2 3
O
U
T
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
25
9
26
10
27
11
I
N
Press and release the
Output 17 button.
The button lights.
The Input 1 through Input 10 buttons display the selected output's RGB delay.
Each lit input button indicates 0.5-second of delay.
In this example, the lit input buttons display 3.5 seconds of RGB delay.
3.5
3.0
2.5
2.0
1.5
1.0
0.5
N
The RGB delay is protected when front panel
lock
mode 2 is selected. You
can view the delay in
lock
mode 2, but not change it from the front panel. See
“Setting the front panel Locks (
modes)” on page 3-43.
If front panel
lock
mode 2 is selected and you try to perform step
4
, the actions
are ignored and the Enter, RGBHV, and Audio buttons flash.
4
.
Increase the delay
: Press and release the Esc (
>
) button once to increase the
RGB delay by a half second.
Press and release the Esc (
>
) button twice more to increase the RGB delay by
a whole second. Note the input button indications that change each time the
Esc (
>
) button is pressed and released.
The figure below show the result of pressing the Esc (
>
) button a total of three
times.
ESC
ESC
ESC
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
25
9
26
10
27
11
I
N
3.5
4.0
4.5
5.0
3.0
2.5
2.0
1.5
1.0
0.5
Press the Esc button to increase the RGB interval that is applied to switches to
the selected output by a half second per button push.
The Input 1 through Input 10 buttons display the selected output's RGB delay.
Each lit input button indicates 0.5-second of delay.
In this example, the lit input buttons display 5.0 seconds of RGB interval.
N
You can press and
hold
the Esc (
>
) or View (
<
) button to ramp the delay up or
down to the high or low limit.
Summary of Contents for CrossPoint 450 Plus 3248 HV
Page 1: ...CrossPoint 450 Plus Series MAV Plus series Large Scale Matrix Switchers 68 521 03 Rev B 11 09 ...
Page 4: ......
Page 10: ...Table of Contents cont d CrossPoint 450 Plus and MAV Plus Switchers Table of Contents vi ...
Page 32: ...Installation cont d CrossPoint 450 Plus and MAV Plus Switchers Installation 2 14 ...
Page 86: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 54 ...
Page 88: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 56 ...
Page 112: ...Programmer s Guide cont d CrossPoint 450 Plus and MAV Plus Switchers Programmer s Guide 4 24 ...
Page 183: ...B 15 CrossPoint 450 Plus and MAV Plus Switchers Reference Information Button label blanks ...